Engineering PapersSearch

Engineering topics

Moseley, Harvey

Publications and source records attributed to Moseley, Harvey.

36 records · Page 2

Fabrication of MEMS Microshutter Arrays for Cryogenic Applications

Two-dimensional MEMS microshutter arrays are being developed for use as a high contrast field selector for the Near Infrared Spectrograph (NIRSpec) on the James Webb Space Telescope (JWST). We present details of microshutter array fabrication and give results of work done to optimize the flatness of microshutter elements through film stress control for both room temperature and cryogenic (35K) operation.

Denis Kevin

Large Format Detector Arrays for Astrophysics

Improvements in detector design and advances in fabrication techniques has resulted in devices which can reach fundamental sensitivity limits in many cases. Many pressing astrophysical questions require large arrays of such sensitive detectors. I will describe the state of far infrared through millimeter detector development at NASA/GSFC, the design and production of large format arrays, and the initial deployment of these powerful new tools.

Moseley, Harvey

Comparison of Spitzer/IRAC Galactic Center Mid-IR Survey Results with X-ray and Radio Emission Due to High-Energy Processes in the Central 100 Parsecs

We compare the results of a small region from our 3.6 - 8.0 micron Spitzer/IRAC imaging survey of 2 x 1.5 deg around the Galactic Center with x-ray and radio emission due to high energy processes. The region we studied covers 100 x 100 parsecs, and was chosen to include a rich collection of sources, including Sgr A* and the bright Sgr AWest infrared/radio source complex, the non-thermal radio filaments and the thermal: radio arches. In a 40 x 40 parsec subset of that region we also make a preliminary analysis of the correlation between approx.2300 x-ray sources identified by Muno et al. (2003) and 20,000 infrared sources from our survey. We also investigate the correlation between infrared and radio emission in the large-scale structures including the thermal radio arches and non-thermal radio filaments. We set constrictions on the synchrotron spectrum observed at radio and millimeter wavelengths extrapolated to 8 micons, and set limits on the midinfrared variability of Sgr A* during and after the coordinated multi-wavelength observing campaign in September 2004.

Gezari, D. Y.

MEMS Microshutter Arrays for James Webb Space Telescope

MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use as an aperture array for a Near-Infrared Spectrometer (NirSpec). The instruments will be carried on the James Webb Space Telescope (JWST), the next generation of space telescope after Hubble Space Telescope retires. The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast, Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. Light shields are made on to each shutter for light leak prevention so to enhance optical contrast, Shutters are actuated magnetically, latched and addressed electrostatically. The shutter arrays are fabricated using MEMS technologies.

Li, Mary J.

Low Temperature (30 K) TID Test Results of a Radiation Hardened 128 Channel Serial-to-Parallel Converter

This viewgraph presentation reviews the low temperature, Total Ionizing Dose (TID) tests of radiation hardened serial to parallel converter to be used on the James Webb Space Telescope. The test results show that the original HV583 level shifter - a COTS part -was not suitable for JWST because the supply currents exceeded specs after 20 krad( Si) .The HV584 - functionally similar to the HV583 -was designed using RHBD approach that reduced the leakage currents to within acceptable levels and had only a small effect on the level-shifted output voltage.

Meyer, Stephen

Maximizing Science Capability for Far-Infrared Space Missions

The far-infrared and submillimeter region (20 microns-800 microns) has perhaps the greatest potential of all wavelengths for advancement in astronomy. When viewed in terms of the cosmic backgrounds, the far-IR is extremely important: half of the total luminosity in the Universe is emitted at rest wavelengths approximately 80-100 microns. At the highest known galaxy redshifts (z approximately equal to 6) this energy is redshifted to approximately 600 microns. Existing and planned missions have a broad range of capabilities, defined in terms of their spectral coverage, spectral resolution, angular resolution, mapping speed, and sensitivity. In this 5-dimensional parameter space, the far-IR is substantially be-hind most other wavelength bands. The opportunity for future missions with great discovery potential is evident. Such missions will be well-suited to answering fundamental questions about the history of energy release in the Universe, the formation and evolution of galaxies, and formation of stellar and protoplanetary systems. We discuss the parameter space that can be filled by a few well-chosen space missions, specifically a submillimeter all-sky survey and a far-IR to submillimeter observatory. Ultimately, a long baseline submillimeter interferometer is necessary to provide sensitivity and angular resolution.

