Engineering Papers⌕ Search

Engineering topics

Milincic, R.

Publications and source records attributed to Milincic, R..

42 records · Page 3

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗

Ortho-positronium observation in the Double Chooz experiment

The Double Chooz experiment measures the neutrino mixing angle θ13 by detecting reactor ν¯e via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved measurements of the neutrino mixing angle θ 13 with the Double Chooz detector

The Double Chooz experiment presents improved measurements of the neutrino mixing angle θ13 using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect to previous publications, whereas the efficiency of the ν¯e signal has increased. The value of θ13 is measured to be sin22θ13=0.090+0.032-0.029 from a fit to the observed energy spectrum. Deviations from the reactor ν¯e prediction observed above a prompt signal energy of 4 MeV and possible explanations are also reported. A consistent value of θ13 is obtained from a fit to the observed rate as a function of the reactor power independently of the spectrum shape and background estimation, demonstrating the robustness of the θ13 measurement despite the observed distortion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White paper: CeLAND - Investigation of the reactor antineutrino anomaly with an intense 144 Ce- 144 Pr antineutrino source in KamLAND

We propose to test for short baseline neutrino oscillations, implied by the recent reevaluation of the reactor antineutrino flux and by anomalous results from the gallium solar neutrino detectors. The test will consist of producing a 75 kCi 144 Ce - 144 Pr antineutrino source to be deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND). KamLAND's 13m diameter target volume provides a suitable environment to measure energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, "sterile" state. Such a measurement will be free of any reactor-related uncertainties. After 1.5 years of data taking the Reactor Antineutrino Anomaly parameter space will be tested at > 95% C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