Engineering Papers⌕ Search

Engineering topics

McGee, Thomas J.

Publications and source records attributed to McGee, Thomas J..

At least 19 records

Lidar Validation Measurements at the NOAA Mauna Loa Observatory NDACC Station

NASA's Goddard Space Flight Center (GSFC) transported two lidar instruments to the NOAA facility at the Mauna Loa Observatory (MLO) on the Big Island of Hawaii, to participate in an official, extended validation campaign. This site is situated 11,141 ft. above sea level on the side of the mountain. The observatory has been making atmospheric measurements regularly since the 1950's, and has hosted the GSFC Stratospheric Ozone (STROZ) Lidar and the GSFC Aerosol and Temperature (AT) Lidar on several occasions, most recently between November, 2012 and November, 2015. The purpose of this extended deployment was to participate in Network for the Detection of Atmospheric Composition Change (NDACC) Validation campaigns with the JPL Stratospheric Ozone Lidar and the NOAA Temperature, Aerosol and Water Vapor instruments as part of the routine NDACC Validation Protocol.

Lidar↗

The Ozone Water-Land Environmental Transition Study: An Innovative Strategy for Understanding Chesapeake Bay Pollution Events

Coastal regions have historically represented a significant challenge for air quality investigations because of water-land boundary transition characteristics and a paucity of measurements available over water. Prior studies have identified the formation of high levels of ozone over water bodies, such as the Chesapeake Bay, that can potentially recirculate back over land to significantly impact populated areas. Earth-observing satellites and forecast models face challenges in capturing the coastal transition zone where small-scale meteorological dynamics are complex and large changes in pollutants can occur on very short spatial and temporal scales. An observation strategy is presented to synchronously measure pollutants “over land” and “over water” to provide a more complete picture of chemical gradients across coastal boundaries for both the needs of state and local environmental management and new remote sensing platforms. Intensive vertical profile information from ozone lidar systems and ozonesondes, obtained at two main sites, one over land and the other over water, are complemented by remote sensing and in situ observations of air quality from ground-based, airborne (both personned and unpersonned), and shipborne platforms. These observations, coupled with reliable chemical transport simulations, such as the National Oceanic and Atmospheric Administration (NOAA) National Air Quality Forecast Capability (NAQFC), are expected to lead to a more fully characterized and complete land–water interaction observing system that can be used to assess future geostationary air quality instruments, such as the National Aeronautics and Space Administration (NASA) Tropospheric Emissions: Monitoring of Pollution (TEMPO), and current low-Earth-orbiting satellites, such as the European Space Agency’s Sentinel-5 Precursor (S5-P) with its Tropospheric Monitoring Instrument (TROPOMI).

Forecast Models↗

The Network for the Detection of Atmospheric Composition Change (NDACC): History, Status and Perspectives

The Network for the Detection of Atmospheric Composition Change (NDACC) is an international global network of more than 90 stations making high-quality measurements of atmospheric composition that began official operations in 1991 after 5 years of planning. Apart from sonde measurements, all measurements in the network are performed by ground-based remote-sensing techniques. Originally named the Network for the Detection of Stratospheric Change (NDSC), the name of the network was changed to NDACC in 2005 to better reflect the expanded scope of its measurements. The primary goal of NDACC is to establish long-term databases for detecting changes and trends in the chemical and physical state of the atmosphere (mesosphere, stratosphere, and troposphere) and to assess the coupling of such changes with climate and air quality. NDACC's origins, station locations, organizational structure, and data archiving are described. NDACC is structured around categories of ground-based observational techniques (sonde, lidar, microwave radiometers, Fourier-transform infrared, UV-visible DOAS (differential optical absorption spectroscopy)-type, and Dobson-Brewer spectrometers, as well as spectral UV radiometers), timely cross-cutting themes (ozone, water vapour, measurement strategies, cross-network data integration), satellite measurement systems, and theory and analyses. Participation in NDACC requires compliance with strict measurement and data protocols to ensure that the network data are of high and consistent quality. To widen its scope, NDACC has established formal collaborative agreements with eight other cooperating networks and Global Atmosphere Watch (GAW). A brief history is provided, major accomplishments of NDACC during its first 25 years of operation are reviewed, and a forward-looking perspective is presented.

