Engineering PapersβŒ• Search

Engineering topics

Mueller, P.

Publications and source records attributed to Mueller, P..

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗

The Beta-decay Paul Trap Mk IV: Design and commissioning

Here, the Beta-decay Paul Trap is an open-geometry, linear trap used to measure the decays of 8 Li and 8 B to search for a tensor contribution to the weak interaction. In the latest 8 Li measurement of Burkey et al. (2022), Ξ² scattering was the dominant experimental systematic uncertainty. The Beta-decay Paul Trap Mk IV reduces the prevalence of Ξ² scattering by a factor of 4 through a redesigned electrode geometry and the use of glassy carbon and graphite as electrode materials. The trap has been constructed and successfully commissioned with 8 Li in a new data campaign that collected 2.6 million triple coincidence events, an increase in statistics by 30% with 4 times less Ξ² scattering compared to the previous 8 Li data set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Improved Tensor Current Limit from 8 B 𝛽 Decay Including New Recoil-Order Calculations

A precision measurement of the 𝛽 + decay of 8 B was performed using the Beta-decay Paul Trap to determine the π›½βˆ’πœˆ angular correlation coefficient π‘Ž π›½β’πœˆ . The experimental results were combined with new ab initio symmetry-adapted no-core shell-model calculations to yield the second-most precise measurement from Gamow-Teller decays, π‘Ž π›½β’πœˆ = βˆ’0.3345 Β± 0.001⁒9 stat Β± 0.002⁒1 syst . This value agrees with the standard model value of βˆ’1/3 and improves uncertainties in 8 B by nearly a factor of 2. By combining results from 8 B and 8 Li , a tight limit on tensor current coupling to right-handed neutrinos was obtained. A recent global evaluation of all other precision 𝛽 decay studies suggested a nonzero value for right-handed neutrino coupling in contradiction with the standard model at just above 3⁒𝜎. Finally, the present results are of comparable sensitivity and do not support this finding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementing an electronic sideband offset lock for isotope shift spectroscopy in radium

We demonstrate laser frequency stabilization with at least 6 GHz of offset tunability using an in-phase/quadrature (IQ) modulator to generate electronic sidebands (ESB) on a titanium sapphire laser at 714 nm and we apply this technique to perform isotope shift spectroscopy of 226 Ra and 225 Ra. By locking the laser to a single resonance of a high finesse optical cavity and adjusting the lock offset, we determine the frequency difference between the magneto-optical trap (MOT) transitions in the two isotopes to be 2630.0 Β± 0.3 MHz, a factor of 29 more precise than the previously available data. Using the known value of the hyperfine splitting of the 3 P 1 level, we calculate the isotope shift for the 1 S 0 to 3 P 1 transition to be 2267.0 Β± 2.2 MHz, a factor of 8 more precise than the best available value. Our technique could be applied to countless other atomic systems to provide unprecedented precision in isotope shift spectroscopy and other relative frequency comparisons.

47 OTHER INSTRUMENTATION↗

Angular Correlations in the Ξ² Decay of B 8 : First Tensor-Current Limits from a Mirror-Nucleus Pair

We present the first measurement of the α–β–ν angular correlation in the Gamow-Teller Ξ² + decay of 8 B. This was accomplished using the Beta-decay Paul Trap, expanding on our previous work on the Ξ² – decay of 8 Li. The 8 B result is consistent with the V – A electroweak interaction of the standard model and, on its own, provides a limit on the exotic right-handed tensor current relative to the axial-vector current of |C T /C A | 2 < 0.013 at the 95.5% confidence level. This represents the first high-precision angular correlation measurements in mirror decays and was made possible through the use of an ion trap. Here, by combining this 8 B result with our previous 8 Li results, we demonstrate a new pathway for increased precision in searches for exotic currents.

