Engineering Papers⌕ Search

Engineering topics

Mizuno, T

Publications and source records attributed to Mizuno, T.

SU-F-T-255: Accuracy and Precision of Dynamic Tracking Irradiation with VERO-4DRT System

Purpose: The VERO-4DRT system is able to provide dynamic tracking irradiation (DTI) for the target with respiratory motion. This technique requires enough commissioning for clinical implementation. The purpose of this study is to make sure the accuracy and precision of DTI using VERO- 4DRT through commissioning from fundamental evaluation to end-to-end test. Method: We evaluated several contents for DTI commissioning: the accuracy of absorption dose at isocenter in DTI, the field size and penumbra of DTI, the accuracy of 4D modeling in DTI. All evaluations were performed by respiratory motion phantom (Quasar phantom). These contents were compared the results between static irradiation and DTI. The shape of radiation field was set to square from 3 cm × 3 cm to 10 cm × 10 cm. The micro 3D chamber and Gafchromic EBT3 film were used for absorbed dose and relative dose distribution measurement, respectively. The sine and irregular shaped waves were used for demonstrative respiratory motion. The visicoil was implanted into the phantom for guidance of respiratory motion. The respiration patterns of frequency and motion amount were set to 10–15 BPM and 1–2 cm, respectively. Results: As the result of absorbed dose of DTI in comparison with static irradiation, the average dose error at isocenter was 0.5% even though various respiratory patterns were set on. As the result of relative dose distribution, the field size (set it on 50% dose line) was not significantly changed in all respiratory patterns. However, the penumbra was larger in greater respiratory motion (up to 4.1 mm). The 4D modeling coincidence between actual and created waves was within 1%. Conclusion: The DTI using VERO-4DRT can provide sufficient accuracy and precision in absorbed dose and distribution. However, the patientspecific quantitative internal margin corresponding respiratory motion should be taken into consideration with image guidance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-433: Field-In-Field Irradiation for Breast Cancer with VERO-4DRT System: A Feasibility Study

Purpose: The Vero-4DRT system is a dedicated system for high precision radiation therapy. However, the field size is limited at 15 cm x 15 cm and shapes by using multi-leaf collimator (MLC) without X-Jaw and Y-Jaw. Therefore VERO-4DRT system is not available to simple wedged irradiation for breast cancer. In this study, we suppose FIF with ring and/or tilt/pan angles whole breast irradiation (FIFWBI). The purpose of this study is to verify the feasibility of FIFWBI with VERO-4DRT system. Methods: As fundamental evaluation, we performed commissioning test with phantom. The absorbed dose evaluation at several reference points and dose distribution including split area were performed. We planned 10 demonstrative shapes in phantom for measuring these contents with i-plan workstation (BrainLAB). As clinical evaluation, the dose distribution and dose indexes were evaluated with actual patient data. Five patients with breast cancer were designed FIFWBI radiotherapy plan with split fields. Then, the dose distribution and dose indexes (including Dmax, Dmin, D95, D5 and Homogeneity index) were evaluated in these plans. Results: As the results of fundamental evaluation, all absorbed dose errors between calculated and measured doses were within 2%. The gamma passing rates with 2 mm/3% criteria in all cases were 96±2%. As the results of clinical evaluation, the values of Dmax, D95, D50, D5, and Homogeneity Index were 41.7±0.90 Gy, 49.4±0.34 Gy, 52.26±0.24 Gy, and 1.39±0.03, respectively. For Japanese breast cancer patients, this technique was feasible. However, the large split region was happened in FIFWBI in case of patient with large breast. Conclusion: We evaluated the FIFWBI technique with VERO-4DRT system. This technique is feasible for Japanese patients, but the patient with large breast should be disagreed with this technique.

