Extension of Argonne’s Plant Dynamics Code (PDC) Capabilities to TerraPower Direct-Cycle Supercritical CO2 (“Pascal”) Nuclear Reactor Concept. Final CRADA report

Argonne National Laboratory (the Contractor) and TerraPower, LLC, (the Participant), entered into a Cooperative Research and Development Agreement (CRADA) to extend the Plant Dynamics Code (PDC) to model the Pascal reactor plant. PDC is the system-level computer code developed at Argonne, primarily for design and transient analysis of supercritical carbon dioxide (sCO2) energy conversion systems for various power plants. Pascal is a supercritical carbon dioxide (sCO2)-cooled direct-cycle nuclear power reactor under development by TerraPower. New features were added to the code to model components and systems specific to the Pascal plant and to make the code readily available as a tool for design, control, and safety analysis for this and other direct-cycle power plants. TerraPower provided design information of the Pascal reactor and the requirements for the development of the new PDC features. Argonne modified the PDC capabilities to introduce the new features.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with the FFTF LOFWOS Tests #10-12

The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. The results of modeling and simulation of LOFWOS Tests #10, #11, and #12 are presented in this report to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. These three tests did not use the primary loop pony motors and thus transitioned to natural circulation flow rates from varying initial power levels. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project (CRP) for benchmark analysis of the FFTF LOFWOS Test #13. The SAS4A/SASSYS-1 model originally developed for the CRP has been extended to include LOFWOS Tests #10-12 and modernized to utilize new code features and modeling practices. Predicted results from SAS4A/SASSYS-1 were compared to measured test data and differences were investigated. Overall, it was concluded that, for LOFWOS Tests #10-12, there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Status Report FY20 Q2

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (like a redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed, most primary component have been fabricated, primary components are being assembled in preparation for initial testing, and procurement is continuing with the secondary system components. Since the FY19 THETA status report, The THETA primary system components are at Argonne National Laboratory (ANL) and have been dry assembled. The secondary sodium system for heat rejection from intermediate heat exchanger has all been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger has been procured.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Status Report for FY2019 (Rev. 1)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NEUP Final Report: Analysis of Thermal Transients for a Sodium-CO 2 Heat Exchanger

The design of heat exchangers for use in a supercritical carbon dioxide (sCO 2 ) Brayton cycle power converter must provide for acceptable performance for duty cycle events encompassing anticipated transients and postulated accidents. Argonne National Laboratory participated in the NEUP project, “Thermal Hydraulic and Structural Testing and Modeling of Compact Diffusion-Bonded Heat Exchangers for Supercritical CO 2 Brayton Cycle” with the task of conducting a comprehensive analysis of thermal transients for sCO 2 cycle heat exchangers, with emphasis on the sodium-to-CO 2 heat addition heat exchanger. A range of transients, from normal operation to severe accidents, were simulated with the coupled PDC and SAS4A/SASSYS-1 system level dynamic analysis computer codes. For each transient, the calculated change in the heat exchanger wall temperature is determined as a measure of the thermal loading. In addition, an analysis to find an equivalent helium-CO 2 heat exchanger was carried out to facilitate testing with helium rather than sodium on the hot side.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PDC: Plant Dynamics Code for Design and Transient Analysis of Supercritical Brayton Cycles

The current report documents the Plant Dynamics Code developed at the Argonne National Laboratory for steady-state and transient analysis of supercritical Brayton cycles. The report consists of three major parts. Code Overview provides the general description of the code, including the purpose of the code development and the code’s main features. User’s Guide explains how to work with the code, including its user interface. Code Manual provides the detailed description of the code, including modeling, assumptions, and the solution schemes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of IST Turbomachinery Power-Neutral Tests with the ANL Plant Dynamics Code

