HCFC-225 Solvent Replacement Project: Cleaning and Verifying MSFC/SSC Propulsion Oxygen Systems
No abstract available
Engineering topics
Publications and source records attributed to Mitchell, Mark A..
No abstract available
Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon‐113 (CFC‐113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon‐225 (HCFC‐225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC‐225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both NASA and the Defense Logistics Agency ‐ Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC‐225 that is both an effective cleaner and safe for use with oxygen systems. This presentation summarizes the tests performed, results, and lessons learned. It also demonstrates the benefits of cross‐agency collaboration in a time of limited resources.
Gaseous and liquid oxygen are extremely reactive materials used in bipropellant propulsion systems. Both flight and ground oxygen systems require a high level of cleanliness to support engine performance, testing, and prevent mishaps. Solvents used to clean and verify the cleanliness of oxygen systems and supporting test hardware must be compatible with the system's materials of construction and effective at removing or reducing expected contaminants to an acceptable level. This paper will define the philosophy and test approach used for evaluating replacement solvents for the current Marshall Space Flight Center/Stennis Space Center baseline HCFC‐225 material that will no longer be available for purchase after 2014. MSFC/SSC applications in cleaning / sampling oxygen propulsion components, support equipment, and test system were reviewed then candidate replacement cleaners and test methods selected. All of these factors as well as testing results will be discussed.
To obtain a high degree of cleanliness without risk of corrosion or hazardous reactivity, hydrochlorofluorocarbon (HCFC)-225 is used for cleaning and cleanliness verification of oxygen system components used on NASA fs bipropellant launch vehicles, associated test stands and support equipment. HCFC-225 is a Class II Ozone Depleting Substance (ODS ]II) that was introduced to replace chlorofluorocarbon (CFC)-113, a Class I ODS solvent that is now banned. To meet environmental regulations to eliminate the use of ozone depleting substances, a replacement solvent is required for HCFC ]225 that is effective at removing oils, greases, and particulate from large oxygen system components, is compatible with materials used in the construction of these systems, and is nonflammable and non ]reactive in enriched oxygen environments. A solvent replacement is also required for aviator fs breathing oxygen systems and other related equipment currently cleaned and verified with HCFC ]225 and stockpiled CFC -113. Requirements and challenges in the search for nonflammable replacement solvents are discussed.
The technical objective of this project was to develop a ceramic HEPA filter technology, by initially producing and testing coupon ceramics, small scale prototypes, and full scale prototype HEPA filters, and to address relevant manufacturing and commercialization technical issues. The deliverable of the project would be a ceramic HEPA filter technology meeting the specifications of existing, glass fiber, nuclear grade HEPA systems. The existing HEPA filters are made from glass fiber, which is fragile and easily damaged due to impact by chemicals, high pressures and temperatures (see photographs in Fig. 1). A ceramic HEPA filter technology would overcome these problems and would allow the filter to be cleaned and reused, thereby reducing secondary waste. Additionally, ceramic HEPA filters will eliminate the associated costs and risks of contamination posed by "hot breaks" - the breaching of containment - required to periodically replace HEPA filters of current design. The ceramic HEPA filter technology would be designed to minimize retrofit problems and costs while meeting several key HEPA filter requirements.
Based on this limited laboratory study, solvent blends of trans-1,2 dichloroethylene with HFEs, HFCs, or PFCs appear to be viable alternatives to n-propyl bromide for vapor degreasing. The lower boiling points of these blends may lead to greater solvent loss during use. Additional factors must be considered when selecting a solvent substitute, including stability over time, VOC, GWP, toxicity, and business considerations.