Engineering Papers⌕ Search

Engineering topics

Moore, F. B.

Publications and source records attributed to Moore, F. B..

Mechanisms of Orthostatic Tolerance Improvement Following Artificial Gravity Exposure Differ Between Men and Women

We recently determined that a short exposure to artificial gravity (AG) improved the orthostatic tolerance limit (OTL) of cardiovascularly deconditioned subjects. We now seek to determine the mechanisms of that improvement in these hypovolemic men and women. Methods. We determined the orthostatic tolerance limit (OTL) of 9 men and 8 women following a 90 min exposure to AG compared to 90 min of head down bed rest (HDBR). In both cases (21 days apart), subjects were made hypovolemic (low salt diet plus 20 mg intravenous furosemide). Orthostatic tolerance was determined from a combination of head up tilt and increasing lower body negative pressure until presyncope. Mean values and correlations with OTL were determined for heart rate, blood pressure, stroke volume, cardiac output and peripheral resistance (Finometer), cerebral artery blood velocity (DWL), partial pressure of carbon dioxide (Novametrics) and body segmental impedance (UFI THRIM) were measured during supine baseline, during OTL to presyncope and during supine recovery Results. Orthostatic tolerance of these hypovolemic subjects was significantly greater on the day of AG exposure than on the HDBR day. Regression of OTL on these variables identified significant relationships on the HDBR day that were not evident on the AG day: resting TPR correlated positively while resting cerebral flow correlated negatively with OTL. On both days, women's resting stroke volume correlated positively with orthostatic tolerance. Higher group mean values of stroke volume and cerebral artery flow and lower values of blood pressure, peripheral vascular and cerebrovascular resistance both at control and during OTL testing were observed on the AG day. Even though regression of OTL on resting stroke volume was significant only in women, presyncopal stroke volume reached the same level on each day of study for both men and women while the OTL test lasted 30% longer in men and 22% longer in women. Cerebral artery flow appeared to follow stroke volume and absolute values of cerebral flow did not correlate with the development of presyncope. Women responded to AG exposure with elevated cerebral flow at resting control and throughout the OTL test, implying a loss of autoregulation in deconditioned (hypovolemic) women following AG exposure. Conclusions. Before countermeasures to space flight cardiovascular deconditioning are established, gender differences in cardiovascular responses to orthostatic stress, in general, and to orthostatic stress following exposure to artificial gravity, in particular, need to be determined. Since, in both men and women, a single, acute bout of AG exposure improved orthostatic tolerance, the feasibility of short exposures to AG during longer spaceflights or prior to entry into a gravity (Earth or Mars) environment, should be explored. Given the known beneficial effects of AG on other organ systems, the present study indicates that the positive effects of AG on cardiac stroke volume make AG a likely candidate for maintaining cardiovascular conditioning.

Evans, J. M.↗

Exercise Increases the Cardiovascular Stimulus Provided by Artificial Gravity

We investigated fluid shifts and regulatory responses to variations of posture, exercise, Gz level and radius of rotation in subjects riding NASA Ames 20G centrifuge. Results are from 4 protocols that address radius and exercise effects only. Protocol A: After 10 min supine control, 12 healthy men (35 plus or minus 9 yr, 82.8 plus or minus 7.9 kg) were exposed to rotational 1 Gz (2.5 m radius) for 2 min followed by 20 min alternating between 1 and 1.25 Gz. Blood samples were taken pre and post spin. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 8.3 m. Protocol D: Same as B but at 8.3 m. The 8 subjects who completed all protocols, increased heart rate (HR) from control, on average, by: A: 5, B: 39, C: 11, D: 44 bpm. For thoracic fluid volume, (bioimpedance), the 8 subjects changed from control, on average: A: -394, B: -548, C: -537, D: -708 mL. For thigh fluid volume, changes from control, on average, were: A: -137, B: 129, C: -75, D: 159 mL. Hematocrit changes from control were: A: 2.3, B: 3.5, C: 2.3, D: 4.3 %. Radius effects were mild and included greater loss of fluid from the thorax, less fluid loss from the thigh and increased heart rate at the longer radius. Pre-acceleration exercise effects were more dramatic and included additional loss of fluid from the chest, increased fluid volume of the thigh, increased hematocrit and greater heart rate increases. We propose that short bouts of intense exercise can be used to magnify the cardiovascular stress delivered by artificial gravity (AG) training and the combination of AG with exercise training can be fine-tuned to preserve orthostatic tolerance of astronauts during spaceflight.

Howarth, M. S.↗

Thoracic Impedance as a Potential Indicator of Gz-induced Presyncope

We investigated fluid shifts and regulatory responses to variations of posture, exercise, Gz level and radius of rotation in subjects riding NASA Ames 20G centrifuge. Results are from 4 protocols that address radius and exercise effects only. Protocol A: After 10 min supine control, 12 healthy men (35 9 yr, 82.8 7.9 kg) were exposed to rotational 1 Gz (2.5 m radius) for 2 min followed by 20 min alternating between 1 and 1.25 Gz. Blood samples were taken pre and post spin. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 8.3 m. Protocol D: Same as B but at 8.3 m. The 8 subjects who completed all protocols, increased heart rate (HR) from control by: A: 5, B: 39, C: 11, D: 44 bpm; and the 4 who did not: A: 6, B: 35, C: 20, D: 50 bpm. For thoracic fluid volume, (bioimpedance), the 8 subjects changed from control: A: -394, B: -548, C: -537, D: -708 mL; and the 4: A: -516, B: -652, C: -583, D: -1263 mL. The 4 subjects lost more thoracic fluid volume than the 8, especially in protocol D. A slightly greater increase in HR for the 4 compared to the 8 was not adequate to maintain cardiac output during D. Our data support the concept that thoracic impedance can detect inability to return adequate fluid to the heart, thereby predicting presyncope.

Howarth, M. S.↗

Application of redundancy in the Saturn 5 guidance and control system

The Saturn launch vehicle's guidance and control system is so complex that the reliability of a simplex system is not adequate to fulfill mission requirements. Thus, to achieve the desired reliability, redundancy encompassing a wide range of types and levels was employed. At one extreme, the lowest level, basic components (resistors, capacitors, relays, etc.) are employed in series, parallel, or quadruplex arrangements to insure continued system operation in the presence of possible failure conditions. At the other extreme, the highest level, complete subsystem duplication is provided so that a backup subsystem can be employed in case the primary system malfunctions. In between these two extremes, many other redundancy schemes and techniques are employed at various levels. Basic redundancy concepts are covered to gain insight into the advantages obtained with various techniques. Points and methods of application of these techniques are included. The theoretical gain in reliability resulting from redundancy is assessed and compared to a simplex system. Problems and limitations encountered in the practical application of redundancy are discussed as well as techniques verifying proper operation of the redundant channels. As background for the redundancy application discussion, a basic description of the guidance and control system is included.

Moore, F. B.↗

Free-flying teleoperator for space missions

The design of a free-flying teleoperator (FFTO) intended to assist the Space Shuttle in performing its various missions is discussed, where FFTO is to be carried into earth orbit and returned to earth by the Shuttle. The FFTO system is described as to configuration, major subsystems, and mechanization concept. The kinematics of the manipulator and methods of sedating a satellite are discussed. Satellite equations of motion are provided, and cases of zero tumbling rate and non-zero tumbling rate are examined. Cases for which use of FFTO is compulsory are indicated, and the FFTO contributions to the Shuttle missions are analyzed.

Hung, J. C.↗