Engineering Papers⌕ Search

Engineering topics

Moore, Angela S.

Publications and source records attributed to Moore, Angela S..

Radiological Data Assessment Guidance for Emergency Response

This document provides guidance on how to apply data quality practices to measurements and information collected during the response and recovery to a radiological release. The process of applying data quality practices to measurement data is called data assessment. All data quality practices applied during a radiological incident response must balance the rigorous and time-consuming process normally applied to, for example, site decommissioning and decontamination, with the time- and resource-constraints present during emergency response. The guidance in this document presents the application of data quality practices for data assessment in a graded approach, where the recommended rigor increases as the response continues through its phases and as time and resource constraints relax.

54 ENVIRONMENTAL SCIENCES↗

Recommendations for Radiological Data Assessment Implementation

Since thorough verification, validation, and data quality assessment (DQA) processes may delay incident commanders and elected and appointed officials from making key decisions, the U.S. Department of Homeland Security (DHS) National Urban Security Technology Laboratory (NUSTL) tasked Pacific Northwest National Laboratory (PNNL) to develop tools and guidance for the federal, state, local, tribal, and territorial (FSLTT) responders using research, discussions with select FSLTT responders, and the experiences of subject matter experts in incident response. This report provides NUSTL with recommendations on best practices for verification, validation, and data quality assessment for the data collected by responders during a radiological or nuclear event. The purpose of this report is to inform the development of a DQA toolkit aimed at the needs of data assessors during the response to a radiological incident.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a Neutron List Mode Collar (LMCL) and a List Mode Response Matrix Analysis Concept

This report was prepared for the Safeguards Program of the US Department of Energy’s (DOE’s) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The report presents the development of the neutron nondestructive assay system, the List Mode Collar (LMCL) for the project OR16-List Mode for Collar-PD1La “List Mode Response Matrix for Advanced Correlated Neutron Analysis for Nuclear Safeguards.” The new list mode electronics developed under this project, and a spatial analysis concept called the List Mode Response Matrix are also described in this report. Analysis algorithms based on classification methods are published in a separate report. This research addresses the need to expand the capabilities of current nondestructive assay systems used for nuclear safeguards applications and considers the sustainability of safeguards technologies by the development of a “retrofit” concept using electronics based on modern standards. Furthermore, employing list mode data acquisition enabled the development of a spatial analysis concept and empirical measurement of a spatial response not previously used for safeguards neutron counting applications or measured in a traditional neutron collar detector and, therefore, provides new capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