Engineering PapersSearch

Engineering topics

Miles, R. B.

Publications and source records attributed to Miles, R. B..

At least 19 records

Efficient vibrational Raman conversion in O2 and N2 cells by use of superfluorescence seeding

We report first-Stokes vibrational conversion efficiency of 21 percent and 35 percent, respectively, in high-pressure O2- and N2-stimulated Raman cells. Broadband superfluorescence is employed to seed these Raman cells, significantly increasing the conversion efficiences with no measured effect on the Raman spectrum. The addition of helium buffer gas reduces competition from stimulated Brillouin scattering and improves the pulse-to-pulse stability and spatial mode quality by increasing the thermal conductivity. Further improvement of the spatial mode quality is achieved by use of gentle heating on the bottom of the cell to induce convection.

Zhang, Barry

Velocity selective flow visualization in a free supersonic nitrogen jet with the resonant Doppler velocimeter

The use of the resonant Doppler velocimeter for flow visualization in a free supersonic nitrogen jet is demonstrated experimentally. In the experiment reported here, room-temperature nitrogen at 12.7 psi expands through a Mach 3.4 converging diverging nozzle into a plenum chamber; small amount of sodium is injected through a heated needle centered 0.5-in. upstream of the nozzle throat. The beam of a single frequency dye laser is expanded into a sheet of light with a cylindrical beam expander and directed counter to the jet to spatially resolve any slice across the core of the flow. By tuning the laser to different frequencies, particular velocity and density fields can be highlighted.

Zimmermann, M.

Evaluation of non-intrusive flow measurement techniques for a re-entry flight experiment

This study evaluates various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle orbiter or a similar reentry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser-Induced Fluorescence) light scattering, electron-beam fluorescence, thermal emission, and mass spectroscopy. Flow-field properties were taken from a nonequilibrium flow model by Shinn, Moss, and Simmonds at the NASA Langley Research Center. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.

Supersonic-nitrogen flow-field measurements with the resonant Doppler velocimeter

The application of the resonant Doppler velocimeter (RDV) for obtaining the mean velocity, temperature, and pressure measurements and flow-field visualization in a supersonic free nitrogen jet is reported. This method utilizes laser-induced fluorescence to determine the spectral absorption of an atomic or molecular species seeded into the flow. A narrow linewidth tunable laser is directed into the flow and the total fluorescence from any point is obtained as the laser is tuned. The velocity of the flow is obtained from the Doppler shifted absorption frequency, and the temperature and pressure of the gas are determined from line broadening measurements. Results are presented for the use of this technique to determine the velocity, temperature, and pressure of the flow of sodium atoms seeded into a supersonic nitrogen jet. It is concluded that the visible signal is sufficiently intense for spatially resolved flow visualization purposes.

Cheng, S.

Separation of time-averaged turbulence components by laser-induced fluorescence

A resonant Doppler velocimeter technique is introduced for time averaged gas flow turbulence fluctuation measurements. A monochrome laser beam is shone through a flow seeded with an atomic or molecular species that has an absorption frequency to which the laser is tuned. The resulting fluorescence is recorded by a detector, and the Doppler shift of the absorption frequency yields the velocity component of the flow in the direction of the beam. Static temperature and pressure data are available from the spectroscopic absoption line broadening. An analytical formulation of the laser-induced fluorescence intensity is defined and related to the velocity, temperature, and pressure. Comparison with data from a Na-seeded laminar supersonic jet demonstrates the accuracy of both the technique and model. Varying the pump laser frequency allows determination of the mean square velocity, temperature, and pressure fluctuations.

Cheng, S.

Non-intrusive flow measurements on a reentry vehicle

This study evaluates the utility of various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle or a similar re-entry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser Induced Fluorescence) light scattering, electron beam fluorescence, thermal emission and mass spectroscopy. Flow field properties are taken from a nonequilibrium flow model by Shinn, Moss and Simmonds at NASA Langley. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.

Turbulence measurements in high-speed flows by resonant fluoresence

Both mean flow and turbulence measurements were investigated using the resonant Doppler velocimeter in a Mach 3.2 nitrogen flow. Data are presented showing velocity, temperature and pressure measured point by point across the flow field. This data is compared with conventional pitot and temperature surveys. Turbulence was induced by a small metal tab in the flow and observed by both hot wire and RDV techniques. Photographs of the flow field demonstrate the utility of the RDV for quantitative flow field visualization.

Miles, R. B.

Hemispherical-field-of-view, nonimaging narrow-band spectral filter

Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

Miles, R. B.

