Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imagery with a Si:Bi 16 x 16 array

A description of the design and performance of an imaging spectrometer intended for operation in the 7 to 14 micron wavelength range is presented. It is based upon a 16 by 16 element Si:Bi hybrid array, a circular variable filter wheel, and a microcomputer data acquisition system. The spatial-spectral photometric performances were evaluated in the laboratory as well as field tested at astronomical observatories. The performance characteristics of the system are presented as well as laboratory and astronomical images.

Goebel, J. H.↗

Narrow band imagery in the 8-14 micron spectral region

The problem of deconvolution of the point source response function (PSF) for two-dimensional imaging infrared arrays is addressed. A variety of phenomena can lead to PSF degradation, ranging from atmospheric turbulence to the array itself. The maximum entropy algorithm is used to demonstrate that substantial image quality improvements are possible in the case of a PSF which is degraded by electronic rather than optical smearing. This result implies that IR arrays need not have perfect or even very good pixel-pixel crosstalk rejection ratios for use in astronomy.

Goebel, J. H.↗

Photometric imaging near infrared spectrometer

A description of the design and performance of an imaging spectrometer intended for operation in the seven to fourteen micrometer wavelength range is presented. It is based upon a sixteen by sixteen element Si:Bi hybrid array, a circular variable filter wheel, and a microcomputer data acquisition system. The spatial-spectral photometric performances have been evaluated in the laboratory as well as field tested at astronomical observatories. The performance characteristics of the system are presented as well as laboratory and astronomical images.

Goebel, J. H.↗