Engineering Papers⌕ Search

Engineering topics

Morley, D. J.

Publications and source records attributed to Morley, D. J..

A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors

Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a {sup 90}Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging the inside of thick structures using cosmic rays

The authors present here a new method to image reinforcement elements inside thick structures and the results of a demonstration measurement performed on a mock-up wall built at Los Alamos National Laboratory. The method, referred to as “multiple scattering muon radiography”, relies on the use of cosmic-ray muons as probes. The work described in this article was performed to prove the viability of the technique as a means to image the interior of the dome of Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage sites and among the highest profile buildings in existence. Its result shows the effectiveness of the technique as a tool to radiograph thick structures and image denser object inside them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Storage of Ultracold Neutrons in the Magneto-Gravitational Trap of the UCN Experiment

The UCN experiment is designed to measure the lifetime n of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provides a background holding field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time store of the trap by storing UCN for various times and counting the survivors. The data are consistent with a single exponential decay, and we find store = 860 19 s, within 1 of current global averages for n. The storage time with the holding field deactivated is found to be store = 470 160 s; this decreased storage time is due to the loss of UCN, which undergo Majorana spin flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

Salvat, D. J.↗

Qualitative comparison of bremsstrahlung X-rays and 800 MeV protons for tomography of urania fuel pellets

We present an assessment of x-rays and proton tomography as tools for studying the time dependence of the development of damage in fuel rods. We also show data taken with existing facilities at Los Alamos National Laboratory that support this assessment. Data on surrogate fuel rods have been taken using the 800 MeV proton radiography (pRad) facility at the Los Alamos Neutron Science Center (LANSCE), and with a 450 keV bremsstrahlung X-ray tomography facility. The proton radiography pRad facility at LANSCE can provide good position resolution (<70 {mu}m has been demonstrate, 20 {mu}m seems feasible with minor changes) for tomography on activated fuel rods. Bremsstrahlung x-rays may be able to provide better than 100 {mu}m resolution but further development of sources, collimation, and detectors is necessary for x-rays to deal with the background radiation for tomography of activated fuel rods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The neutron imaging diagnostic at NIF (invited)

A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