Combined speckle- and propagation-based single shot two-dimensional phase retrieval method

Single-shot two-dimensional (2D) phase retrieval (PR) can recover the phase shift distribution within an object from a single 2D x-ray phase contrast image (XPCI). Two competing XPCI imaging modalities often used for single-shot 2D PR to recover material properties critical for predictive performance capabilities are: speckle-based (SP-XPCI) and propagation-based (PB-XPCI) XPCI imaging. However, PR from SP-XPCI and PB-XPCI images are, respectively, limited to reconstructing accurately slowly and rapidly varying features due to noise and differences in their contrast mechanisms. Herein, we consider a combined speckle- and propagation-based XPCI (SPB-XPCI) image by introducing a mask to generate a reference pattern and imaging in the near-to-holographic regime to induce intensity modulations in the image. We develop a single-shot 2D PR method for SPB-XPCI images of pure phase objects without imposing restrictions such as object support constraints. It is compared against PR methods inspired by those developed for SP-XPCI and PB-XPCI on simulated and experimental images of a thin glass shell before and during shockwave compression. Reconstructed phase maps show improvements in quantitative scores of root-mean-square error and structural similarity index measure using our proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative x ray phase contrast imaging of oblique shock wave–interface interactions

Oblique shock wave–interface interactions of gases and liquids have been extensively studied in shock tubes using optical methods to measure equation-of-state (EOS) parameters. However, this is difficult with solids due to their opaqueness to visible light. X ray phase contrast imaging (XPCI) has the penetrative strength to probe solids while still being sensitive to mass density and enhancing the visibility of material boundaries. We investigate the accuracy and repeatability of measuring the mean value of the average mass density (areal density divided by thickness) over region S (B S ) and flow deflection angle (θ) from XPCI images of a sample. To that end, a Hough transform-based method for measuring θ is developed. To measure B S , the XPCI image intensity probability density function (PDF) is modeled accounting for the spatial distribution of x ray energy, scintillator response, and pulse-to-pulse variation in the x ray intensity. In addition, a Monte Carlo-based algorithm for computing the B S PDF is developed. Both methods are validated on an impact-generated oblique shock wave interacting at a solid polymer-to-polymer interface. Furthermore this is accomplished through a comparison to hydrodynamic simulations using well-established EOS. Under the modeling framework for the XPCI image intensity, B S is computed with an accuracy of < 0.1% and precision of 3%–5%, while θ has an uncertainty of 0.2°, respectively. This shows that the XPCI-based model that is developed here could be an invaluable tool for high-fidelity testing of hydrodynamic models in shock polar configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research

X-ray phase contrast imaging (XPCI) provides enhanced image contrast beyond absorption-based x-ray imaging alone due to refraction and diffraction from gradients in the object material density. It is sensitive to small variations in density, such as internal voids, cracks, grains, defects, and material flow, as well as to stronger density variations such as from a shock wave. Beyond its initial use in biology and materials science, XPCI is now routinely used in inertial confinement fusion (ICF) and high energy density (HED) research, first to characterize ICF capsules and targets, and later applied in dynamic experiments, where coherent x-ray sources, ultrafast x-ray pulses, and high temporal and spatial resolution are required. In this Review article, XPCI image formation theory is presented, its diverse use in ICF and HED research is discussed, the unique requirements for ultrafast XPCI imaging are given, as well as current challenges and issues in its use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo N-Particle forward modeling for density reconstruction of double shell capsule radiographs

In the Double Shell Inertial Confinement Fusion concept, characterizing the shape asymmetry of imploding metal shells is vital for understanding energy-efficient compression and radiative losses of the thermonuclear fuel. The Monte Carlo N-Particle MCNP® code forward models radiography of Double Shell capsule implosions using the Advanced Radiographic Capability at the National Ignition Facility. A procedure is developed for using MCNP to reconstruct density profiles from the radiograph image intensity. For a given Double Shell imploding target geometry, MCNP radiographs predict image contrast, which can help guide experimental design. Finally, in future work, the calculated MCNP synthetic radiographs will be compared with experimental radiographs to determine the radial and azimuthal density profiles of the Double Shell capsules.

47 OTHER INSTRUMENTATION↗

Novel fabrication tools for dynamic compression targets with engineered voids using photolithography methods

Mesoscale imperfections, such as pores and voids, can strongly modify the properties and the mechanical response of materials under extreme conditions. Tracking the material response and microstructure evolution during void collapse is crucial for understanding its performance. In particular, imperfections in the ablator materials, such as voids, can limit the efficiency of the fusion reaction and ultimately hinder ignition. To characterize how voids influence the response of materials during dynamic loading and seed hydrodynamic instabilities, we, in this paper, have developed a tailored fabrication procedure for designer targets with voids at specific locations. Our procedure uses SU-8 as a proxy for the ablator materials and hollow silica microspheres as a proxy for voids and pores. By using photolithography to design the targets’ geometry, we demonstrate precise and highly reproducible placement of a single void within the sample, which is key for a detailed understanding of its behavior under shock compression. This fabrication technique will benefit high-repetition rate experiments at x-ray and laser facilities. Insight from shock compression experiments will provide benchmarks for the next generation of microphysics modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