lidar↗

Quantifying TOLNet Ozone Lidar Accuracy During the 2014 DISCOVER-AQ and FRAPPE Campaigns

The Tropospheric Ozone Lidar Network (TOLNet) is a unique network of lidar systems that measure high-resolution atmospheric profiles of ozone. The accurate characterization of these lidars is necessary to determine the uniformity of the network calibration. From July to August 2014, three lidars, the TROPospheric OZone (TROPOZ) lidar, the Tunable Optical Profiler for Aerosol and oZone (TOPAZ) lidar, and the Langley Mobile Ozone Lidar (LMOL), of TOLNet participated in the Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) mission and the Front Range Air Pollution and Photochemistry Experiment (FRAPPA) to measure ozone variations from the boundary layer to the top of the troposphere. This study presents the analysis of the intercomparison between the TROPOZ, TOPAZ, and LMOL lidars, along with comparisons between the lidars and other in situ ozone instruments including ozonesondes and a P-3B airborne chemiluminescence sensor. The TOLNet lidars measured vertical ozone structures with an accuracy generally better than +/-15 % within the troposphere. Larger differences occur at some individual altitudes in both the near-field and far-field range of the lidar systems, largely as expected. In terms of column average, the TOLNet lidars measured ozone with an accuracy better than +/-5 % for both the intercomparison between the lidars and between the lidars and other instruments. These results indicate that these three TOLNet lidars are suitable for use in air quality, satellite validation, and ozone modeling efforts.

TOLNet↗

Lidar Observations Revealing Transport of O3 in the Presence of a Nocturnal Low-Level Jet: Regional Implications for "Next-Day" Pollution

Remotely sensed profiles of ozone (O3) and wind are presented continuously for the first time during anocturnal low-level jet (NLLJ) event occurring after a severe O3 episode in the Baltimore-Washington D.C.(BW) urban corridor throughout 11-12 June 2015. High-resolution O3 lidar observations indicate a well mixedand polluted daytime O3 reservoir, which decayed into a contaminated nocturnal residual layer(RL) with concentrations between 70 and 100 ppbv near 1 km above the surface. Observations indicatethe onset of the NLLJ was responsible for transporting polluted O3 away from the region, while simultaneouslyaffecting the height and location of the nocturnal residual layer. High-resolution modelinganalyses and next-day (12 June) lidar, surface, and balloon-borne observations indicate the trajectory ofthe NLLJ and polluted residual layer corresponds with ''next-day'' high O3 at sites throughout thesouthern New England region (New York, Connecticut, Massachusetts). The novel O3 lidar observationsare evidence of both nocturnal advection (via high NLLJ wind fields) and entrainment of the pollutedresidual layer in the presence of the ''next-day'' convectively growing boundary layer. In the greatercontext, the novel observational suite described in this work has shown that the chemical budget in areasdownwind of major urban centers can be altered significantly overnight during transport events such asthe NLLJ.

ozone↗

Evaluating A Priori Ozone Profile Information Used in TEMPO Tropospheric Ozone Retrievals

Ozone (O3) is a greenhouse gas and toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is primarily conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address these limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME, GOME-2, and OMI. This algorithm uses a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB) O3 climatology). It has been shown that satellite O3 retrievals are sensitive to a priori O3 profiles and covariance matrices. During this work we investigate the climatological data to be used in TEMPO algorithms (TB O3) and simulated data from the NASA GMAO Goddard Earth Observing System (GEOS-5) Forward Processing (FP) near-real-time (NRT) model products. These two data products will be evaluated with ground-based lidar data from the Tropospheric Ozone Lidar Network (TOLNet) at various locations of the US. This study evaluates the TB climatology, GEOS-5 climatology, and 3-hourly GEOS-5 data compared to lower tropospheric observations to demonstrate the accuracy of a priori information to potentially be used in TEMPO O3 algorithms. Here we present our initial analysis and the theoretical impact on TEMPO retrievals in the lower troposphere.

