Engineering Papers⌕ Search

Engineering topics

McIntosh, A. B.

Publications and source records attributed to McIntosh, A. B..

Using DAPPER to extract the photon strength function of 58Fe using the inverse Oslo and shape methods

The photon strength function of 58 Fe has been extracted using both the Oslo and Shape methods from particle-γ coincidence data measured using the Detector Array for Photons, Protons, and Exotic Residues, which probes nuclei utilizing (d,p) reactions in inverse kinematics. Four particle-γ coincidence matrices, each constructed with different treatments of the γ-ray energies, are explored in order to observe the impact on the resulting nuclear level density and photon strength. The final photon strength function reported is found to agree well with previous Oslo measurements of other iron isotopes. Systematic uncertainties are included, using different model parameters and their reported errors to perform the Oslo method normalization. The model-independent Shape method is explored and the functional form of the photon strength function obtained is in agreement with the Oslo method results. A low-energy enhancement is not reported for 58 Fe in this work given possible subtraction issues originating from strongly populated states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Apparent temperatures of neutron-poor and neutron-rich compound nuclei

The possibility of the dependence of the nuclear caloric curve on neutron excess sets a limit on the accuracy of our knowledge of the nuclear equation of state, and thus impacts predictive capabilities of nuclear reaction and nuclear astrophysics models. To date, theoretical models have not reached consensus on the magnitude or sign on the asymmetry dependence. To provide constraints, we have measured evaporated particles and heavy residues for complete and incomplete fusion-evaporation reactions in inverse kinematics. The temperatures extracted from the observed light charged particles tend to favor higher temperatures for the neutron-rich fused systems, though they are near the limits of the systematic uncertainty. The present measurement may be used as an upper limit to constrain the asymmetry dependence of the nuclear caloric curve.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the time dependence of neutron-proton equilibration using molecular dynamics simulations

Neutron-proton equilibration has previously been studied experimentally in dynamically deformed nuclei in heavy ion collisions [Phys. Rev. Lett. 118, 062501 (2017); Phys. Rev. C 95, 044604 (2017)] using the NIMROD detector array at the Cyclotron Institute at Texas A&M University. Results indicated the composition of the two heaviest fragments originating from the excited projectile-like fragment evolved exponential with respect to their orientation angle to be more similar. Constrained Molecular Dynamics and Antisymmetrized Molecular Dynamics simulations were performed for different formulations of the density dependence of the asymmetry energy term of the nuclear equation of state. The simulations are compared to experimental results, which indicate a better agreement with a softer interaction in the nuclear equation of state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton and neutron exchange as a prelude to fusion at near-barrier energies

Systematic examination of fusion for 39,41,45,47 K + 28 Si and 36,44 Ar + 28 Si provides insight into the impact of neutron and proton exchange on fusion for nuclei at and near the N = 20 and N = 28 shells. Comparison of the reduced excitation functions reveals a marked difference between the behavior of open-shell and closed-shell systems. While coupled channels calculations provide a good description for the closed-shell nuclei, they significantly underpredict the fusion cross section for open-shell nuclei. Furthermore, the observed trends are examined in the context of a potential energy surface, including shell effects, and multinucleon exchange with consideration of Pauli blocking.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of sCVD diamond detectors for low energy heavy-ion reactions

Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of shell structure on the fusion of neutron-rich mid-mass nuclei

The influence of shell effects on fusion of mid-mass nuclei is explored using isotopic chains of K and Ar ions on an oxygen target. Comparison of the reduced excitation functions reveals that the fusion cross section for the open neutron-shell projectile nuclei 41 K and 45 K is systematically larger than for the closed neutron-shell projectiles 39 K and 47 K. Furthermore, the São Paulo fusion model using matter densities from systematics fails to describe the measured excitation functions. Use of more realistic densities from a Dirac-Hartree-Bogoliubov (DHB) approach performs significantly better though it still overpredicts the closed-shell nuclei.

39 ≤ A ≤ 58↗

Rapidity distributions of Z = 1 isotopes and the nuclear symmetry energy from Sn+Sn collisions with radioactive beams at 270 MeV/nucleon

The rapidity distributions of hydrogen isotopes emitted from central collisions of neutron-rich 132 Sn+ 124 Sn and neutron-deficient 108 Sn+ 112 Sn systems at 270 MeV/nucleon were investigated at RIKEN-RIBF. The data are compared with antisymmetrized molecular dynamics (AMD) calculations and the rapidity distributions can be reproduced after adjusting the in-medium nucleon-nucleon cross sections. The double ratios between the two reaction systems taken for the relative yields of deuteron to proton (d/p) and triton to proton (t/p) are further examined in the midrapidity domain, where the adjustments in the AMD calculations do not affect much on them. The d/p and t/p double ratios at midrapidity agree well with the ratio of the system neutron numbers and its squared value, respectively, and the rapidity dependence of these double ratios is consistent with a picture of partial mixing of colliding nuclei. By comparing with the AMD model which shows a strong symmetry energy dependence of the t/p double ratio, the experimental result in the midrapidity domain favors the calculation with a symmetry-energy slope parameter around L = 46 MeV rather than L = 108 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advances in 211 At production at Texas A&M University

Alpha emitting radionuclides with medically relevant half-lives are interesting for treatment of tumors and other diseases because they deposit large amounts of energy close to the location of the radioisotope. Researchers at the Cyclotron Institute at Texas A&M University are developing a program to produce 211 At, an alpha emitter with a medically relevant half-life. Here, the properties of 211 At make it a great candidate for targeted alpha therapy for cancer due to its short half-life (7.2 h). Astatine-211 has now been produced multiple times and reliability of this process is being improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the Symmetry Energy with the Spectral Pion Ratio

Many neutron star (NS) properties, such as the proton fraction within a NS, reflect the symmetry energy contributions to the Equation of State that dominate when neutron and proton densities differ strongly. To constrain these contributions at supra-saturation densities, we measure the spectra of charged pions produced by colliding rare isotope tin (Sn) beams with isotopically enriched Sn targets. Here, using ratios of the charged pion spectra measured at high transverse momenta, we deduce the slope of the symmetry energy to be 42 < $L$ < 117 MeV. This value is slightly lower but consistent with the $L$ values deduced from a recent measurement of the neutron skin thickness of 208 Pb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlation between time and angular alignment in molecular dynamics simulations of heavy ion collisions

Neutron-proton equilibration is a process which has been used to study the density dependence of the symmetry energy term in the nuclear equation-of-state. Here, this study utilizes constrained molecular dynamics (CoMD) simulations of 70 Zn + 70 Zn with collision energies of 35 and 45 MeV/nucleon. An algorithm is used which searches through CoMD events and identifies the PLF* after it separates from the target and determines its lifetime, Δt. It also determines the fragments that the PLF* breaks apart into and determines their angular alignment. This technique gives an opportunity to explore how the average alignment of dynamically produced fragments, $\langle$α $\rangle$ dyn , evolves with PLF* lifetime. An approximately linear relationship was determined with d$\langle$α $\rangle$ dyn /dΔt = 0.98 ± 0.08 rad / zs and 1.06 ± 0.09 rad / zs for the 35 and 45 MeV / nucleon, respectively, indicating a correlation with magnitude consistent with classically determined values which were used for prior experimental studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