Engineering Papers⌕ Search

Engineering topics

Moschini, Giuliano

Publications and source records attributed to Moschini, Giuliano.

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery

Cyberknife (Accuracy Inc., Ca) is a robotic radio-surgery system that includes a compact 6 MV linac delivering up to 800 cGy per minute, and an automate arm to aim at any part of the body from any angle. An essential tool is the guidance system based on x-ray imaging cameras located on supports around the patient. A Cyberknife system has been operational at the Vicenza (Italy) Hospital for years and is mainly employed for treating benign and malignant tumors, and Arterior-Venous Malformations. In radiation therapy, delivery of high doses to targets that move with respiration is challenging because of possible spatial inaccuracies. The purpose of this work was to estimate the accuracy of the prediction algorithm used to compensate for system latency in a real-time respiratory tracking system. We have analyzed respiratory signals of 30 patients who had lung or liver Cyberknife treatments. The 'Synchrony'(Accuracy Inc.) motion tracking system we use is based on the correlation between the position of LED markers, detected in real time, and the position of internal markers, sampled through x-ray imaging. The position of the external LED signals, though read in real time, must be predicted to compensate for a few hundred ms time lag in the feedback loop that redirects the beam to the current target position. The respiratory signals were described by employing their frequency power spectrum, as recently proposed by other authors. Prediction errors above 1.5 mm, lasting for periods longer than 5 seconds were observed for irregular breathers. These episodes correlate to the presence of a bimodal distribution in the power spectral density, and of very low frequencies contribution. A more refined approach would include a personalized choice of the prediction algorithm based on the very first minutes of treatment. Patient training aimed at reducing breathing irregularities might also result in improved spatial accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Lanthanum Bromide Detector and a New Conception Collimator for Radiopharmaceuticals Molecular Imaging in Oncology

We have realized and tested a new-design compact gamma camera for high resolution SPET (Single Photon Emission Tomography), and small animals' radio-pharmaceutical molecular imaging. The camera is based on a 'continuous' Lanthanum tri-Bromide crystal, and a new Low Energy (LE) collimator. The crystal is interfaced to a 2x2 array of Hamamatsu-H8500 position sensitive photo-multipliers. The lead collimator features parallel hexagonal 1.0 mm holes, 18 mm length, 0.2 mm septa and 10x10 cm{sup 2} detection area. It was newly designed to fully exploit the high spatial resolution a Lanthanum crystal may provide. To better evaluate its role, we have compared our camera to three other systems with similar crystals and photomultipliers, but employing traditional collimators, either pinhole or parallel. The new camera seems to be complementary to pinhole systems and shows a very attractive trade-off between spatial resolution and detection area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