Engineering Papers⌕ Search

Engineering topics

Miller, James C.

Publications and source records attributed to Miller, James C..

Autonomic physiological data associated with simulator discomfort

A physiological monitoring capability was developed for the Army's Crew Station Research and Development Facility (CSRDF), a research simulator for advanced rotorcraft. Preliminary physiological data are reported from studies of simulator-induced sickness. Our objective was to demonstrate sensitivity of physiological measures relative to self-reports of simulator sickness severity. The data suggested that heart period, tachygastria, and skin conductance level were more sensitive to simulator sickness than were vagal tone and normal myoelectrical gastric activity.

Miller, James C.↗

Autonomic physiological data associated with simulator discomfort

The development of a physiological monitoring capability for the Army's advanced helicopter simulator facility is reported. Additionally, preliminary physiological data is presented. Our objective was to demonstrate the sensitivity of physiological measures in this simulator to self-reported simulator sickness. The data suggested that heart period, hypergastria, and skin conductance level were more sensitive to simulator sickness than were vagal tone and normal electrogastric activity.

Miller, James C.↗

A demonstration of motion base design alternatives for the National Advanced Driving Simulator

A demonstration of the capability of NASA's Vertical Motion Simulator to simulate two alternative motion base designs for the National Advanced Driving simulator (NADS) is reported. The VMS is located at ARC. The motion base conditions used in this demonstration were as follows: (1) a large translational motion base; and (2) a motion base design with limited translational capability. The latter had translational capability representative of a typical synergistic motion platform. These alternatives were selected to test the prediction that large amplitude translational motion would result in a lower incidence or severity of simulator induced sickness (SIS) than would a limited translational motion base. A total of 10 drivers performed two tasks, slaloms and quick-stops, using each of the motion bases. Physiological, objective, and subjective measures were collected. No reliable differences in SIS between the motion base conditions was found in this demonstration. However, in light of the cost considerations and engineering challenges associated with implementing a large translation motion base, performance of a formal study is recommended.

Mccauley, Michael E.↗