Engineering Papers⌕ Search

Engineering topics

Mumma, M. J.

Publications and source records attributed to Mumma, M. J..

At least 91 records · Page 5

Observations of the 10 micrometer natural laser emission from the mesospheres of Mars and Venus

Observations of the total flux and center to limb dependence of the nonthermal emission occurring in the cores of the 9.4 and 10.4 micrometers CO2 bands on Mars are compared to a theoretical model based on this mechanism. The model successfully reproduces the observed center to limb dependence of this emission, to within the limits imposed by the spatial resolution of the observations of Mars and Venus. The observed flux from Mars agrees closely with the prediction of the model; the flux observed from Venus is 74% of the flux predicted by the model. This emission is used to obtain the kinetic temperatures of the Martian and Venusian mesospheres. For Mars near 70 km altitude, a rotational temperature analysis using five lines gives T = 135 + or - 20 K. The frequency width of the emission is also analyzed to derive a temperature of 126 + or - 6 K. In the case of the Venusian mesosphere near 109 km, the frequency width of the emission gives T = 204 + or - 10 K.

Deming, D.↗

Modelling of the 10-micrometer natural laser emission from the mesospheres of Mars and Venus

The NLTE radiative transfer problem is solved to obtain the 00 deg 1 vibrational state population. This model successfully reproduces the existing center-to-limb observations, although higher spatial resolution observations are needed for a definitive test. The model also predicts total fluxes which are close to the observed values. The strength of the emission is predicted to be closely related to the instantaneous near-IR solar heating rate.

Deming, D.↗

Diode laser heterodyne observations of silicon monoxide in sunspots - A test of three sunspot models

Absorption features from the 8 micron SiO fundamental (upsilon = 1-0) and hot bands (upsilon = 2-1) have been observed in sunspots at sub-Doppler resolution using a ground-based tunable diode laser heterodyne spectrometer. The observed line widths suggest an upper limit of 0.5 km/s for the microturbulent velocity in sunspot umbrae. Since the silicon monoxide abundance is very sensitive to sunspot temperature, the measured equivalent widths permit an unambiguous determination of the temperature-pressure relation in the upper layers of the umbral atmosphere. In the region of SiO line formation (log P sub g = 3.0-4.5), the results support the sunspot model suggested by Stellmacher and Wiehr (1970).

Glenar, D. A.↗

Infrared heterodyne spectroscopy of seven gases in the vicinity of chlorine monoxide lines

Chlorine monoxide (ClO) is thought to play an important role in a photochemical cycle which causes the destruction of ozone in the earth's stratosphere. Since lines of the (1,0) fundamental of ClO lie near C-14O2-16, laser lines, IR heterodyne spectroscopy is potentially an important technique for monitoring the ClO abundance. However, due to the presence of lines from other trace atmospheric gases in this spectral range, the interpretation of such observations is ambiguous unless high resolution laboratory measurements support the identifications. Measured frequencies are reported for spectral lines of seven trace atmospheric gases which absorb near the C-14O2-16 laser transitions relevant to the detection of ClO by IR heterodyne spectroscopy.

Weaver, H. A.↗

Is there any chlorine monoxide in the stratosphere?

A ground-based search for stratospheric 35-ClO was carried out using an infrared heterodyne spectrometer in the solar absorption mode. Lines due to stratospheric HNO3 and tropospheric OCS were detected at about 0.2% absorptance levels, but the expected 0.1% lines of ClO in this same region were not seen. We find that stratospheric ClO is at least a factor of seven less abundant than is indicated by in situ measurements, and we set an upper limit of 2.3x10 to the 13th molecules/sq cm at the 95% confidence level for the integrated vertical column density of ClO. Our results imply that the release of chlorofluorocarbons may be significantly less important for the destruction of stratospheric ozone (O3) than is currently thought.

Mumma, M. J.↗

Is there any chlorine monoxide in the stratosphere?

A ground based search for the 856.50137/cm R(9.5) and for the 859.76765 R(12.5) transitions of stratospheric (Cl-35)O was made in the solar absorption mode using an infrared heterodyne spectrometer. Lines due to stratospheric HNO3 and tropospheric OCS were detected, at about 0.3% absorption levels. The expected lines of ClO in this same region were not detected, even though the optical depth of the ClO lines should be on the order of 0.2% using currently accepted ClO abundances. These infrared measurements suggest that stratospheric ClO is at least a factor of 7 less abundant than is indicated by indirect in situ fluorescence measurements, and the upper limit of 2.4x10 to the 13th power molecules/sq cm to the integrated column density of ClO is a factor of over 4 less than is indicted by microwave measurements. Results imply that the release of fluorocarbon precursors of ClO may be significantly less important for the destruction of stratospheric ozone than was previously thought.