Wide field of view laser beacon system for three-dimensional aircraft position measurement

This paper presents a new wide field of view laser beacon system for measurement, in three dimensions, of aircraft or other remote objects. The system is developed for aircraft collision hazard warning independent of ground-based hardware, as well as for flight research, helicopter-assisted construction and rescue, and robotic manipulation applications. Accurate information describing the relative range, elevation, and azimuth of the aircraft are generated by the sweep of a low-power fan-shaped rotating laser beacon past an array of optical detectors. The system achieves a wide angle of acceptance of laser beacon light through use of compound parabolic concentrators, which collimate the light for spectral filtering to minimize solar interference. An on-board microprocessor system converts the pulse sequence to aircraft position in real time. System reliability and performance are enhanced through narrow pass filtering of the pulse signals, digital logic design to mask spurious signals, and adaptive modulation of trigger threshold levels.

Sweet, L. M.

Laser beacon collision avoidance systems

The development objectives for a laser beacon collision avoidance system are outlined. A system suitable to general aviation aircraft is briefly described.

Sweet, L. M.

Low-temperature He-Na collision rate measurements

The foreign-gas collision broadening of the Na D2 line by He at a temperature of 8 K is measured. These data combined with those of other investigators provide an empirical scaling of the collision rates and cross sections over a wide range of temperatures and relative velocities, respectively.

Zimmermann, M.

Digital detection and processing of laser beacon signals for aircraft collision hazard warning

A low-cost collision hazard warning system suitable for implementation in both general and commercial aviation is presented. Laser beacon systems are used as sources of accurate relative position information that are not dependent on communication between aircraft or with the ground. The beacon system consists of a rotating low-power laser beacon, detector arrays with special optics for wide angle acceptance and filtering of solar background light, microprocessors for proximity and relative trajectory computation, and pilot displays of potential hazards. The laser beacon system provides direct measurements of relative aircraft positions; using optimal nonlinear estimation theory, the measurements resulting from the current beacon sweep are combined with previous data to provide the best estimate of aircraft proximity, heading, minimium passing distance, and time to closest approach.

Sweet, L. M.

Hypersonic-helium-flow-field measurements with the resonant Doppler velocimeter

A low density of sodium atoms seeded into a hypersonic helium flow is used to quantitatively determine flow-field properties. By observing fluorescence from a point as a single-mode dye laser is tuned through the sodium D2 line, the absorption profile may be found. This profile is fitted to a properly weighted sum of Voigt functions to yield the velocity, temperature, and pressure at the observation point. The fluorescence is strong enough to use this technique for qualitative flow-field visualization.

Zimmermann, M.

The semiconductivity and stability of palladium oxide

Palladium metal films are prepared on quartz substrates by RF sputtering from a pure palladium target in an argon atmosphere. These films are then oxidized in air or in an oxygen atmosphere at 700 C for periods between 24 hr and 6 days. Either treatment is found to produce good-quality thin films of PdO with a uniform orange transmission. Attention is focused on optical and electrical conductivity measurements made on PdO films with a view toward determining their band gap, conductivity and thermal stability in vacuum and in the presence of oxygen. It is shown that hydrogen greatly reduces the thermal stability of PdO. The film decomposes to Pd metal by 350 K in the presence of hydrogen as compared to a temperature of about 580 K in vacuum.

Rey, E.

Photocatalytic generation of hydrogen from water

A concept designed to overcome the problems encountered when using photodissociation for the generation of hydrogen is discussed. The problems limiting the efficiency of photodissociation of water are the separation of the photolysis products and the high energy photons necessary for the reaction. It is shown that the dissociation energy of a large number of molecules is catalytically reduced when these molecules are in intimate contact with the surface of certain metals. It is proposed to develop a surface which will take advantage of this catalytic shift in dissociation energies to reduce the photon energy required to produce hydrogen. This same catalytic surface can be used to separate the reaction products if it is made so that one of the dissociations products is soluble in the metal and others are not. This condition is met by many metal systems such as platinum group metals which have been used commercially to separate hydrogen from other gases and liquids.

Bottoms, W. R.

Resonant Doppler velocimeter

Narrow linewidth tunable lasers augur a new kind of laser Doppler velocimetry employing resonant absorption and fluorescence from trace atomic species rather than scattering from particles. This technique may provide better turbulence and small volume information than present velocimetry.

Miles, R. B.

Third-harmonic generation in phase-matched Rb vapor.

The generation of 0.3547-micron radiation was performed by tripling 1.064-micron radiation in a phase-matched mixture of rubidium vapor and xenon. A third-harmonic nonlinear susceptibility in Rb vapor is confirmed. It is about 100,000 times greater than that of He. This large susceptibility is due to the large oscillator strengths and resonant enhancements resulting from Rb transitions in the near infrared, visible, and UV.

Young, J. F.