The fragmentation of 510 MeV/nucleon iron-56 in polyethylene. I. Fragment fluence spectra

The fragmentation of 510 MeV/nucleon iron ions in several thicknesses of polyethylene has been measured. Non-interacting primary beam particles and fragments have been identified and their LETs calculated by measuring ionization energy loss in a stack of silicon detectors. Fluences, normalized to the incident beam intensity and corrected for detector effects, are presented for each fragment charge and target. Histograms of fluence as a function of LET are also presented. Some implications of these data for measurements of the biological effects of heavy ions are discussed.

NASA Center HQS

NUCFRG2: An evaluation of the semiempirical nuclear fragmentation database

A semiempirical abrasion-ablation model has been successful in generating a large nuclear database for the study of high charge and energy (HZE) ion beams, radiation physics, and galactic cosmic ray shielding. The cross sections that are generated are compared with measured HZE fragmentation data from various experimental groups. A research program for improvement of the database generator is also discussed.

Wilson, J. W.

A Green's function method for heavy ion beam transport

The use of Green's function has played a fundamental role in transport calculations for high-charge high-energy (HZE) ions. Two recent developments have greatly advanced the practical aspects of implementation of these methods. The first was the formulation of a closed-form solution as a multiple fragmentation perturbation series. The second was the effective summation of the closed-form solution through nonperturbative techniques. The nonperturbative methods have been recently extended to an inhomogeneous, two-layer transport media to simulate the lead scattering foil present in the Lawrence Berkeley Laboratories (LBL) biomedical beam line used for cancer therapy. Such inhomogeneous codes are necessary for astronaut shielding in space. The transport codes utilize the Langley Research Center atomic and nuclear database. Transport code and database evaluation are performed by comparison with experiments performed at the LBL Bevalac facility using 670 A MeV 20Ne and 600 A MeV 56Fe ion beams. The comparison with a time-of-flight and delta E detector measurement for the 20Ne beam and the plastic nuclear track detectors for 56Fe show agreement up to 35%-40% in water and aluminium targets, respectively.

NASA Discipline Radiation Health

Nonperturbative methods in HZE propagation

An analytical solution to the perturbative multiple collision series of a fragmenting HZE ion beam has limited usefulness since the first collision term has several hundred contributions, the second collision term has tens of thousands of contributions, and each successive collision term progresses to unwieldy computational proportions. Our previous work has revealed the multiple collision terms in the straight-ahead approximation to be simple products of a spatially dependent factor times a linear energy-dependent factor of limited domain and unit normalization. The properties of these forms allow the development of the nonperturbative summation of the series to all orders assuming energy-independent nuclear cross sections as matrix products of a scaled Green's function described herein. This nonperturbative Green's function with multiple scattering correction factors compares well with experiments using 670 MeV/u neon-20 ion beams in thick water targets.

Non-NASA Center

The influence of dose, dose-rate and particle fragmentation on cataract induction by energetic iron ions

Because activities in space necessarily involve chronic exposure to a heterogeneous charged particle radiation field it is important to assess the influence of dose-rate and the possible modulating role of heavy particle fragmentation on biological systems. Using the well-studied cataract model, mice were exposed to plateau 600 MeV/amu Fe-56 ions either as acute or fractionated exposures at total doses of 5-504 cGy. Additional groups of mice received 20, 360 and 504 cGy behind 50 mm of polyethylene, which simulates body shielding. The reference radiation consisted of Co-60 gamma radiation. The animals were examined by slit lamp biomicroscopy over their three year life spans. In accordance with our previous observations with heavy particles, the cataractogenic potential of the 600 MeV/amu Fe-56 ions was greater than for low-Linear Energy Transfer (LET) radiation and increased with decreasing dose relative to gamma rays. Fractionation of a given dose of Fe-56 ions did not reduce the cataractogenicity of the radiation compared to the acute regimen. Fragmentation of the beam in the polyethylene did not alter the cataractotoxicity of the ions, either when administered singly or in fractions.

Medvedovsky, C.

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS

Orbit Determination of Hiten for Insertion into Lunar Orbit

This paper describes the JPL discovery of an integrated trajectory, and the tracking and orbit determination suuport provided by JPL's Deep Space Network and Multimission Navigation Team in support of the final targeting for lunar insertion.

Hiten

[Genotoxic modification of nucleic acid bases and biological consequences of it. Review and prospects of experimental and computational investigations]

The review is presented of experimental and computational data on the influence of genotoxic modification of bases (deamination, alkylation, oxidation) on the structure and biological functioning of nucleic acids. Pathways are discussed for the influence of modification on coding properties of bases, on possible errors of nucleic acid biosynthesis, and on configurations of nucleotide mispairs. The atomic structure of nucleic acid fragments with modified bases and the role of base damages in mutagenesis and carcinogenesis are considered.

