Engineering PapersSearch

Engineering topics

Mccreight, C. R.

Publications and source records attributed to Mccreight, C. R..

At least 37 records · Page 2

Narrow band imagery in the 8-14 micron spectral region

The problem of deconvolution of the point source response function (PSF) for two-dimensional imaging infrared arrays is addressed. A variety of phenomena can lead to PSF degradation, ranging from atmospheric turbulence to the array itself. The maximum entropy algorithm is used to demonstrate that substantial image quality improvements are possible in the case of a PSF which is degraded by electronic rather than optical smearing. This result implies that IR arrays need not have perfect or even very good pixel-pixel crosstalk rejection ratios for use in astronomy.

Goebel, J. H.

Charge-injection-device 2 x 64 element infrared array performance

Three 2 x 64 element Si:Bi accumulation-mode charge-injection-device (CID) arrays were tested at low and moderate background to evaluate their usefulness for space-based astronomical observations. Testing was conducted both in the laboratory and in ground-based telescope IR observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3 x 10 to the -17th W/sq rt Hz. This sensitivity compares well with that of nonintegrating discrete extrinsic silicon photoconductors. The array well capacity was significantly smaller than predicted. The measured sensitivity makes extrinsic silicon CID arrays useful for certain astronomical applications. However, their readout efficiency and frequency response represent serious limitations in low-background applications.

Mckelvey, M. E.

The 8.3 and 12.4 micron imaging of the Galactic Center source complex with the Goddard infrared array camera

A 30 x 30 arcsec field at the Galactic Center (1.5 x 1.5 parsec) was mapped at 8.3 microns and 12.41 microns with high spatial resolution and accurate relative astrometry, using the 16 x 16 Si:Bi accumulation mode charge injection device Goddard infrared array camera. The design and performance of the array camera detector electronics system and image data processing techniques are discussed. Color temperature and dust opacity distributions derived from the spatially accurate images indicate that the compact infrared sources and the large scale ridge structure are bounded by warmer, more diffuse material. None of the objects appear to be heated appreciably by internal luminosity sources. These results are consistent with the model proposing that the complex is heated externally by a strong luminosity source at the Galactic Center, which dominates the energetics of the inner few parsecs of the galaxy.

Gezari, D. Y.

Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds

Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.

Mckelvey, M. E.

Photometric imaging near infrared spectrometer

A description of the design and performance of an imaging spectrometer intended for operation in the seven to fourteen micrometer wavelength range is presented. It is based upon a sixteen by sixteen element Si:Bi hybrid array, a circular variable filter wheel, and a microcomputer data acquisition system. The spatial-spectral photometric performances have been evaluated in the laboratory as well as field tested at astronomical observatories. The performance characteristics of the system are presented as well as laboratory and astronomical images.

Goebel, J. H.

Low-temperature heat pipe experiment package (HEPP) for LDEF (S1001)

The principal objectives of the experiment are to determine zero-g start-up performance for conventional and diode low temperature heat pipes, to evaluate heat pipe performance in zero-g for an extended period of time, to determine zero-g transport capability of each heat pipe, and to determine diode operation, including forward conductance, turndown ratio, and transient behavior. Two heat pipes, a fixed conductance transporter heat pipe and a thermal diode heat pipe, are coupled with a radiant cooler system. Both pipes are charged with ethane. Also integrated with the radiator is a phase change material (PCM) canister which provides temperature stability during transport tests. N-heptane, which has a melting/freezing point of 182 K, is used as the PCM. The high heat capacity (28 W-hr of latent heat) provided by the canister permits high power heat pipe testing at constant temperature.

Mcintosh, R., Jr.

Two-dimensional infrared detector arrays

An introduction to overall IR array concepts and particular array designs is presented, and examples of laboratory and observational data obtained with IR arrays are given. Hybrid array designs, extrinsic silicon accumulation-mode charge injection devices, and switched-FET or switched-sample photoconductor techniques are summarized. Three recent astronomical observation projects which used IR arrays are examined.

Mccreight, C. R.

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.

Brief characterization of germanium junction field effect transistors (FETs) at 77, 4, and 1.8 K

In the case of modern infrared focal planes, one of the major problems is related to the noise contribution of the cooled, impedance-matching device used as the preamplifier stage in the detector electronics system. An ideal preamp device should have the low-noise advantages of a buried-channel device and operate isothermally with the low-temperature detector array. The Ge JFET might provide this ideal device. A testing program with Ge JFETs is discussed. It is concluded that germanium JFETs offer an attractive alternative for cryogenic preamplifier designs. They operate well with high transconductance and low noise at LHe temperatures. It is believed that these devices point the way for the development of large, integrated-array, long wavelength, infrared focal planes which incorporate germanium detectors, germanium load resistors, and germanium preamplifiers within the same monolithic structure.

Arentz, R. F.

Low-background performance of a monolithic InSb CCD array

A 20 element monolithic InSb charge coupled device (CCD) detector array was measured under low background conditions to assess its potential for orbital astronomical applications. At a temperature of 64 K, previous results for charge transfer efficiency (CTE) were reproduced, and a sensitivity of about 2 x 10 to the minus 15th power joules was measured. At 27 and 6 K, extended integration times were achieved, but CTE was substantially degraded. The noise was approximately 6000 charges, which was in excess of the level where statistical fluctuations from the illumination could be detected. A telescope demonstration was performed showing that the array sensitivity and difficulty of operation were not substantially different from laboratory levels. Ways in which the device could be improved for astronomical applications were discussed.

Bregman, J. D.

