Precision Constraints for Three-Flavor Neutrino Oscillations from the Full MINOS + and MINOS Dataset
Not Available
Engineering topics
Publications and source records attributed to Miller, W. H..
Not Available
Not Available
We report new constraints on flavor-changing nonstandard neutrino interactions from the MINOS long-baseline experiment using νe and ν¯e appearance candidate events from predominantly νμ and ν¯μ beams. We used a statistical selection algorithm to separate νe candidates from background events, enabling an analysis of the combined MINOS neutrino and antineutrino data. We observe no deviations from standard neutrino mixing, and thus place constraints on the nonstandard interaction matter effect, |ϵeτ|, and phase, (δCP+δeτ), using a 30-bin likelihood fit.
We report new constraints on the size of large extra dimensions from data collected by the MINOS experiment between 2005 and 2012. Our analysis employs a model in which sterile neutrinos arise as Kaluza-Klein states in large extra dimensions and thus modify the neutrino oscillation probabilities due to mixing between active and sterile neutrino states. Using Fermilab’s Neutrinos at the Main Injector beam exposure of 10.56×1020 protons on target, we combine muon neutrino charged current and neutral current data sets from the Near and Far Detectors and observe no evidence for deviations from standard three-flavor neutrino oscillations. The ratios of reconstructed energy spectra in the two detectors constrain the size of large extra dimensions to be smaller than 0.45 μm at 90% C.L. in the limit of a vanishing lightest active neutrino mass. Stronger limits are obtained for nonvanishing masses.
Forward single π0 production by coherent neutral-current interactions, νA→νAπ0, is investigated using a 2.8×1020 protons-on-target exposure of the MINOS Near Detector. For single-shower topologies, the event distribution in production angle exhibits a clear excess above the estimated background at very forward angles for visible energy in the range 1–8 GeV. Cross sections are obtained for the detector medium comprised of 80% iron and 20% carbon nuclei with ⟨A⟩=48, the highest-⟨A⟩ target used to date in the study of this coherent reaction. The total cross section for coherent neutral-current single π0 production initiated by the νμ flux of the NuMI low-energy beam with mean (mode) Eν of 4.9 GeV (3.0 GeV), is 77.6±5.0(stat)-16.8+15.0(syst)×10-40 cm2 pernucleus. The results are in good agreement with predictions of the Berger-Sehgal model.
We report results of a search for oscillations involving a light sterile neutrino over distances of 1.04 and 735 km in a νμ-dominated beam with a peak energy of 3 GeV. The data, from an exposure of 10.56×1020 protons on target, are analyzed using a phenomenological model with one sterile neutrino. We constrain the mixing parameters θ24 and Δm412 and set limits on parameters of the four-dimensional Pontecorvo-Maki-Nakagawa-Sakata matrix, |Uμ4|2 and |Uτ4|2, under the assumption that mixing between νe and νs is negligible (|Ue4|2=0). No evidence for νμ→νs transitions is found and we set a world-leading limit on θ24 for values of Δm412≲1 eV2.
The charge ratio, Rμ=Nμ+/Nμ-, for cosmogenic multiple-muon events observed at an underground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly continuously from August 2003 until April 2012, comprise two independent data sets imaged with opposite magnetic field polarities, the comparison of which allows the systematic uncertainties of the measurement to be minimized. The multiple-muon charge ratio is determined to be Rμ=1.104±0.006(stat)-0.010+0.009(syst). This measurement complements previous determinations of single-muon and multiple-muon charge ratios at underground sites and serves to constrain models of cosmic-ray interactions at TeV energies.
This paper describes the hardware and operations of the Neutrinos at the Main Injector (NuMI) beam at Fermilab. It elaborates on the design considerations for the beam as a whole and for individual elements. The most important design details of individual components are described. Beam monitoring systems and procedures, including the tuning and alignment of the beam and NuMI long-term performance, are also discussed.
We report a two-detector measurement of the propagation speed of neutrinos over a baseline of 734 km. The measurement was made with the NuMI beam at Fermilab between the near and far MINOS detectors. The fractional difference between the neutrino speed and the speed of light is determined to be (v/c-1)=(1.0±1.1)×10-6, consistent with relativistic neutrinos.
N/A
We report on a new analysis of neutrino oscillations in MINOS using the complete set of accelerator and atmospheric data. The analysis combines the $\nu_{\mu}$ disappearance and $\nu_{e}$ appearance data using the three-flavor formalism. We measure $|\Delta m^{2}_{32}|=[2.28-2.46]\times10^{-3}\mbox{\,eV}^{2}$ (68% C.L.) and $\sin^{2}\theta_{23}=0.35-0.65$ (90% C.L.) in the normal hierarchy, and $|\Delta m^{2}_{32}|=[2.32-2.53]\times10^{-3}\mbox{\,eV}^{2}$ (68% C.L.) and $\sin^{2}\theta_{23}=0.34-0.67$ (90% C.L.) in the inverted hierarchy. The data also constrain $\delta_{CP}$, the $\theta_{23}$ octant degeneracy and the mass hierarchy; we disfavor 36% (11%) of this three-parameter space at 68% (90%) C.L.
N/A
Not Available
Not Available
Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.
Because of the high data-rate requirements, a practical system capable of collecting seismic information in the field and relaying it, via satellite, to a central collection point is not yet available. A seismic signal processor has been developed and tested for use with the NOAA/GOES satellite data collection system. Performance tests on recorded, as well as real time, short period signals indicate that the event recognition technique used is nearly perfect in its rejection of environmental noise and other non-seismic signals and that, with the use of solid state buffer memories, data can be acquired in many swarm situations. The design of a complete field data collection platform is discussed based on the prototype evaluation.
A seismic signal processor was developed and tested for use with the NOAA-GOES satellite data collection system. Performance tests on recorded, as well as real time, short period signals indicate that the event recognition technique used is nearly perfect in its rejection of cultural signals and that data can be acquired in many swarm situations with the use of solid state buffer memories. Detailed circuit diagrams are provided. The design of a complete field data collection platform is discussed and the employment of data collection platforms in seismic network is reviewed.
Previous calculations for rates of excitation of ortho-H2CO by collisions with He have been extended to higher rotational levels and kinetic temperatures to 80 K. Rates for para-H2CO have also been computed. Pressure-broadening widths for several spectral lines have been obtained from these calculations and are found to agree with recent data within the experimental uncertainty of 10%. Excitation of formaldehyde by collisions with H2 molecules is also discussed.