The validation of the Plant Dynamics Code (PDC) developed at Argonne National Laboratory (ANL) for the steady-state and transient analysis of supercritical carbon dioxide (sCO2) systems has been continued with new test data from the Naval Nuclear Laboratory (operated by Bechtel Marine Propulsion Corporation) Integrated System Test (IST). Although data from three runs were provided to ANL, only two of the data sets were analyzed and described in this report. The common feature of these tests is the power-neutral operation of the turbine-compressor shaft, where no external power through the alternator was provided during the tests. Instead, the shaft speed was allowed to change dictated by the power balance between the turbine, the compressor, and the power losses in the shaft. The new test data turned out to be important for code validation for several reasons. First, the power-neutral operation of the shaft allows validation of the shaft dynamics equations in asynchronous mode, when the shaft is disconnected from the grid. Second, the shaft speed control with the compressor recirculation (CR) valve not only allows for testing the code control logic itself, but it also serves as a good test for validation of both the compressor surge control and the turbine bypass control actions, since the effect of the CR action on the loop conditions is similar for both of these controls. Third, the varying compressor-inlet temperature change test allows validation of the transient response of the precooler, a shell-and-tube heat exchanger. The first transient simulation of the compressor-inlet temperature variation Test 64661 showed a much slower calculated response of the precooler in the calculations than the test data. Further investigation revealed an error in calculating the heat exchanger tube mass for the PDC dynamic equations that resulted in a slower change in the tube wall temperature than measured. The transient calculations for both tests were done in two steps. The first step was done in the same fashion as the FY15 IST analysis, where the CR valve position and the turbine-compressor shaft speed were specified through the PDC input based on the test values. On the second step, the turbine-compressor shaft dynamics equations were invoked by specifying that the shaft is disconnected from the grid. In addition, the CR valve control was used to control the shaft speed, based on the turbine bypass control logic already implemented in the PDC. For the shaft power balance, the friction (windage) loss is calculated based on the shaft balance at the steady-state conditions and is assumed to be scaled to the third power of shaft speed in the transient. Both the steady-state and transient simulations of both tests showed good agreement with the test data. The only significant difference was the turbine performance, which was not predicted as well as it was in the previous IST simulation, resulting in the prediction of a somewhat different flow split between the two turbines. This flow split difference is believed to be the result of not addressing the recent turbine modifications in the model. In addition, the full simulation of the turbine-compressor speed variation Test 65261-P with shaft speed control showed greater a difference with the test data later in the transient than the other test. Further analysis of the results revealed that this difference is most likely due to scaling the shaft windage losses only with the shaft speed and ignoring its dependency on the fluid density in the shaft cavity. Based on the results of steady state and transient calculations of the Tests 64661 and 65216-P, several areas of future improvements for the PDC simulation of the IST are identified.

42 ENGINEERING↗

Dry Air Cooler Modeling for Supercritical Carbon Dioxide Brayton Cycle Analysis

Modeling for commercially available and cost effective dry air coolers such as those manufactured by Harsco Industries has been implemented in the Argonne National Laboratory Plant Dynamics Code for system level dynamic analysis of supercritical carbon dioxide (sCO 2 ) Brayton cycles. The modeling can now be utilized to optimize and simulate sCO 2 Brayton cycles with dry air cooling whereby heat is rejected directly to the atmospheric heat sink without the need for cooling towers that require makeup water for evaporative losses. It has sometimes been stated that a benefit of the sCO 2 Brayton cycle is that it enables dry air cooling implying that the Rankine steam cycle does not. A preliminary and simple examination of a Rankine superheated steam cycle and an air-cooled condenser indicates that dry air cooling can be utilized with both cycles provided that the cycle conditions are selected appropriately

42 ENGINEERING↗

FASTER Test Reactor Preconceptual Design Report

The FASTER test reactor plant is a sodium-cooled fast spectrum test reactor that provides high levels of fast and thermal neutron flux for scientific research and development. The 120MWe FASTER reactor plant has a superheated steam power conversion system which provides electrical power to a local grid allowing for recovery of operating costs for the reactor plant.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FASTER test reactor preconceptual design report summary

The FASTER reactor plant is a sodium-cooled fast spectrum test reactor that provides high levels of fast and thermal neutron flux for scientific research and development. The 120MWe FASTER reactor plant has a superheated steam power conversion system which provides electrical power to a local grid allowing for recovery of operating costs for the reactor plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress report on dynamic simulation of the Sandia small-scale supercritical carbon dioxide brayton cycle test loop with the ANL plant dynamics code

Validation of the Plant Dynamics Code (PDC) with available experiment data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration has been continued. Previously, one of the earlier loop configurations from December 2010 was modeled with the steady-state portion of the PDC. In order to be able to simulate transient behavior of the loop with the PDC, several modifications specific to the SNL Loop needed to be implemented in the code.

Moisseytsev, A.↗

AFR-100 safety analyses

The Advanced Fast Reactor-100 (AFR-100) is Argonne National Laboratory's 250 MWth metal-fueled modular sodium-cooled pool-type fast reactor concept. [1] A series of accident sequences that focused on the AFR-100's ability to provide protection against reactor damage during low probability accident sequences resulting from multiple equipment failures were examined. Protected and Unprotected Loss of Flow (PLOF and ULOF) and Unprotected Transient Over-Power (UTOP) accidents were simulated using the SAS4A/SASSYS-1 safety analysis code. The large heat capacity of the sodium in the pool-type reactor allows the AFR-100 to absorb large amounts of energy during a PLOF with relatively small temperature increases throughout the system. During a ULOF with a 25-second flow halving time, coolant and cladding temperatures peak around 720 deg. C within the first minute before reactivity feedback effects decrease power to match the flow. Core radial expansion and fuel Doppler provide the necessary feedback during the UTOP to bring the system back to critical before system temperatures exceed allowable limits. Simulation results indicate that adequate ULOF safety margins exist for the AFR-100 design with flow halving times of twenty-five seconds. Significant safety margins are maintained for PLOF accidents as well as UTOP accidents if a rod stop is used. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AFR-100 Safety Analyses

Preliminary analyses have been completed to assess the potential safety performance characteristics of the Advanced Fast Reactor (AFR) 250 MWth design. The scope of the analyses presented here focuses on the ability of AFR to provide inherent protection against damaging consequences in low probability accident sequences involving multiple equipment failures.