Rogers, J. D.↗

Vibrational-Rotational Spectroscopy For Planetary Atmospheres, volume 1

Comprehensive information on the composition and dynamics of the varied planetary atmospheres is summarized. New observations resulted in new demands for supporting laboratory studies. Spectra observed from spacecraft used to interpret planetary atmospheric structure measurements, to aid in greenhouse and cloud physics calculations, and to plan future experiments are discussed. Current findings and new ideas of physicists, chemists, and planetry astronomers relating to the knowledge of the structure of things large and small, of planets and of molecules are summarized.

Mumma, M. J.↗

Speculations on the infrared molecular spectra of comets

No infrared vibration-rotation spectra have yet been seen for any comet, even though molecular emission features in the ultraviolet and visual regions are common, and gaseous matter is the dominant constituent of the coma. This is in part due to instrumental and atmospheric limitations, but also because non-LTE conditions prevail nearly everywhere throughout the coma and tails, leading to unusual spectra. Aspects of cometary physics and non-LTE spectroscopy are considered. Some aspects of the infrared signatures of cometary molecules are predicted.

Mumma, M. J.↗

Infrared heterodyne spectroscopy

Infrared heterodyne spectroscopy is an extremely useful tool for Doppler-limited studies of atomic and molecular lines in diverse astrophysical regions. The current state of the art is reviewed, and the analysis of CO2 lines in the atmosphere of Mars is outlined. Doppler-limited observations have enabled the discovery of natural laser emission in the mesosphere of Mars and the discovery of failure of local thermodynamic equilibrium near the surface of Mars.

Mumma, M. J.↗

Tunable diode-laser heterodyne spectrometer for remote observations near 8 microns

A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.

Glenar, D.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗

Discovery of natural gain amplification in the 10-micrometer carbon dioxide laser bands on Mars - A natural laser

Fully resolved intensity profiles of various lines in the carbon dioxide band at 10.4 micrometers have been measured on Mars with an infrared heterodyne spectrometer. Analysis of the line shapes shows that the Mars atmosphere exhibits positive gain in these lines. The detection of natural optical gain amplification enables identification of these lines as a definite natural laser.

Mumma, M. J.↗

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.↗

Optical considerations in infrared heterodyne spectrometer design

The optical design considerations for optimization of sensitivity, tunability, and versatility of an infrared heterodyne spectrometer are discussed using the GSFC CO2 laser heterodyne spectrometer optical front end as an example. Problems related to the coherent nature of the laser local oscillator beam (e.g., interference effects at edges of optical elements and at the beam combining beamsplitter) are described and proper beamsplitter design discussed. Optimum matching to the telescope is discussed. The severe effects of large central obscuration on the coherent telescope efficiency are described and steps to partially recover the lost system sensitivity are proposed. Measurements made with the GSFC 48 inch telescope (linear obscuration rate = 0.5) and the KPNO McMathe telescope (no obscuration) are given as examples.

Kostiuk, T.↗

RF spectrometers for heterodyne receivers

Several types of spectrometers developed for radio astronomy receivers which utilize RF filters, multiple oscillators and mixers, digital autocorrelators and acoustic/optic devices are considered. The RF spectrometer developed at GSFC to provide wide bandwidths (greater than 1 GHz) as well as high resolution (5MHz) is described. The 128 channel filter bank is divided into high and low resolution sections. The high resolution section is tunable by providing a second mixer ahead of the filter bank. This is necessary because infrared receivers which use gas lasers as local oscillators are only tunable to specific laser frequencies. To compensate for astronomical Doppler shifts and molecule frequency differences a second local oscillator and mixer is needed. A diagram of the RF section of the filter bank is shown. The RF spectrometer is shown to be the best means of achieving ultra-wide bandwidths for infrared heterodyne receivers. For high resolution with a large number of channels, the acousto/optical spectrometer is the principle instrument, particularly for balloon or space flight applications.

Buhl, D.↗

Vibrationally excited silicon monoxide masers

Published data on a select group of SiO maser sources have been analyzed for velocity variations as a function of phase. No apparent correlation was found to a level of about 2 km/s. This places constraints on the location of the maser molecules. Such a correlation should be present at some level. The implications for future high resolution infrared measurements are discussed.

Buhl, D.↗