Engineering Papers⌕ Search

Engineering topics

Miller, Erin A.

Publications and source records attributed to Miller, Erin A..

At least 19 records

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods, systems, and computer-readable storage media for enhanced phase-contrast x-ray imaging

Systems and methods that directly image attenuation-based object grid, use a source grid to improve imaging of the object grid using a high-energy polychromatic source, and use a detector grid having gratings oriented substantially orthogonally to that of the object grid, can address artifacts and beam hardening effects that limit the quality and discriminatory power of high-energy x-ray imaging that includes phase contrast.

Miller, Erin A.↗

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗

Serial Moire scanning phase contrast x-ray imaging

Method include emitting x-rays from an x-ray source, directing a first portion of the x-rays through an object grating situated adjacent to an object while the object is scanned relative to the object grating along a scan direction, directing a second portion of the x-rays through the object and subsequently through a detector grating without transmitting through the object grating, wherein the object grating and detector grating are adjacently arranged in a field of view of the x-rays sequentially with respect to each other in the scan direction, and receiving the first portion transmitted through the object and object grating with a first portion of a detector and receiving the second portion transmitted through the object and the detector grating with a second portion of the detector adjacent to the first portion of the detector. Systems are also disclosed, along with related techniques for beam hardening correction.

Miller, Erin A.↗

Methods, systems, and computer-readable storage media for enhanced phase-contrast x-ray imaging

Systems and methods that directly image attenuation-based object grid, use a source grid to improve imaging of the object grid using a high-energy polychromatic source, and use a detector grid having gratings oriented substantially orthogonally to that of the object grid, can address artifacts and beam hardening effects that limit the quality and discriminatory power of high-energy x-ray imaging that includes phase contrast.

Miller, Erin A.↗

3D Tomography and Image Processing Using Fast Neutrons Final Report

This document is the final report for project OR16-ML-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons.” This project was motivated by the availability of three-dimensional (3D) tomographic neutron transmission and induced-reaction data following the development of associated-particle imaging (API) systems with two-dimensional (2D) or “area” neutron detectors such as the Advanced Portable Neutron Imaging System, which is capable of simultaneous measurement of transmission and induced-reaction neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Python Performance Prediction Package for the PGET instrument: User Guide

The Performance Prediction Package (PPP) is a software suite for generating radiation transport results, or leveraging existing transport results, to produce synthetic emission tomography measurements of spent nuclear fuel assemblies. Such synthetic data can be used to mimic specific measurements, and to systematically investigate detection capabilities. Possible uses for the tool include: • Instrument design • Predictive evaluation of observables prior to an inspection visit • Post-measurement assessment of measured data • Evaluation of unusual cases – closed containers with anomalous objects • Sensitivity studies for planning inspections • Sensitivity studies for diversion scenarios • Evaluation of analysis methods A scenario is defined with an assembly type, burnup, and cooling time; as well as assembly rotation angle and position relative to the PGET instrument. Pin-to-pin activity variations or a burnup gradient may be present, but in an inspection scenario these are unlikely to be specified. The measurement will specify a measurement time and a particular detector for detector response, and an optional empirical correction can further adjust the model to better mimic the measurement. The goal is to detect missing pins, or burnup anomalies consistent with a pin substituted with a fresh pin after partial burnup.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid Gamma Emission Tomography for the Verification of Unirradiated Fuel: A Viability Study

Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as unirradiated fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies are needed to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration. This paper describes the status of a viability study on the HGET concept, including: envisioned use-case scenarios and corresponding definitions of fuel assemblies; modeling framework based on Monte Carlo and deterministic transport methods, and its validation; quantitative assessment of candidate HGET signatures with a focus on prompt fission gamma rays and delayed fission gamma rays; a nominal HGETv1 instrument design; candidate HGET-specific tomographic reconstruction methods that fully incorporate declared information; and examples of simulation-based predictions of HGET performance.

Miller, Erin A.↗

Hybrid Gama Emission Tomography (HGET): FY16 Annual Report

Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying the Scientific Method of Cybersecurity Research

The cyber environment has rapidly evolved from a curiosity to an essential component of the contemporary world. As the cyber environment has expanded and become more complex, so have the nature of adversaries and styles of attacks. Today, cyber incidents are an expected part of life. As a result, cybersecurity research emerged to address adversarial attacks interfering with or preventing normal cyber activities. Historical response to cybersecurity attacks is heavily skewed to tactical responses with an emphasis on rapid recovery. While threat mitigation is important and can be time critical, a knowledge gap exists with respect to developing the science of cybersecurity. Such a science will enable the development and testing of theories that lead to understanding the broad sweep of cyber threats and the ability to assess trade-offs in sustaining network missions while mitigating attacks. The Asymmetric Resilient Cybersecurity Initiative at Pacific Northwest National Laboratory is a multi-year, multi-million dollar investment to develop approaches for shifting the advantage to the defender and sustaining the operability of systems under attack. The initiative established a Science Council to focus attention on the research process for cybersecurity. The Council shares science practices, critiques research plans, and aids in documenting and reporting reproducible research results. The Council members represent ecology, economics, statistics, physics, computational chemistry, microbiology and genetics, and geochemistry. This paper reports the initial work of the Science Council to implement the scientific method in cybersecurity research. The second section describes the scientific method. The third section in this paper discusses scientific practices for cybersecurity research. Section four describes initial impacts of applying the science practices to cybersecurity research.

