Engineering Papers⌕ Search

Engineering topics

Miller, R.

Publications and source records attributed to Miller, R..

At least 19 records

Interrelationships among methods of estimating microbial biomass across multiple soil orders and biomes: Supporting data

This dataset contains environmental and soil measurements from 18 different locations across the globe including the SPRUCE experiment site and multiple sampling depths, with 17 of these locations having samples processed between 2012-2013 and one location (SPRUCE) collected in 2021 and processed in 2022. Environmental measurements include: mean annual temperature, mean annual precipitation, and 30-day presampling temperature. Soil physicochemical measurements include: particle size analysis (PSA), pH, gravimetric moisture content (GMC), bulk soil carbon (C) and nitrogen (N), total organic C and N, C:N ratio, and dissolved organic carbon (DOC). Soil biological measurements include: microbial biomass carbon (MBC) measured through chloroform fumigation extraction (CFE), gene copy numbers (GCN) of bacteria, fungi, and archaea measured through quantitative polymerase chain reaction (qPCR), DNA yield measured through Nanodrop spectrophotometry, and phospholipid fatty acids (PLFA) of bacteria and fungi measured through PLFA analysis. This data set contains one file in comma separate (*.csv) format.

archaea gene copy number↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ba +2 ion trapping using organic submonolayer for ultra-low background neutrinoless double beta detector

If neutrinos are their own antiparticles the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay can occur. The very long lifetime expected for these exceptional events makes its detection a daunting task. In order to conduct an almost background-free experiment, the NEXT collaboration is investigating novel synthetic molecular sensors that may capture the Ba dication produced in the decay of certain Xe isotopes in a high-pressure gas experiment. The use of such molecular detectors immobilized on surfaces must be explored in the ultra-dry environment of a xenon gas chamber. Here, using a combination of highly sensitive surface science techniques in ultra-high vacuum, we demonstrate the possibility of employing the so-called Fluorescent Bicolor Indicator as the molecular component of the sensor. We unravel the ion capture process for these molecular indicators immobilized on a surface and explain the origin of the emission fluorescence shift associated to the ion trapping.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

The CLAS12 superconducting magnets

As part of the Jefferson Lab 12 GeV upgrade, the Hall B CLAS12 system requires two superconducting iron-free magnets — a torus and a solenoid. The physics requirements to maximize space for the detectors guided engineers toward particular coil designs for each of the magnets which, in turn, led to the choice of using conduction cooling. The torus consists of 6 trapezoidal NbTi coils connected in series with an operating current of 3770 A. The solenoid is an actively shielded 5 T magnet consisting of 5 NbTi coils connected in series operating at 2416 A. Within the hall, the two magnets are located in close proximity to each other and are completely covered both inside and outside by particle detectors. Stringent size limitations were imposed for both magnets and introduced particular design and fabrication challenges. This paper describes the design, construction, installation, commissioning, and operation of the two magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The CLAS12 Forward Tagger

This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of a Diffuser on Conditioning Flow Field Fluctuations at the Exit of a Rotating Detonation Combustor

Pressure gain combustion (PGC) seeks to convert fuel’s chemical energy simultaneously into thermal energy and mechanical energy, thereby reducing the entropy production in the process. Recent research has shown that the rotating detonation combustion or combustor (RDC) can provide excellent specific thrust, specific impulse, and large pressure gain through rapid energy release by continuous detonation in the circumferential direction. In this study, we present experimental results from RDC operated on methane and oxygen-enriched air to represent reactants used in gas turbines for land-based power generation. A thorough understanding of the velocity flow field exiting the combustor is important to develop future rotating detonation engine (RDE) designs, as well as to successfully implement the flow conditioning devices to power generating turbine hardware located downstream. The RDC is operated at high pressures in two ways through this study: 1) placing a back-pressure plate (BPP) downstream of the annular combustor, and 2) placing a diffuser downstream of the annular combustor. Time-resolved particle image velocimetry (TR-PIV) is applied at a frame rate of 50 kHz to quantify the RDC exit flow. A qualitative analysis is presented with vector data obtain from experimental testing. Results show that for the BPP configuration the highly periodic exit flow tilts in the azimuthal direction, indicating a significant circumferential velocity component. For the diffuser configuration the flow is dominantly axial, with an insignificant circumferential velocity component. The flow field undergoes cyclic fluctuations with the BPP, but not so with the diffuser. Results also show the challenges associated with achieving uniform seed distribution in this highly transient and rapidly changing flow field.

03 NATURAL GAS↗

High-Field Magnetoresistance of Organic Semiconductors

The magnetoelectronic field effects in organic semiconductors at high magnetic fields are described by field-dependent mixing between singlet and triplet states of weakly bound charge-carrier pairs due to small differences in their Landé g factors that arise from the weak spin-orbit coupling in the material. In this work, we corroborate theoretical models for the high-field magnetoresistance of organic semiconductors, in particular of diodes made of the conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrene-sulfonate) (PEDOT:PSS) at low temperatures, by conducting magnetoresistance measurements along with multifrequency continuous-wave electrically detected magnetic-resonance experiments. The measurements are performed on identical devices under similar conditions in order to independently assess the magnetic-field-dependent spin-mixing mechanism, the so-called Δg mechanism. Finally, an understanding of the microscopic origin of magnetoresistance in organic semiconductors is crucial for developing reliable magnetometer devices capable of operating over a broad range of magnetic fields of order 10 -7 - 10 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The SLAC Injector

Explore the source record for details and available documents.

Miller, R.↗