Benford, Dominic

Arrays of High Performance Thermal Detectors

Thermal detectors have historically been the sensors of choice for applications where photoconductive or photovoltaic detectors are unavailable. While they have the advantage of broad wavelength coverage, a primary disadvantage has been sensitivity; at a given operating temperature, bolometers are typically much less sensitive than photodetectors. The development of cryogenic bolometers has resulted in thermal detectors which can reach fundamental sensitivity limits. When operated at temperatures below 0.3 K these devices can provide background-limited sensitivity for cryogenic imaging and spectroscopy in space. The past decade has seen a rapid growth in sensitivity and array format in cryogenic bolometers. Micromachining technology, combined with advances in superconducting electronics, provides a strong technological base for future developments. I will describe the present state of development of low-temperature thermal detectors, and the possible extension of this technology to higher temperature operation.

Moseley, Harvey

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey

Slit Function Measurement of An Imaging Spectrograph Using Fourier Transform Techniques

Knowledge of a spectrograph slit function is necessary to interpret the unresolved lines in an observed spectrum. A theoretical slit function can be calculated from the sizes of the entrance slit, the detector aperture when it functions as an exit slit, the dispersion characteristic of the disperser, and the point spread function of the spectrograph. A measured slit function is preferred to the theoretical one for the correct interpretation of the spectral data. In a scanning spectrometer with a single exit slit, the slit function is easily measured. In a fixed grating/or disperser spectrograph, illuminating the entrance slit with a near monochromatic light from a pre-monochrmator or a tunable laser and varying the wavelength of the incident light can measure the slit function. Even though the latter technique had been used successfully for the slit function measurements, it had been very laborious and it would be prohibitive to an imaging spectrograph or a multi-object spectrograph that has a large field of view. We explore an alternative technique that is manageable for the measurements. In the proposed technique, the imaging spectrograph is used as a detector of a Fourier transform spectrometer. This method can be applied not only to an IR spectrograph but also has a potential to a visible/UV spectrograph including a wedge filter spectrograph. This technique will require a blackbody source of known temperature and a bolometer to characterize the interferometer part of the Fourier Transform spectrometer. This pa?er will describe the alternative slit function measurement technique using a Fourier transform spectrometer.

Park, Hongwoo

Microshutters Arrays for the JWST Near Infrared Spectrometer

The Near Infrared Spectrograph (NIRSpec) for the James Webb Space Telescope (JWST) is an essential instrument for measuring the number and density evolution of galaxies following the epoch of initial formation. The NIRSpec is a multi-object spectrograph, allowing simultaneous observation of more than 100 candidate high redshift galaxies. A critical element of the instrument is the programmable field selector, the Microshutter Array. The system consists of four 175 x 384 arrays of individually openable shutters, close packed on a 100 x 200 micron pitch, which allow selection of over 200 candidate objects over the 3 min x 3 min field of the NIRSpec. We will describe the development, production, and test of this critical element of the NIRSpec.

Moseley, Harvey

A Two-Dimensional, Semiconducting Bolometer Array for HAWC

The Stratospheric Observatory For Infrared Astronomy's (SOFIA's) High resolution Airborne Wideband Camera (HAWC) will use an ion-implanted silicon bolometer array developed at NASA s Goddard Space Flight Center (GSFC). The GSFC Pop-Up Detectors (PUDs) use a unique folding technique to enable a 12 x 32 element closepacked array of bolometers with a filling factor greater than 95%. The HAWC detector uses a resistive metal film on silicon to provide frequency independent, approx. 50% absorption over the 40 - 300 micron band. The silicon bolometers are manufactured in 32-element rows within silicon frames using Micro Electro Mechanical Systems (MEMS) silicon etching techniques. The frames are then cut, "folded", and glued onto a metallized, ceramic, thermal bus "bar". Optical alignment using micrometer jigs ensures their uniformity and correct placement. The rows are then stacked side-by-side to create the final 12 x 32 element array. A kinematic Kevlar suspension system isolates the 200 mK bolometer cold stage from the rest of the 4K detector housing. GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The Junction Field Effect Transistor (JFET) preamplifiers for all the signal channels operate at 120 K, yet they are electrically connected and located in close proximity to the bolometers. The JFET module design provides sufficient thermal isolation and heat sinking for these, so that their heat is not detected by the bolometers. Preliminary engineering results from the flight detector dark test run are expected to be available in July 2004. This paper describes the array assembly and mechanical and thermal design of the HAWC detector and the JFET module.

Voellmer, George M.

SAFIRE: Far-Infrared Imaging Spectroscopy with SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 microns-655microns, with spectral resolving power of approx. 1500 (200 kilometers per second). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors.