60 APPLIED LIFE SCIENCES↗

GRB 091208B: FIRST DETECTION OF THE OPTICAL POLARIZATION IN EARLY FORWARD SHOCK EMISSION OF A GAMMA-RAY BURST AFTERGLOW

We report that the optical polarization in the afterglow of GRB 091208B is measured at t = 149-706 s after the burst trigger, and the polarization degree is P = 10.4( {+-} 2.5%. The optical light curve at this time shows a power-law decay with index -0.75 {+-} 0.02, which is interpreted as the forward shock synchrotron emission, and thus this is the first detection of the early-time optical polarization in the forward shock (rather than that in the reverse shock reported by Steele et al.). This detection disfavors the afterglow model in which the magnetic fields in the emission region are random on the plasma skin depth scales, such as those amplified by the plasma instabilities, e.g., Weibel instability. We suggest that the fields are amplified by the magnetohydrodynamic instabilities, which would be tested by future observations of the temporal changes of the polarization degrees and angles for other bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

C{sub 60} fragmentation in charge-changing collisions with slow Au{sup +} ions

We investigated ionization and fragmentation of C{sub 60} in the charge-changing collisions of 2.0 keV/amu Au{sup +} ions with C{sub 60} molecules. We performed simultaneous measurements of product ions, the number of secondary electrons, and a charge-selected outgoing Au projectile. The production of C{sub 60}{sup +} ions was predominant in the single-electron capture (1-capture) process. In contrast, multifragmentation of C{sub 60} was predominant in the single-electron loss (1-loss) process. The multifragmentation was enhanced in the 1-loss process compared with the 1-capture process when the same number of electrons was emitted from C{sub 60}. This enhancement was also observed when a fast Si ion traveled close to a carbon nucleus [T. Majima et al., Phys. Rev. A 74, 033201 (2006)]. The 1-loss process of slow Au{sup +} ions is considered to occur closer to a carbon nucleus than does the 1-capture process. Multifragmentation of C{sub 60} is caused by internal electronic excitation although it is probably assisted by nuclear stopping when, at least, the electronic excitation of C{sub 60} is small.

74 ATOMIC AND MOLECULAR PHYSICS↗

Kinetic-energy release in N{sub 2} fragmentation by charge-changing collisions of 2-MeV C{sup +} ions

Collision-induced fragmentation of N{sub 2} was investigated for 2-MeV C{sup +} ions under charge-changing conditions of C{sup +{yields}}C{sup q+} (q=0,2,3). Coincidence measurement of fragment ions was performed by means of a momentum three-dimensional imaging technique at scattering angles of {theta}=0 and 1.0 mrad. Kinetic-energy release (KER) obtained for a fragmentation channel of N{sub 2}{sup 2+{yields}}N{sup +}+N{sup +} was found to differ significantly in electron loss and capture collisions. In two-electron-loss collisions (C{sup +{yields}}C{sup 3+}), KER spectra were essentially identical for {theta}=0 and 1.0 mrad. It is concluded that the energy level of dissociating excited states of N{sub 2}{sup 2+} may be saturated when the interaction strength, defined as (q/vb), exceeds 0.65, where q and v are the charge and the velocity, respectively, of an incident ion, and b is the impact parameter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-resolved photoelectron imaging using a femtosecond UV laser and a VUV free-electron laser

A time-resolved photoelectron imaging using a femtosecond ultraviolet (UV) laser and a vacuum UV free-electron laser is presented. Ultrafast internal conversion and intersystem crossing in pyrazine in a supersonic molecular beam were clearly observed in the time profiles of photoioinzation intensity and time-dependent photoelectron images.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of secondary particle behavior in multiaperture, multigrid accelerator for the ITER neutral beam injector

Heat load on acceleration grids by secondary particles such as electrons, neutrals, and positive ions, is a key issue for long pulse acceleration of negative ion beams. Complicated behaviors of the secondary particles in multiaperture, multigrid (MAMuG) accelerator have been analyzed using electrostatic accelerator Monte Carlo code. The analytical result is compared to experimental one obtained in a long pulse operation of a MeV accelerator, of which second acceleration grid (A2G) was removed for simplification of structure. The analytical results show that relatively high heat load on the third acceleration grid (A3G) since stripped electrons were deposited mainly on A3G. This heat load on the A3G can be suppressed by installing the A2G. Thus, capability of MAMuG accelerator is demonstrated for suppression of heat load due to secondary particles by the intermediate grids.

