Engineering Papers⌕ Search

Engineering topics

Milligan, Michael

Publications and source records attributed to Milligan, Michael.

At least 109 records · Page 6

Variability of Load and Net Load in Case of Large Scale Distributed Wind Power

Large scale wind power production and its variability is one of the major inputs to wind integration studies. This paper analyses measured data from large scale wind power production. Comparisons of variability are made across several variables: time scale (10-60 minute ramp rates), number of wind farms, and simulated vs. modeled data. Ramp rates for Wind power production, Load (total system load) and Net load (load minus wind power production) demonstrate how wind power increases the net load variability. Wind power will also change the timing of daily ramps.

17 WIND ENERGY↗

Impact of High Wind Power Penetration on Hydroelectric Unit Operations

The Western Wind and Solar Integration Study (WWSIS) investigated the operational impacts of very high levels of variable generation penetration rates (up to 35% by energy) in the western United States. This work examines the impact of this large amount of wind penetration on hydroelectric unit operations. Changes in hydroelectric unit operating unit patterns are examined for an aggregation of all hydro generators. The cost impacts of maintaining hydro unit flexibility are assessed and compared for a number of different modes of system operation.

13 HYDRO ENERGY↗

Distribution of Wind Power Forecast Errors from Operational Systems

Wind power forecasting is one important tool in the integration of large amounts of renewable generation into the electricity system. Wind power forecasts from operational systems are not perfect, and thus, an understanding of the forecast error distributions can be important in system operations. In this work, we examine the errors from operational wind power forecasting systems, both for asingle wind plant and for an entire interconnection. The resulting error distributions are compared with the normal distribution and the distribution obtained from the persistence forecasting model at multiple timescales. A model distribution is fit to the operational system forecast errors and the potential impact on system operations highlighted through the generation of forecast confidenceintervals.

17 WIND ENERGY↗

Are Integration Costs and Tariffs Based on Cost-Causation?

Integration cost analysis has progressed significantly over the past ten years. There is also a much better understanding of the cost drivers among the system stakeholders. This paper examines how wind and solar integration studies have evolved, what analysis techniques work, what common mistakes are still made, and what and why calculating integration costs is such a difficult problem thatshould be undertaken carefully, if at all. The many complex interactions among components of the power system and assumptions regarding the base case have important influences on integration cost estimates, and raise questions about whether integration cost components can be correctly untangled. We discuss many of these concerns and implications, shedding some light on the difficulties involvedin measuring and interpreting integration cost estimates.

14 SOLAR ENERGY↗

Best Practices in Grid Integration of Variable Wind Power: Summary of Recent US Case Study Results and Mitigation Measures

In only 6 years, from 2000 to 2006, wind energy has become a significant resource on many electric utility systems, with nearly 74,000 MW of nameplate capacity installed worldwide at the end of 2006. Wind energy is now “utility scale” and can affect utility system planning and operations for both generation and transmission. The utility industry in general, and transmission system operators in particular, are beginning to take note. As a result, numerous utility wind integration studies are being conducted in the US under a variety of industry structures. This paper will summarize results from a number of case studies conducted recently in the US, and outline a number of mitigation measures based on insights from the recent studies.

17 WIND ENERGY↗

Advanced Unit Commitment Strategies for the US Eastern Interconnection

With increasing penetrations of wind power on the eastern interconnection of the United States, much research has been discussed on how the increased uncertainty may change how the system is operated. In particular, unit commitment programs which decide what units need to be started up in order to meet the changing demand at least cost may need to have modifications in order to reduce costs and improve reliability on a power system with increasing uncertain variables. This paper outlines a study undertaken for the U.S. Eastern Interconnection in which different advanced unit commitment strategies were simulated for three different years to evaluate the benefits that may occur from using these strategies as an operational tool.