Benford, Dominic

Probing Galaxy Formation and Evolution with Space Born Sub-Millimeter Telescopes

A major unresolved question in cosmology is how the complex system of galaxies we see in the present universe evolved from an almost perfectly smooth beginning. Multiwavelength observations of galaxies have revealed that a significant fraction of their UV-visible starlight is absorbed and reradiated by dust at infrared JR) and submillimeter wavelengths. The cumulative IR-submm. emission from galaxies since the epoch of recombination, the cosmic IR background, has recently been recorded by the COBE satellite. The COBE observations in combination with recent submm surveys conducted with the SCUBA on the 15 m JCMT have shown that most of the radiation from star formation that has taken place in the early stages of galaxy evolution is reradiated by dust at submm wavelengths. Therefore, submm telescopes offer a unique probe of the early stages of galaxy formation and evolution. This talk will: (1) consider the impact of telescope diameter on the depth of the survey (what redshift can be probed) at different wavelengths; (2) discuss the relative scientific merits of high-resolution narrow-field surveys versus lower resolution deep surveys; and (3) show how both strategies offer complementary information crucial to our understanding of the structure and evolution of galaxies in the universe.

Dwek, Eli

Microcalorimetry: The First Two Decades

Our group at GSFC began experimental and theoretical work on microcalorimetry almost twenty years ago, in August of 1982. Over the next 10 months, we completed the initial demonstration of a Si impurity thermometer-based calorimeter as an X-ray spectrometer. This successful demonstration resulted in the development by many investigators of scientific applications for microcalorimeters, ranging from optical spectroscopy to dark matter detection to particle physics applications. Many new technical approaches for cryogenic detectors were proposed by investigators and have been developed. In this presentation, I will describe the early development of microcalorimeters at GSFC and University of Wisconsin and the subsequent rapid growth of this work around the world The key milestones in the early development were the initial spectroscopy demonstrations and the selection of XRS, our microlcalorimeter-based instrument for the Advanced X-ray Astrophysics Facility (AXAF) and ultimately for ASTRO-E. An additional key event was the development of the direct detection of dark matter experiment and the formation of the Center for Particle Astrophysics. Both of these programs provided long term support for this technology in its precarious early days. A major additional technical step in the development of detectors was the demonstration of devices based on superconducting transition edge sensors (TES). These detectors promised (and have delivered) improved energy resolution and higher event rate capabilities. They couple naturally to SQUIDS, which operate well at the low temperatures where the detectors must operate. The past two decades have taken microcalorimeters from their infancy to applications in real experiments. I will provide an overview of the early development of the devices and review the breadth of the present technology and applications.

Moseley, Harvey

Microshutter Array Development for the Multi-Object Spectrograph for the New Generation Space Telescope, and Its Ground-based Demonstrator

The 6.5-m NASA/ESA/Canada New Generation Space Telescope to be operated at the L2 Lagrangian point will require a multi-object spectrograph (MOS) operating from 1 to 5 microns. Up to 3000 targets will be selected for simultaneous spectroscopy using a programmable cryogenic (approx. 35K) aperture array, consisting of a mosaic of arrays of micromirrors or microshutters. We describe the current status of the GSFC microshutter array development. The 100 micron square shutters are opened magnetically and latched open or closed electrostatically. Selection will be by two crossed one-dimensional addressing circuits. We will demonstrate the use of a 512 x 512 unit array on a ground-based IR MOS which will cover 0.6 to 5 microns, and operate rapidly to include spectroscopy of gamma ray burst afterglows.

Woodgate, Bruce E.

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey

IRC +10420 - A cool hypergiant near the top of the H-R diagram

New observations were obtained for the OH/IR star IRC +10420, including optical/infrared imaging, spectroscopy, polarimetry, and photometry. The observations, which indicate a very rich and complex circumstellar environment for the star. A model for IRC +10420 star is proposed, in which a true core-burning supergiant is surrounded by a rotating equatorial disk of gas and dust that is viewed from about midway above the plate.

Jones, Terry J.

Design considerations for 0.1K bolometers

Bolometers operating at low temperatures (T greater than 0.3 K) are the best candidate for far infrared (lambda greater than or = 120 microns) and submillimeter detection from cold orbiting telescopes. The limits of sensitivity for such devices have been studied (Mather, 1983). Based on this work, we conclude that excellent sensitivity is possible given careful detector design. We have designed and are fabricating bolometers for operation at low temperatures. The crucial components in detector design are (1) heat capacity, (2) temperature sensing, and (3) absorption of infrared radiation. In this presentation, we discuss the choice of materials and fabrication techniques we have made in the interest of maximum sensitivity. In order that optimization of detector performance be reasonably easy to carry out, we have attempted to use conventional fabrication techniques wherever possible (photolithography, wire bonding). The use of such procedures allows us to make design changes on short time scales, which is essential in achieving optimal performance.

Moseley, Harvey