Tardiff, Mark F.↗

Coupling among Microbial Communities, Biogeochemistry, and Mineralogy across Biogeochemical Facies

Physical properties of sediments are commonly used to define subsurface lithofacies and these same physical properties influence subsurface microbial communities. This suggests an (unexploited) opportunity to use the spatial distribution of facies to predict spatial variation in biogeochemically relevant microbial attributes. Here, we characterize three biogeochemical facies—oxidized, reduced, and transition—within one lithofacies and elucidate relationships among facies features and microbial community biomass, diversity, and community composition. Consistent with previous observations of biogeochemical hotspots at environmental transition zones, we find elevated biomass within a biogeochemical facies that occurred at the transition between oxidized and reduced biogeochemical facies. Microbial diversity—the number of microbial taxa—was lower within the reduced facies and was well-explained by a combination of pH and mineralogy. Null modeling revealed that microbial community composition was influenced by ecological selection imposed by redox state and mineralogy, possibly due to effects on nutrient availability or transport. As an illustrative case, we predict microbial biomass concentration across a three-dimensional spatial domain by coupling the spatial distribution of subsurface biogeochemical facies with biomass-facies relationships revealed here. We expect that merging such an approach with hydro-biogeochemical models will provide important constraints on simulated dynamics, thereby reducing uncertainty in model predictions.

Stegen, James C.↗

Effect of Biofouling on the Performance of Amidoxime-Based Polymeric Uranium Adsorbents

The Marine Science Laboratory at the Pacific Northwest National Laboratory evaluated the impact of biofouling on uranium adsorbent performance. A surface modified polyethylene adsorbent fiber provided by Oak Ridge National Laboratory, AF adsorbent, was tested either in the presence or absence of light to simulate deployment in shallow or deep marine environments. 42-day exposure tests in column and flume settings showed decreased uranium uptake by biofouling. Uranium uptake was reduced by up to 30 %, in the presence of simulated sunlight, which also increased biomass accumulation and altered the microbial community composition on the fibers. These results suggest that deployment below the photic zone would mitigate the effects of biofouling, resulting in greater yields of uranium extracted from seawater.

adsorbents↗

Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo

Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide an estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards adaptive, streaming analysis of x-ray tomography data

Temporal and spatial resolution of chemical imaging methodologies such as x-ray tomography are rapidly increasing, leading to more complex experimental procedures and fast growing data volumes. Automated analysis pipelines and big data analytics are becoming essential to effectively evaluate the results of such experiments. Offering those data techniques in an adaptive, streaming environment can further substantially improve the scientific discovery process, by enabling experimental control and steering based on the evaluation of emerging phenomena as they are observed by the experiment. Pacific Northwest National Laboratory (PNNL)’ Chemical Imaging Initiative (CII - http://imaging.pnnl.gov/ ) has worked since 2011 towards developing a framework that allows users to rapidly compose and customize high throughput experimental analysis pipelines for multiple instrument types. The framework, named ‘Rapid Experimental Analysis’ (REXAN) Framework [1], is based on the idea of reusable component libraries and utilizes the PNNL developed collaborative data management and analysis environment ‘Velo’, to provide a user friendly analysis and data management environment for experimental facilities. This article will, discuss the capabilities established for X-Ray tomography, discuss lessons learned, and provide an overview of our more recent work in the Analysis in Motion Initiative (AIM - http://aim.pnnl.gov/ ) at PNNL to provide REXAN capabilities in a streaming environment.

analysis framework↗

Detectors for Accelerator-Based Security Applications

We present of review of detector systems used in accelerator-based national security applications. In gen-eral, the detectors used for these applications are also used in passive measurements. The critical difference is that detector systems for accelerator-based applications in general need to discriminate beam-generated background from the intended signal. Typical techniques to remove background include shielding, timing, selection of sensitive materials, and choice of accelerator.

Warren, Glen A.↗

3D Imaging of Microbial Biofilms: Integration of Synchrotron Imaging and an Interactive Visualization Interface

Understanding the interactions of structured communities known as “biofilms” and other complex matrixes is possible through the X-ray micro tomography imaging of the biofilms. Feature detection and image processing for this type of data focuses on efficiently identifying and segmenting biofilms and bacteria in the datasets. The datasets are very large and often require manual interventions due to low contrast between objects and high noise levels. Thus new software is required for the effectual interpretation and analysis of the data. This work specifies the evolution and application of the ability to analyze and visualize high resolution X-ray micro tomography datasets.

Biofilm Viewer↗

Vulnerability of larval and juvenile white sturgeon to barotrauma: can they handle the pressure?

Techniques were developed to determine which life stages of fish are vulnerable to barotrauma from expansion of internal gases during decompression. Eggs, larvae and juvenile hatchery-reared white sturgeon (Acipenser transmontanus; up to 91 days post hatch; dph), were decompressed to assess vulnerability to barotrauma and identify initial swim bladder inflation. Barotrauma related injury and mortality were first observed 9 dph, on the same day as initial exogenous feeding. However, barotrauma related injury did not occur again until swim bladder inflation 75 dph (visible from necropsy and x-ray radiographs). Swim bladder inflation was not consistent among individuals, with only 44% being inflated 91 dph. Additionally, swim bladder inflation did not appear to be size dependent among fish ranging in total length from 61-153 mm at 91 dph. The use of a combination of decompression tests and x-ray radiography was validated as a method to determine initial swim bladder inflation and vulnerability to barotrauma. Extending these techniques to other species and life history stages would help to determine fish susceptibility to hydroturbine passage and aid in fish conservation.

barotrauma↗