Mckelvey, M. E.

Publications and source records attributed to Mckelvey, M. E..

Evaluation of a 256 x 256 Si:As IBC detector array for astronomy

256 x 256-element IBC Si:As arrays have been evaluated for applications in IR astronomy from space-borne platforms. Basic figures of merit were measured at IR flux levels simulating those expected in space-based astronomical observations. Results include dark current less than 20 e(-)/s, G-eta as high as 3.8, eta/beta of 20%, and read noise below 100 rms(e(-)).

Mckelvey, M. E.↗

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

Low-background detector arrays for infrared astronomy

The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.

Mccreight, C. R.↗

Detector Arrays For Infrared Astronomy

Paper describes status of program for developing integrated infrared detectors for astronomy. Program covers variety of detectors, including extrinsic silicon, extrinsic germanium, and indium antimonide devices with hybrid silicon multiplexers. Paper notes for arrays to reach background noise limit in cryogenic telescope, continued reductions in readout noise and dark current needed.

Mccreight, C. R.↗

Performance Of Infrared-Detector Array

Report describes design, characteristics, and performance of Si:Sb integrated array of infrared detectors, sensitivity of which extends to wavelength of about 31 micrometer, improvement over 28-micrometer limit of current Si:As impurity-band-conduction devices. Also describes electronics and special Dewar system developed to test device at low temperature to reduce background noise.

Goebel, J. H.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratory test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Low-background direct readout array performance

The development and evaluation of an integrated array of antimony-doped silicon detectors is described. The spectral range of extrinsic silicon-integrated arrays useful for low-background IR astronomical applications is extended to about 31 microns with this development. The 58 x 62-element array is accessed by a direct readout multiplexer. The device is evaluated with a flexible microcomputer-based drive and readout electronics system in a low-background test dewar. Acceptance testing indicates single-pixel NEPs in the mid-10 to the -18th W/sq rt Hz range, and good global uniformity statistics.

Goebel, J. H.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratary test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Charge-injection-device 2 x 64 element infrared array performance

Three 2 x 64 element Si:Bi accumulation-mode charge-injection-device (CID) arrays were tested at low and moderate background to evaluate their usefulness for space-based astronomical observations. Testing was conducted both in the laboratory and in ground-based telescope IR observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3 x 10 to the -17th W/sq rt Hz. This sensitivity compares well with that of nonintegrating discrete extrinsic silicon photoconductors. The array well capacity was significantly smaller than predicted. The measured sensitivity makes extrinsic silicon CID arrays useful for certain astronomical applications. However, their readout efficiency and frequency response represent serious limitations in low-background applications.

Mckelvey, M. E.↗

Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds

Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.

Mckelvey, M. E.↗

Integrated detector array technology for infrared astronomy

The status of laboratory and telescope tests of integrated infrared detector array technology for astronomical applications is described. The devices tested represent a number of extrinsic and intrinsic detector materials and various multiplexer designs. Infrared arrays have now been used in successful astronomical applications. These have shown that device sensitivities can be comparable to those of discrete detector systems and excellent astronomical imagery can be produced.

Mccreight, c. R.↗

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.↗