6 ≀ A ≀ 19β†—

Determination of the $^8\mathrm{B}$ neutrino energy spectrum using trapped ions

We report the Ξ² + decay of 8 B provides the dominant source of solar neutrinos above 2 MeV. Consequently, experiments that detect neutrinos from the sun require an accurate determination of the 8 B neutrino energy spectrum. In this work, the Ξ² -decay Paul trap surrounded by double-sided silicon strip detectors was utilized to precisely measure the decay products of trapped 8 B ions. The results were used to determine the 8 Be final-state distribution and to reconstruct the neutrino energy spectrum. This measurement using trapped ions is the first of its kind and puts the neutrino energy spectrum on much firmer footing by discriminating between recently reported values for the maximum of the final-state distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Limit on Tensor Currents in the Weak Interaction from Li 8 Ξ² Decay

Here, the electroweak interaction in the standard model is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this Letter, we present the most precise measurement of tensor currents in the low-energy regime by examining the $Ξ²-\bar{Ξ½}$ correlation of trapped 8 Li ions with the Beta-decay Paul Trap. We find $a_{Ξ²\barΞ½}$ = - 0.3325 Β± 0.0013 stat Β± 0.0019 syst at 1Οƒ for the case of coupling to right-handed neutrinos (C T = -C$^{'}_{T}$), which is consistent with the standard model prediction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution spectroscopy of neutral Yb atoms in a solid Ne matrix

Here, we present an experimental and theoretical study of the absorption and emission spectra of Yb atoms in a solid Ne matrix at a resolution of 0.025 nm. Five absorption bands were identified as due to transitions from the 4 f 14 5 d 0 6 s 2 1 S 0 ground-state configuration to 4 f 14 5 d 0 6 s 6 p and 4 f 13 5 d 1 6 s 2 configurations. The two lowest-energy bands were assigned to outer-shell transitions to 6 s 6 p 3 P 1 and 1 P 1 atomic states and displayed the structure of a broad doublet and an asymmetric triplet, respectively. The remaining three higher-frequency bands were assigned to inner-shell transitions to distinct J = 1 states arising from the 4 f 13 5 d 1 6 s 2 configuration and were highly structured with narrow linewidths. A classical simulation was performed to identify the stability and symmetry of possible trapping sites in the Ne crystal. It showed that the overarching 1 + 2 structure of the high-frequency bands could be predominantly ascribed to crystal-field splitting in the axial field of a 10-atom vacancy of C 4 v symmetry. Their prominent substructures were shown to be manifestations of phonon sidebands associated with the zero-phonon lines on each crystal-field state. Unprecedented for a metal–rare-gas system, resolution of individual phonon states on an allowed electronic transition was possible under excitation spectroscopy which reflects the semiquantum nature of solid Ne. In contrast to the absorption spectra, emission spectra produced by steady-state excitation into the 1 P 1 absorption band consisted of simple, unstructured fluorescence bands.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectroscopic study and lifetime measurement of the 6d7p 3 F 2 o state of radium

We report a method for the precision measurement of the oscillator strengths and the branching fractions of the decay channels of the 6d7p 3 F 2 o state in 226 Ra. Here, this method exploits a set of metastable states present in Ra, allowing a measurement of the oscillator strengths that does not require knowledge of the number of atoms in the atomic beam. We measure the oscillator strengths and the branching fractions for decays from the 6d7p 3 F 2 o state to the 7s6d 3 D 1 , 7s6d 3 D 2 , and 7s6d 1 D 2 states and constrain the branching fraction to the 7s6d 3 D 3 state to be less than 0.4% (68% confidence limit). The lifetime of the 3 F 2 o state is determined to be 15 Β± 4 ns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atmospheric 81 Kr as an Integrator of Cosmic-Ray Flux on the Hundred-Thousand-Year Time Scale

The atmospheric abundance of 81 Kr is a global integrator of cosmic rays. It is insensitive to climate shifts, geographical variations, and short-term solar cycle activity, making it an ideal standard to test models of cosmic-ray flux on the time scale of 10 5 years. In this work, we present the first calculation of absolute 81 Kr production rates in the atmosphere, and a measurement of the atmospheric 81 Kr/Kr abundance via the Atom Trap Trace Analysis method. The measurement result significantly deviates from previously reported values. The agreement between measurement and model prediction supports the current understanding of the production mechanisms. Additionally, the calculated 81 Kr atmospheric inventory over the past 1.5 Myr provides a more accurate input function for radiokrypton dating.