17 WIND ENERGY↗

Providing Minute-to-Minute Regulation from Wind Plants

Our earlier work showed that it may be both technically and economically feasible for wind plants to supply minute-to-minute regulation under some circumstances. In this paper, we extend the previous analysis using time series data from existing wind plants, system loads, and regulation and energy markets. Both wind plant response performance requirements and power system needs are addressed. In present-day regulation markets, the regulation market price is typically based on the supplier's opportunity cost in the energy market. With a near-zero marginal production cost, wind would not be expected to be an attractive regulation supplier most of the time. Minimum load problems, typically on nights with high wind, and the need for conventional generators to incur additional costs when operating above minimum loads appear to make regulation from wind an economical option for some hours of the year. Unlike contingency reserves whose prices are generally low at night, the price for regulation typically remains high around the clock. In this paper, we examine wind and regulation markets in several regions to assess the viability of the concept.

17 WIND ENERGY↗

Capacity Value of Wind Power - Summary

Power systems are planned such that they have adequate generation capacity to meet the load, according to a defined reliability target. The increase in the penetration of wind generation in recent years has led to a number of challenges for the planning and operation of power systems. A key metric for generation system adequacy is the capacity value of generation. The capacity value of a generator is the contribution that a given generator makes to generation system aequacy. The variable and stochastic nature of wind sets it apart from conventional energy sources. As a result, the modeling of wind generation in the same manner as conventional generation for capacity value calculations is inappropriate. In this paper a preferred method for calculation of the capacity value of wind is described and a discussion of the pertinent issues surrounding it is given. Approximate methods for the calculation are also described with their limitations highlighted. The outcome of recent wind capacity value analyses in Europe and North America, along with some new analysis, are highlighted with a discussion of relevant issues also given.

17 WIND ENERGY↗

Benefit of Regional Energy Balancing Service on Wind Integration in the Western Interconnection of the United States

Interest in various wide-area balancing schemes to help integrate wind have generated significant interest. As we have shown in past work, large balancing areas not only help with wind integration, but can also increase the efficiency of operations in systems without wind. Recent work on the Western Wind and Solar Integration Study (WWSIS) has found that combining balancing over the WestConnect footprint will increase the efficiency of commitment and dispatch at wind penetrations ranging from 10-20% of annual electricity demand, and will be essential for high penetrations and small balancing areas. In addition the Northwest Wind Integration Action Plan recommended balancing area cooperation as a method to help integrate the large potential wind development. In this paper we investigate the potential impact of a proposed Energy Imbalance Service on the ability of the non-market portions of Western Electricity Coordinating Councils (WECC) United States footprint to integrate wind energy. We will utilize data adapted from the WWSIS for the Western Interconnection. The analysis uses time-synchronized wind and load data to evaluate the potential for ramp requirement reduction that could be achieved with combined operation. Chronological analysis and ramp duration analysis quantify the benefit in terms of not only the ramp sizes, but the frequency of the potentially avoided ramps that must be managed by the non-wind generation fleet. Multiple approaches that can be used to achieve these benefits will also be suggested in the paper. We also suggest other approaches that can help achieve much of the benefit of full consolidation without requiring the physical consolidation of balancing areas.

17 WIND ENERGY↗

Operating Reserves and Wind Power Integration: An International Comparison

The determination of additional operating reserves in power systems with high wind penetration is attracting a significant amount of attention and research. Wind integration analysis over the past several years has shown that the level of operating reserve that is induced by wind is not a constant function of the installed capacity. Observations and analysis of actual wind plant operating data has shown that wind does not change its output fast enough to be considered as a contingency event. However, the variability that wind adds to the system does require the activation or deactivation of additional operating reserves. This paper provides a high-level international comparison of methods and key results from both operating practice and integration analysis, based on the work in International Energy Agency IEA WIND Task 25 on Large-scale Wind Integration. The paper concludes with an assessment of the common themes and important differences, along with recent emerging trends.

17 WIND ENERGY↗

Wind energy and power system operations: a review of wind integration studies to date

Wind integration will not be accomplished successfully by doing ''more of the same.'' It will require significant changes in grid planning and operations, continued technical evolution in the design and operation of wind turbines, further adoption and implementation of wind forecasting in the control room, and incorporation of market and policy initiatives to encourage more flexible generation. (author)

17 WIND ENERGY↗

Large-Scale Wind Integration Studies in the United States: Preliminary Results

This paper discusses key results that had emerged at the time from two studies, the Western Wind and Solar Integration Study (covers the footprint of WestConnect, a group of transmission owners that covers most of Colorado, New Mexico, Arizona, Nevada, and Wyoming) and the Eastern Wind Integration and Transmission Study (covers a large part of the Eastern Interconnection). Results from both studies showed that high wind penetrations could be successfully integrated into the power system, but were dependant on sufficient transmission and significant changes in operations.

