Engineering Papers⌕ Search

Engineering topics

Mentzer, Heather

Publications and source records attributed to Mentzer, Heather.

Tritium cleanup system and method

Work area cleanup systems and methods are described for removing tritium from the atmosphere of a work area such as inert gas gloveboxes. Systems utilize a multi-column approach with parallel processing. Tritium of a tritium-contaminated stream is converted into tritiated water and adsorbed onto the separation phase of a first column as a second, parallel column can be simultaneously regenerated. The gaseous stream that exits the column during the regeneration phase can carry a high tritium concentration. The system can also include and a separation stage during which the tritium of the gaseous regeneration stream can be separated from the remainder of the regeneration product.

Xiao, Xin↗

Water and Ammonia Desorption from 5A Zeolite

Demonstrate adsorption and desorption characteristics of water and ammonia on 5A zeolite during regeneration conditions using a Thermogravimetric analyzer (TGA) on samples previously evaluated by residual gas analyzer (RGA)/mass balance. Molecular sieve (zeolite) adsorbents have the following characteristics: Crystalline alumino-silicates containing pores or 'cages' that adsorb water or other molecules. Polar compound are adsorbed with high loading even at very low concentrations of the fluid. A 5A molecular sieve was chosen for its ability to adsorb both water and ammonia (NH{sub 3}) from a carrier gas stream. Preliminary RGA/mass balance testing indicated: 5A zeolite captured both NH{sub 3} and water as anticipated based on molecular size; Reloading showed limited success after zeolite heated beyond manufacturer recommended operating conditions: Steam dealumination theorized cause; Tests were reprioritized to focus on NH{sub 3} removal and end of life potential holdup of NH{sub 3} and water on 5A zeolite material. TGA measures a sample's weight and volatile composition as it is heated or cooled in a furnace. TGA heats sample to release volatile materials, (change in mass is measured). MS detects/measures low levels of impurities. Perform TGA desorption of zeolite samples taken at the following conditions tested with RGA (RGA results not shown here): Initial Bakeout conditions: hydrogen carrier gas, slowly raise temp to approximately 300 deg. C until desired moisture content <<100 ppm is achieved. Water loading (re-loading): argon carrier gas through bubbler until breach is observed. Ammonia loading (re-loading): hydrogen carrier gas through system. Regenerations/End of life conditions: hydrogen carrier gas, raise temp to approximately 300 deg. C, then slowly to 450 deg. C (end of life). After end of life testing less than 4% of the total mass was residual ammonia or water at bakeout conditions. Peak water and ammonia removal occurred around 275 deg. C and 150 deg. C respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water and Ammonia Desorption from 5A Zeolite

The objective of this project is to demonstrate the adsorption and desorption characteristics of water and ammonia on 5A zeolite during regeneration conditions. As discussed in literature, zeolite material is a crystalline hydrated aluminosilicate material. Zeolites have high cation exchange ability and are commonly used as adsorbents in separation and purification processes. The property of uniformly sized pores allows zeolites to selectively separate gases. Because they have varying ion selectivity, there is competitive adsorption in a multicomponent mixture. 5A zeolite has a uniform pore diameter of 5 Angstroms. Water and ammonia are miscible components with similar molecular weights and size. This makes distinguishing the two compounds difficult using mass spectrometry. In a previous study, it was shown that water tends to desorb from 5A zeolite from 40 deg. C to 353 deg. C with peaks at 177 deg. C and 244 deg. C, while ammonia tends to desorb from 300 deg. C to 580 deg. C with a peak at 436 deg. C as determined using a Micromeritics AutoChem 2920 Instrument. The one drawback of using a Micromeritics Instrument is that only a few milligrams of sample material can be used. Bench scale tests can better demonstrate desorption characteristics of water and ammonia during regeneration from 5A zeolite material. Water in argon carrier gas and ammonia in hydrogen carrier gas will be tested separately, then a mixture of the two will be tested. Initial bake-out conditions: hydrogen carrier gas, slowly raise temp to approximately 450 deg. C until desired moisture content <100 ppm is achieved. Water loading: argon carrier gas through bubbler until breach is observed using the residual gas analyzer (RGA). Ammonia loading: hydrogen carrier gas through system until breach is observed using RGA. Regeneration conditions: hydrogen carrier gas, raise temp to approximately 300 deg. C, then slowly to 450 deg. C. Observe signals on RGA. Weigh samples between tests and integrate RGA signals. Accomplishments: Developed work control documentation and completed safety related requirements; Flow sheet and test system development; Initial bake-out of first sample. Testing will determine if regenerating zeolite material can be safely accomplished by high-temperature bake-out to remove ammonia. If unsuccessful, ammonia would only be removed at the end of life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