58 GEOSCIENCES↗

Neutron decay correlations in the Nab experiment

The Nab experiment will measure the correlation a between the momenta of the beta particle and antineutrino in neutron decay as well as the Fierz term b which distorts the beta spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid processing of 85 Kr/Kr ratios using Atom Trap Trace Analysis

In this paper, we report a methodology for measuring 85 Kr/Kr isotopic abundances using Atom Trap Trace Analysis (ATTA) that increases sample measurement throughput by over an order of magnitude to six samples per 24 h. The noble gas isotope 85 Kr (half-life = 10.7 years) is a useful tracer for young groundwater in the age range of 5–50 years. ATTA, an efficient and selective laser-based atom counting method, has recently been applied to 85 Kr/Kr isotopic abundance measurements, requiring 5–10 ΞΌL of krypton gas at STP extracted from 50 to 100 L of water. Previously, a single such measurement required 48 h. In conclusion, our new method demonstrates that we can measure 85 Kr/Kr ratios with 3–5% relative uncertainty every 4 h, on average, with the same sample requirements.

54 ENVIRONMENTAL SCIENCES↗

Setting a limit on anthropogenic sources of atmospheric 81 Kr through Atom Trap Trace Analysis

In this study, we place a 2.5% limit on the anthropogenic contribution to the modern abundance of 81 Kr/Kr in the atmosphere at the 90% confidence level. Due to its simple production and transport in the terrestrial environment, 81 Kr (half-life = 230,000 years) is an ideal tracer for old water and ice with mean residence times in the range of 105–106 years. In recent years, 81 Kr-dating has been made available to the earth science community thanks to the development of Atom Trap Trace Analysis (ATTA), a laser-based atom counting technique. Further upgrades and improvements to the ATTA technique now allow us to demonstrate 81 Kr/Kr measurements with relative uncertainties of 1% and place this new limit on anthropogenic 81 Kr. As a result of this limit, we have removed a potential systematic constraint for 81 Kr-dating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COHERENT Experiment: current status

The COHERENT Collaboration is realizing a long term neutrino physics research program. The main goals of the program are to detect and study elastic neutrino-nucleus scattering (CEΞ½NS). This process is predicted by Standard Model but it has never been observed experimentally because of the very low energy of the recoil nucleus. COHERENT is using different detector technologies: CsI[Na] and NaI scintillator crystals, a single-phase liquid Ar and a Ge detectors. The placement of all the detector setups is in the basement of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The current status of the COHERENT experimental program is presented.

36 MATERIALS SCIENCE↗

Development of Thick-Film Thermoelectric Microcoolers Using Electrochemical Deposition

Advanced thermoelectric microdevices integrated into thermal management packages and low power, electrical source systems are of interest for a variety of space and terrestrial applications. By shrinking the size of the thermoelements, or legs, of these devices, it becomes possible to handle much higher heat fluxes, as well as operate at much lower currents and higher voltages that are more compatible with electronic components. The miniaturization of state-of-the-art thermoelectric module technology based on Bi2Te3 alloys is limited due to mechanical and manufacturing constraints for both leg dimensions (100-200 gm thick minimum) and the number of legs (100-200 legs maximum). We are investigating the development of novel microdevices combining high thermal conductivity substrate materials such as diamond, thin film metallization and patterning technology, and electrochemical deposition of thick thermoelectric films. It is anticipated that thermoelectric microcoolers with thousands of thermocouples and capable of pumping more than 200 W/sq cm over a 30 to 60 K temperature difference can be fabricated. In this paper, we report on our progress in developing an electrochemical deposition process for obtaining 10-50 microns thick films of Bi2Te3 and its solid solutions. Results presented here indicate that good quality n-type Bi2Te3, n-type Bi2Te(2.95)Se(0.05) and p-type Bi(0.5)Sb(1.5)Te3 thick films can be deposited by this technique. Some details about the fabrication of the miniature thermoelements are also described.

Fleurial, J.-P.β†—