An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

High quality superconducting Nb co-planar resonators on sapphire substrate

We present measurements and simulations of superconducting Nb co-planar waveguide resonators on sapphire substrate down to millikelvin temperature range with different readout powers. In the high temperature regime, we demonstrate that the Nb film residual surface resistance is comparable to that observed in the ultra-high quality, bulk Nb 3D superconducting radio frequency cavities while the resonator quality is dominated by the BCS thermally excited quasiparticles. At low temperature both the resonator quality factor and frequency can be well explained using the two-level system models. Through the energy participation ratio simulations, we find that the two-level system loss tangent is $\sim 10^{-2}$, which agrees quite well with similar studies performed on the Nb 3D cavities.

Zhu, S.↗

Ultrafast Self-Induced X-Ray Transparency and Loss of Magnetic Diffraction

Using ultrafast ≃2.5 fs and ≃25 fs self-amplified spontaneous emission pulses of increasing intensity and a novel experimental scheme, we report the concurrent increase of stimulated emission in the forward direction and loss of out-of-beam diffraction contrast for a Co/Pd multilayer sample. The experimental results are quantitatively accounted for by a statistical description of the pulses in conjunction with the optical Bloch equations. Here, the dependence of the stimulated sample response on the incident intensity, coherence time, and energy jitter of the employed pulses reveals the importance of increased control of x-ray free electron laser radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural, magnetic, dielectric and magneto-dielectric properties of (BaTiO3)0.70(Li0.3Zn0.4Fe2.3O4)0.30

Highlights: Microcrystals of BaTiO{sub 3} is incorporated in Li{sub 0.3}Zn{sub 0.4}Fe{sub 2.3}O{sub 4} using sol-gel method. Crystallographic phase and morphology of the composite is investigated. Magnetic ordering originates from the ferrimagnetic matrix of the composite. The dielectric behaviour is originated from the BaTiO{sub 3} particles in the composite. The composite shows strong magneto-electric property, useful for application. - Abstract: Structural, magnetic, dielectric and magneto-dielectric properties of (BaTiO{sub 3}){sub 0.70}(Li{sub 0.3}Zn{sub 0.4}Fe{sub 2.3}O{sub 4}){sub 0.30} [BTO-LZFO] composite are studied. To prepare the composite, microcrystals of BaTiO{sub 3} [BTO] prepared in solid-state reaction are taken along with the precursors of Li{sub 0.3}Zn{sub 0.4}Fe{sub 2.3}O{sub 4} [LZFO], prepared in sol-gel route. X-ray diffraction (XRD) study confirms the phase purity of the composite sample. High-resolution transmission electron microscopy also confirms the formation of the composite state. Analysis of magnetic data confirms the ferrimagnetic nature of the sample along with a fraction of superparamagnetic particles. The ferrimagnetism is explained by Néels’ two-sublattice model. The dielectric spectrum of the sample follows the Cole-Cole relaxation. Interestingly, the ferroelectric and dielectric behaviours of BTO are retained in the composite state of BTO-LZFO, though the magnetization is enhanced drastically. This enhanced magnetic property along with the ferroelectricity and strong magneto-dielectric coupling in the composite state confirms that BTO-LZFO can be used as a multiferroic material in different electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of cation distribution on the magnetic and hyperfine behaviour of nanocrystalline Co doped Ni–Zn ferrite (Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4})

Highlights: • Cation distribution in tetrahedral and octahedral sites of spinel Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4}. • Structural analysis of observed X-ray diffraction pattern using Rietveld method. • Study of hyperfine behaviour using Mössbauer spectroscopy. • Static and dynamic magnetic measurements. • Correlation of cation distributions obtained from Rietveld analysis with the results of magnetic and Mössbauer effect measurements. - Abstract: Nanoparticles of Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4} are prepared by a simple co-precipitation method. The as dried sample is heat treated at 400, 500, 600, 700 and 800 °C to obtain different sizes of nanoparticles. The crystallographic phase of the samples is confirmed analyzing observed X-ray diffraction (XRD) by Rietveld method. Hyperfine parameters of the samples are derived from room temperature (RT) Mössbauer spectra of the samples. Magnetic properties of the samples are investigated by static and dynamic hysteresis loops. Different magneto-crystalline parameters are calculated from the variation of magnetization with temperature (M–T curve) under zero field cooled (ZFC) and field cooled (FC) conditions of the as dried sample. The cation distribution estimated from Rietveld analysis are correlated with the results of magnetic and Mössbauer effect measurements. The observed high value of saturation magnetization (72.7 emu/g at RT) of the sample annealed at 800 °C would be interesting for applications in different electromagnetic devices.

36 MATERIALS SCIENCE↗

Linac Coherent Light Source data analysis using psana

Psana ( Photon Science Analysis ) is a software package that is used to analyze data produced by the Linac Coherent Light Source X-ray free-electron laser at the SLAC National Accelerator Laboratory. The project began in 2011, is written primarily in C++ with some Python, and provides user interfaces in both C++ and Python. Most users use the Python interface. The same code can be run in real time while data are being taken as well as offline, executing on many nodes/cores using MPI for parallelization. It is publicly available and installable on the RHEL5/6/7 operating systems.

Damiani, D.↗

Investigation of variation of energy of laser beam on structural, electrical and optical properties of pulsed laser deposited CuO thin films

In this paper, copper oxide (CuO) thin films have been deposited successfully by pulsed laser deposition technique using copper metal as target material. Thin films have been prepared under different energy of laser pulses ranging from 100mJ/pulse to 250 mJ/pulse. These films have been characterized for their structural, electrical and optical properties by using X-Ray Diffractometer (XRD), Four probe method and UV spectroscopy. Morphological and structural studies show that there is increase in crystallite size with the increase in energy of laser beam. Thus resulting in improved crystallinity and degree of orientation of the CuO thin films. Optoelectrical properties show direct relation between conductivity and energy of laser beam. Optical analysis of CuO thin films prepared under different energy of laser beam shows good agreement with structural analysis. The prepared CuO thin films show high absorbance in the UV and visible range and thus are suitable candidate for thin films solar cell application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CDF Run II silicon vertex detector annealing study

Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron collider delivered 12~fb$^{-1}$ of $p\bar{p}$ collisions at $\sqrt{s}=1.96$ TeV to the Collider Detector at Fermilab (CDF). During that time, the CDF silicon vertex detector was subject to radiation doses of up to 12 Mrad. After the end of operations, the silicon detector was annealed for 24 days at $18^{\circ}$C. In this paper, we present a measurement of the change in the bias currents for a subset of sensors during the annealing period. We also introduce a novel method for monitoring the depletion voltage throughout the annealing period. The observed bias current evolution can be characterized by a falling exponential term with time constant $\tau_I=17.88\pm0.36$(stat.)$\pm0.25$(syst.) days. We observe an average decrease of $(27\pm3)\%$ in the depletion voltage, whose evolution can similarly be described by an exponential time constant of $\tau_V=6.21\pm0.21$ days. These results are consistent with the Hamburg model within the measurement uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