43 PARTICLE ACCELERATORS↗

Analyses of high power negative ion accelerators for ITER neutral beam injector (invited)

In JAEA, research and developments to realize high power accelerator (1 MeV, 40 AD{sup -} ion beams for 3600 s) for ITER have been carried out experimentally and numerically utilizing a five stage MAMuG (Multiaperture, Multigrid) accelerator. In this paper, the extension of the gap length, which is required to improve the voltage holding capability, is examined in two dimensional beam optics analyses and also from view point of stripping loss of ions. In order to suppress excess power loadings due to the direct interception of negative ions, which is issued in long pulse tests, the beamlet deflection is analyzed in three dimensional multibeamlet analyses. The necessary modifications shown above are applied to the MAMuG accelerator for coming long pulse tests in JAEA and ITER.

43 PARTICLE ACCELERATORS↗

3D modeling of the electron energy distribution function in negative hydrogen ion sources

For optimization and accurate prediction of the amount of H-ion production in negative ion sources, analysis of electron energy distribution function (EEDF) is necessary. We are developing a numerical code which analyzes EEDF in the tandem-type arc-discharge source. It is a three-dimensional Monte Carlo simulation code with realistic geometry and magnetic configuration. Coulomb collision between electrons is treated with the ''binary collision'' model and collisions with hydrogen species are treated with the ''null-collision'' method. We applied this code to the analysis of the JAEA 10 A negative ion source. The numerical result shows that the obtained EEDF is in good agreement with experimental results.

43 PARTICLE ACCELERATORS↗

Long pulse H{sup -} ion beam acceleration in MeV accelerator

A multiaperture multigrid accelerator called ''MeV accelerator'' has been developed for neutral beam injection system of international thermonuclear experimental reactor. In the present work, long pulse H{sup -} ion beam acceleration was performed by the MeV accelerator equipped with new water-cooled grids. At present, the pulse length was extended to 5 s for the beams of 750 keV, 221 mA, and 10 s for the beams of 600 keV, 158 mA. Energy density, defined as products of beam energy (keV), current (mA), and pulse (s) divided by aperture area (m{sup 2}), increased more than one order of magnitude higher compared with original MeV accelerator without water cooling in its grids. At higher energy and current, the grid was melted by beam deflection. Due to this grid melting, breakdowns occurred between the grids, and hence, the pulse length was limited. Beam deflection will be compensated by aperture displacement in next experiment.

43 PARTICLE ACCELERATORS↗

Measurement of kinetic energy release in CO fragmentation by charge-changing collisions of fast heavy ions

We study ionization and fragmentation of CO in electron loss and capture collisions of B{sup 2+}, O{sup 2+}, and Si{sup 2+} ions at an energy of 71.4 keV/u (v=1.69 a.u.). Coincidence measurements of fragment ions from CO and charge-selected ions were performed by means of a momentum three-dimensional imaging technique. Production cross sections of CO{sup r+} and branching ratios into various fragmentation channels were obtained for r=1-4. We also measured kinetic energy release (KER) in individual fragmentation channels. The KER spectra for r<=2 are found to be different for electron loss and capture collisions, while the difference becomes small for r>=3. As a measure of the degree of molecular fragmentation, the magnitude of the binding energy of the relevant electronic states seems the important parameter both in loss and capture collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

The GLAST Background Model

In order to estimate the ability of the GLAST/LAT to reject unwanted background of charged particles, optimize the on-board processing, size the required telemetry and optimize the GLAST orbit, we developed a detailed model of the background particles that would affect the LAT. In addition to the well-known components of the cosmic radiation, we included splash and reentrant components of protons, electrons (e+ and e-) from 10 MeV and beyond as well as the albedo gamma rays produced by cosmic ray interactions with the atmosphere. We made estimates of the irreducible background components produced by positrons and hadrons interacting in the multilayered micrometeorite shield and spacecraft surrounding the LAT and note that because the orbital debris has increased, the shielding required and hence the background are larger than were present in EGRET. Improvements to the model are currently being made to include the east-west effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