Development and evaluation of integrated infrared arrays for astronomical applications

The status of a technology program to evaluate existing infrared detector arrays, and to develop improved ones for low background astronomical applications, is described. For applications such as the Shuttle Infrared Telescope Facility, arrays that cover as much of the 1-1000 micron range as possible are of interest. Low background test results for a 2 x 64 Si:Bi charge-injection-device, and 1 x 20 InSb charge-coupled-device arrays, are included. As a result of the present testing, improved, astronomy-optimized extrinsic silicon arrays in both linear and area formats are planned. Efforts to develop accumulation mode MOSFETs specifically for liquid helium temperatures, and cryogenic amplifier and multiplexer circuits, are discussed.

Mccreight, C. R.

Integrated infrared detector arrays for low-background applications

Advanced infrared detector and detector array technology is being developed and characterized for future NASA space astronomy applications. Si:Bi charge-injection-device arrays have been obtained, and low-background sensitivities comparable to that of good discrete detectors have been measured. Intrinsic arrays are being assessed, and laboratory and telescope data have been collected on a monolithic InSb CCD array. For wavelengths longer than 30 microns, improved Ge:Ga detectors have been produced, and steps have been taken to prove the feasibility of an integrated extrinsic germanium array. Other integrated arrays and cryogenic components are also under investigation.

Mccreight, C. R.

Infrared charge-injection-device array performance at low background

Low-background tests of a 1 x 32 Si:Bi charge-injection-device (CID) IR detector are carried out to evaluate its feasibility for space-based astronomical observations. Optimum performance is obtained at a temperature of 11 K. The sensitivity is found to compare well with that of discrete extrinsic silicon photoconductors. The measured sensitivity and the apparent absence of anomalous effects make extrinsic silicon CID arrays very promising for astronomical applications.

Mccreight, C. R.

Infrared receivers for low background astronomy: Incoherent detectors and coherent devices from one micrometer to one millimeter

The status of incoherent detectors and coherent receivers over the infrared wavelength range from one micrometer to one millimeter is described. General principles of infrared receivers are included, and photon detectors, bolometers, coherent receivers, and important supporting technologies are discussed, with emphasis on their suitability for low background astronomical applications. Broad recommendations are presented and specific opportunities are identified for development of improved devices.

Boggess, N. W.

Integrated infrared detector arrays for low-background astronomy

Existing integrated infrared detector array technology is being evaluated under low-background conditions to determine its applicability in orbiting astronomical applications where extended integration times and photometric accuracy are of interest. Preliminary performance results of a 1 x 20 elements InSb CCD array under simulated astronomical conditions are presented. Using the findings of these tests, improved linear- and area-array technology will be developed for use in NASA programs such as the Shuttle Infrared Telescope Facility. For wavelengths less than 30 microns, extrinsic silicon and intrinsic arrays with CCD readout will be evaluated and improved as required, while multiplexed arrays of Ge:Ga for wavelengths in the range 30 to 120 microns will be developed as fundamental understanding of this material improves. Future efforts will include development of improved drive and readout circuitry, and consideration of alternate multiplexing schemes.

Mccreight, C. R.

Integrated detector array preprocessing for infrared astronomical applications

On-board preprocessing of astronomical data from integrated infrared detector arrays and discrete detectors will allow increases in sensitivity and reductions in costs for observations from cryogenic space telescopes. A variety of preprocessing functions for this application, which could be implemented either through analog on-chip devices or through external microprocessors, is identified. Software simulations and laboratory evaluations are underway to determine the effectiveness of these preprocessing schemes.

Mccreight, C. R.

An investigation of heat pipe meniscus heat transfer

The use of grooved evaporator surfaces in heat pipes has increased in popularity in the past few years primarily due to the reproducibility achievable with grooved walls and the relatively low costs of the threading or extrusion processes involved in their production. The present study combines both analyses and experiments on square groove geometries, with special emphasis on overcoming the limitations of earlier analyses with finite-difference methods and groove-fillet hydrodynamic simplifications. The groove fillet, which has in previous analyses been assumed constant in radius of curvature, is permitted to change in thickness and curvature consistent with hydrodynamics and heat loss from the groove. A model is developed for accurate determination of the effect of constriction resistance on groove performance. The grooved-surface tests to be conducted are briefly described which will provide data under closely controlled operation to allow comparison and verification of the analyses.

Saaski, E. W.

Infrared Astronomical Satellite /IRAS/ and Shuttle Infrared Telescope Facility /SIRTF/ - Implications of scientific objectives on focal plane sensitivity requirements

The full potential of infrared astronomy can be realized only through observations made with space-based telescopes cooled to cryogenic temperatures. The paper outlines the scientific mission, system description, and focal plane requirements for two cryogenic telescopes: the Infrared Astronomical Satellite (IRAS) and the Shuttle Infrared Telescope Facility (SIRTF). IRAS, a 60-cm superfluid-helium-cooled telescope system, will perform a one-year 8-120-micron IR sky survey; it will provide results of high reliability and sensitivity, produce the first complete survey data for the 30-120-micron region, and fill in missing portions (spectrally and spatially) of previous surveys short of 30 microns; its focal plane assembly is being designed to approach background-limited performance with an array of 62 discrete detectors. The SIRTF design will allow detailed follow-up studies in the 1-1000-micron range with a 116-160-cm observatory-class instrument. The Shuttle sortie capability introduces the unique SIRTF concept of an easily refurbishable or replaceable focal plane instrument complement in an orbiting cryogenic telescope.

Mccreight, C. R.