17 WIND ENERGY↗

Comment on"Air Emissions Due to Wind and Solar Power" and Supporting Information

Katzenstein and Apt investigate the important question of pollution emission reduction benefits from variable generation resources such as wind and solar. Their methodology, which couples an individual variable generator to a dedicated gas plant to produce a flat block of power is, however, inappropriate. For CO{sub 2}, the authors conclude that variable generators 'achieve {approx} 80% of the emission reductions expected if the power fluctuations caused no additional emissions.' They find even lower NO{sub x} emission reduction benefits with steam-injected gas turbines and a 2-4 times net increase in NO{sub x} emissions for systems with dry NO{sub x} control unless the ratio of energy from natural gas to variable plants is greater than 2:1. A more appropriate methodology, however, would find a significantly lower degradation of the emissions benefit than suggested by Katzenstein and Apt. As has been known for many years, models of large power system operations must take into account variable demand and the unit commitment and economic dispatch functions that are practiced every day by system operators. It is also well-known that every change in wind or solar power output does not need to be countered by an equal and opposite change in a dispatchable resource. The authors recognize that several of their assumptions to the contrary are incorrect and that their estimates therefore provide at best an upper bound to the emissions degradation caused by fluctuating output. Yet they still present the strong conclusion: 'Carbon dioxide emissions reductions are likely to be 75-80% of those presently assumed by policy makers. We have shown that the conventional method used to calculate emissions is inaccurate, particularly for NO{sub x} emissions.' The inherently problematic methodology used by the authors makes such strong conclusions suspect. Specifically, assuming that each variable plant requires a dedicated natural gas backup plant to create a flat block of power ignores the benefits of diversity. In real power systems, operators are required to balance only the net variations of all loads and all generators, not the output of individual loads or generators; doing otherwise would ensure an enormous amount of unnecessary investment and operating costs. As a result, detailed studies that aggregate the variability of all loads and generators to the system level find that the amount of operating reserves required to reliably integrate variable resources into the grid are on the order of 10% of the nameplate capacity of the variable generators, even when upto25%of gross demand is being met by variable generation. The authors implicit assumption that incremental operating reserves must be 100% of the nameplate capacity of the variable generation, and be available at all times to directly counter that variability, excludes the option of decommitting conventional units when the load net of variable generation is low. In real power systems, generation response to wind variation can typically be met by a combination of committed units, each operating at a relatively efficient point of their fuel curves. In the Supporting Information, we conceptually demonstrate that the CO{sub 2} and NO{sub x} efficiency penalty found by the authors can be significantly reduced by considering the unit commitment decision with just five plants. Real systems often have tens to hundreds of plants that can be committed and decommitted over various time frames. Ignoring the flexibility of the unit commitment decision therefore leads to unsupportable results. Anumber of analyses of the fuel savings and CO{sub 2} emission benefits of variable generation have considered realistic operating reserve requirements and unit commitment decisions in models that include the reduction in part load efficiency of conventional plants. The efficiency penalty due to the variability of wind in four studies considered by Gross et al. is negligible to 7%, for up to a 20% wind penetration level. In short, for moderate wind penetration levels, 'there is no evidence available to date to suggest that in aggregate efficiency reductions due to load following amount to more than a few percentage points'. As such, other studies using a more appropriate methodology have found a much smaller CO{sub 2} penalty from variability than found by Katzenstein and Apt. Less information is available on the NO{sub x} emission penalty. Results from recent state-of-the-art integration studies in the United States indicate at the very least clear NO{sub x} emission reduction benefits from variable generation. NO{sub x} reductions estimated in these studies are discussed in more detail in the Supporting Information. Denny and O'Malley similarly find NO{sub x} reduction benefits when forecasting is used in the unit commitment decision.

14 SOLAR ENERGY↗