Non-NASA Center

Heavy-ion fragmentation studies in thick water absorbers

Proposed long-term space missions could expose crewmembers to significant fluxes of galactic cosmic radiation (GCR) particles and secondary particles created from nuclear collisions. An assessment of radiobiological risks is dependent upon an accurate description of the charged-particle radiation field inside the human body. As shield thickness increases and the incident ions are slowed, the production of secondary particles contributes an increasingly significant fraction of the total dose until eventually secondary particles become more important than the primary particles. The nuclear mean free path of the GCR ions (which usually have nuclear charge between 1 (protons) and 26 (iron), both inclusive) are comparable with thicknesses typical of spacecraft structures and the human body. Collisions in these media will create projectile and target fragments with charge less than that of the primary particle, and each interaction event can have a multiplicity of more than one emerging interaction product. Projectile fragments usually continue on with very nearly the velocity of the primary ion (the so-called straightahead approximation). Having sufficient energy, the fragments may collide with atomic nuclei in thick shields and create a second generation of fragments, and so on. Target fragments are emitted from a struck nucleus, usually with much lower energy than projectile fragments and nearly isotropically in the rest frame of the absorbing medium. The resulting spectrum of particles and their energy loss rates will be very different from that in the unshielded environment, will determine the radiobiological impact on exposed living tissues -- whether in space or in ground-based radiobiology experiments -- and will play an important role in radiation effects on microelectronics.

Shavers, M. R.

Applications of high-resolution remote sensing image data

There are many situations in which the image resolution of satellite data is insufficient to provide the detail required for resource management and environmental monitoring. This paper will focus on applications of high-resolution (0.4 to 10 m) airborne multispectral and imaging spectrometer data acquired in Canada using the MEIS II multispectral line imager and the PMI imaging spectrometer. Applications discussed will include forestry, mapping, and geobotany.

Strome, W. M.

The fragmentation of 670A MeV neon-20 as a function of depth in water. I. Experiment

We present the final analysis of an experiment to study the interaction of a beam of 670A MeV neon ions incident on a water column set to different thicknesses. The atomic number Z (and, in some cases, the isotopic mass A) of primary beam particles and of the products of nuclear interactions emerging from the water column close to the central axis of the beam was obtained for nuclei between Be (Z = 4) and Ne (Z = 10) using a time-of-flight telescope to measure the velocity and a set of silicon detectors to measure the energy loss of each particle. The fluence of particles of a given charge was obtained and normalized to the incident beam intensity. Corrections were made for accidental coincidences between multiple particles triggering the TOF telescope and for interactions in the detector. The background due to beam particles interacting in beam line elements upstream of the detector was calculated. Sources of experimental artifacts and background in particle identification experiments designed to characterize heavy ion beams for radiobiological research are summarized, and some of the difficulties inherent in this work are discussed. Complete tables of absolutely normalized fluence spectra as a function of LET are included for reference purposes.

NASA Discipline Radiation Health

The Alaska synthetic aperture radar (SAR) facility project

A receiving station for the acquisition and processing of spaceborne synthetic aperture radar (SAR) data is being established by the National Aeronautics and Space Administration (NASA) at the University of Alaska, Fairbanks. The data that will be received from a number of SAR satellites that are to be launched starting in 1990 will allow U.S. researchers to study sea ice, oceanographic and geological features, hydrological processes, glaciers, and vegetation cover in Alaska and its surrounding seas.

Carsey, F.

Chemical Bonding Technology: Direct Investigation of Interfacial Bonds

This is the third Flat-Plate Solar Array (FSA) Project document reporting on chemical bonding technology for terrestrial photovoltaic (PV) modules. The impetus for this work originated in the late 1970s when PV modules employing silicone encapsulation materials were undergoing delamination during outdoor exposure. At that time, manufacturers were not employing adhesion promoters and, hence, module interfaces in common with the silicone materials were only in physical contact and therefore easily prone to separation if, for example, water were to penetrate to the interfaces. Delamination with silicone materials virtually vanished when adhesion promoters, recommended by silicone manufacturers, were used. The activities related to the direct investigation of chemically bonded interfaces are described.

Koenig, J. L.

Thermal conductivity of pristine and brominated P-100 fibers

Thermal conductivity of brominated and pristine Union Carbide P-100 graphite fibers in the 30 to 160 C temperature range was determined by measuring thermal conductivities of graphite fiber epoxy composite samples and then excluding the epoxy contribution. A comparative thermal conductivity instrument was used to measure the thermal conductivity of the samples containing fibers. Results showed that the thermal conductivity values were 225 to 370 w/m-K and 215 to 340 w/m-K for pristine and brominated fibers, respectively. Furthermore, the thermal conductivity ratio of brominated to pristine P-100 fibers was 0.89, 0.91, and 0.92 at 55 to 80 C; 108 and 130 C, respectively. Such decrease in thermal conductivity results almost entirely from the 10 percent increase in fiber cross sectional area due to bromination. This result suggests that bromination effects on P-100 fiber structure is small, and that some structural changes, presumably the sharp-angled domain wall becomes less sharp, occurring in the 80 to 108 C temperature range.

Hung, C. C.

Measuring Rind Thickness on Polyurethane Foam

Nondestructive test determines rind thickness of polyurethane foam. Surface harness of foam measured by Shore durometer method: hardness on Shore D scale correlates well with rind thickness. Shore D hardness of 20, for example, indicates rind thickness of 0.04 inch (1 millimeter). New hardness test makes it easy to determine rind thickness of sample nondestructively and to adjust fabrication variables accordingly.

Johnson, C.