Engineering Papers⌕ Search

Engineering topics

Meyer, Kent A

Publications and source records attributed to Meyer, Kent A.

Nanoscale Chemical Imaging of Zinc Oxide Nanowire Corrosion

Nanoscale chemical images of individual bare and alumina-coated zinc oxide nanowires (NWs) were recorded using tip-enhanced second harmonic generation (SHG) spectroscopy before and after exposure to carbon dioxide and water vapor. The NWs were exposed for 0, 2, 4 and 6 days, and images were collected for the same bare nanowire after each two-day exposure period. Corrosion of the bare ZnO NW to zinc carbonate was evident from far-field and near-field SHG images and simultaneously recorded AFM data. The expected zinc carbonate corrosion product is SHG inactive. The AFM profile of the NW showed vertical and lateral expansion in different regions of the nanowire. The lower resolution far-field SHG signal decreased gradually and uniformly. The near-field SHG signal provided a profile of the evolving NW under investigation with a spatial resolution of ~100 nm which is in agreement with the AFM results. In contrast, alumina-coated ZnO NWs that were exposed in the same gas environment showed reduced, but still observable, degradation. The 3-nm thick alumina protective layer may have been insufficient to fully protect the NW, or the coating may have been incomplete. Thicker coatings preclude the tip-enhanced method. Nevertheless, the ability to monitor corrosion on a nanometer scale is a powerful tool for a fundamental understanding of surface chemical processes and should lead to the discovery of protective layers to prevent or delay degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SURFACE COATING EFFECTS ON THE ASSEMBLY OF GOLD NANOSPHERES

Optical spectra and atomic force microscopy (AFM) images of individually selected spheres and mechanically assembled silica-coated gold nanosphere pairs were recorded. The 10-nm spacing of the spheres allowed discrete dipole approximation (DDA) computational simulations to provide a meaningful results regarding the dimers. Both the data and simulation indicate that the silica shell integrity was maintained throughout the assembly, so that the shell therefore served as a means of rigid control of the spacing between the metal cores. Optical perturbative effects due to the presence of the fused silica substrate were negligible. Experimental investigations regarding less rigid polyvinylpyrrolidone (PVP) coatings also were performed and some comparisons were made.

36 MATERIALS SCIENCE↗

Combined Apertureless Near-Field Optical Seconde-Harmonic Generation/Atomic Force Microscopy Imaging and Nanoscale Limit of Detection

A dual atomic force/near-field scanning optical microscope (AFM/NSOM) with an 800-nm ultrafast laser excitation source was used to investigate apertureless, tip-enhanced second harmonic generation (SHG) of ZnO nanowires. Data from far-field single-particle SHG microscopy images and spectra show little to no contributions from band-gap or other emission. The SHG microscope image and the simultaneous tapping mode AFM and apertureless SHG NSOM images indicate that ZnO nanowires exhibit a strong SHG signal consistent with uniform crystallinity, whereas other ZnO particles found with the wires had a variable, weaker SHG signal. Polarization data established values for Chi(33)/Chi(31) close to previous estimates. Our AFM/SHG NSOM data suggest a particle degradation mechanism under atmospheric conditions starting at the endpoints of the nanowire.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combined Chemical and Topographic Imaging at Atmospheric Pressure via Microprobe Laser Desorption/Ionization Mass Spectrometry-Atomic Force Microscopy

The operational characteristics and imaging performance are described for a new instrument comprising an atomic force microscope (AFM) coupled with a pulsed laser and a linear ion trap mass spectrometer. The AFM operating mode is used to produce topographic surface images having nanometer-scale spatial and height resolution. Spatially resolved mass spectra of ions, produced from the same surface via microprobe-mode laser desorption/ionization at atmospheric pressure, are then used to create a 100 x 100 m chemical image. The effective spatial resolution of the image (~2 m) was constrained by the limit of detection (estimated to be 109 1010 ions) rather than by the diameter of the focused laser spot or the step size of the AFM sample stage. Thus, it is expected that improvements in imaging performance can be realized by implementation of post-ionization methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational and Experimental Evaluation of Nanoparticle Coupling

We present theoretical and experimental studies on the optical properties of dimers composed of octahedron-shaped, gold nanoparticles. The experimental measurements show that the photoluminescence varies quite dramatically as two octahedra are brought into close proximity. AFM images and optical emission have been recorded for dimers in uncoupled and strongly coupled configurations. The former displays a single emission peak, while the latter shows two peaks with the new feature at longer wavelengths. Calculations indicate that the red-shifted peak originates from a strongly coupled plasmon state that oscillates along the extended axis of the dimer. Theoretically, we investigate the distances over which the dimers couple and find this to be particularly plasmon mode dependent. The anisotropic morphology and sharp apexes contribute significantly to the orientational dependence of the interparticle couplings and field properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a scanning surface probe for nanoscal tip-enhanced desorption/ablation

We report on the development of a versatile scanning apparatus for nanoscale surface sampling that utilizes the interaction of laser radiation at a sharp probe tip to effect desorption/ablation on opaque substrates. The process, which currently yields surface craters as small as ~50 nm diameter X5 nm deep, has been demonstrated with both metal-coated and bare silicon tips. Desorption/ablation under the tip occurs at illumination intensities below the corresponding optical far-field threshold, suggesting that the latter process should not degrade the spatial resolution attainable for proposed chemical imaging methods based on the scanning surface probe.

47 OTHER INSTRUMENTATION↗

Observation of spectral asymmetry in cw-pumped type II spontaneous parametric down-conversion

We report on a spectral asymmetry in cw-pumped type II spontaneous parametric down-conversion. We observe that when the pump beam is focused, the spectra of ordinary and extraordinary down-converted photons broaden unequally. Theoretical analysis indicates that this asymmetry can be attributed to the difference in the angular dispersion (walk-off) of the two kinds of photons, coupled with the well-known correlation between wavelength and emission direction.

quantum optics↗

Optical Absorption Measurements with Parametric Down-Converted Photons

It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