ozone↗

Quantifying the Contribution of Thermally Driven Recirculation to a High-Ozone Event Along the Colorado Front Range Using Lidar

A high-ozone (O3) pollution episode was observed on 22 July 2014 during the concurrent Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) and Front Range Air Pollution and Photochemistry Experiment (FRAPPE) campaigns in northern Colorado. Surface O3 monitors at three regulatory sites exceeded the Environmental Protection Agency (EPA) 2008 National Ambient Air Quality Standard (NAAQS) daily maximum 8h average (MDA8) of 75ppbv. To further characterize the polluted air mass and assess transport throughout the event, measurements are presented from O3 and wind profilers, O3-sondes, aircraft, and surface-monitoring sites. Observations indicate that thermally driven upslope flow was established throughout the Colorado Front Range during the pollution episode. As the thermally driven flow persisted throughout the day, O3 concentrations increased and affected high-elevation Rocky Mountain sites. These observations, coupled with modeling analyses, demonstrate a westerly return flow of polluted air aloft, indicating that the mountain-plains solenoid circulation was established and impacted surface conditions within the Front Range.

Front Range Air Pollution and Photochemistry Exper↗

Results of a Longer Term NDACC Measurements Comparison Campaign at Mauna Loa Observatory

Between November, 2015 and January, 2015, the Goddard Space Flight Center (GSFC) operated a pair of lidar instruments at the NOAA (National Oceanic and Atmospheric Administration) facility at Mauna Loa on the Big Island of Hawaii (Latitude 19.5 degrees North, Longitude 155.5 degrees West, altitude 3.397 kilometers). Measurements were made during six different four week periods during this time period by both the NASA GSFC Stratospheric Ozone Lidar (STROZ) and the Aerosol and Temperature (ATL) lidar. Also making measurements were the JPL Stratospheric Ozone Lidar and the NOAA Aerosol and Water Vapor Lidar. All instruments participate and archive data with the Network for the Detection of Atmospheric Composition Change (NDACC). Measurement comparisons were made among various instruments in accordance with the standard intercomparison protocols of the NDACC.

McGee, Thomas J.↗

Ozone Lidar Observations for Air Quality Studies

Tropospheric ozone lidars are well suited to measuring the high spatio-temporal variability of this important trace gas. Furthermore, lidar measurements in conjunction with balloon soundings, aircraft, and satellite observations provide substantial information about a variety of atmospheric chemical and physical processes. Examples of processes elucidated by ozone-lidar measurements are presented, and modeling studies using WRF-Chem, RAQMS, and DALES/LES models illustrate our current understanding and shortcomings of these processes.

Ozone↗

Characterizing the Vertical Processes of Ozone in Colorado's Front Range Using the GSFC Ozone Dial

Although characterizing the interactions of ozone throughout the entire troposphere are important for health and climate processes, there is a lack of routine measurements of vertical profiles within the United States. In order to monitor this lower ozone more effectively, the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center TROPospheric OZone DIfferential Absorption Lidar (GSFC TROPOZDIAL) has been developed and validated within the Tropospheric Ozone Lidar Network (TOLNet). Two scientifically interesting ozone episodes are presented that were observed during the 2014 Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER AQ) campaign at Ft. Collins,Colorado.The first case study, occurring between 22-23 July 2014, indicates enhanced concentrations of ozone at Ft. Collins during nighttime hours, which was due to the complex recirculation of ozone within the foothills of the Rocky Mountain region. Although quantifying the ozone increase a loft during recirculation episodes has been historically difficult, results indicate that an increase of 20 -30 ppbv of ozone at the Ft. Collins site has been attributed to this recirculation. The second case, occurring between Aug 4-8th 2014, characterizes a dynamical exchange of ozone between the stratosphere and the troposphere. This case, along with seasonal model parameters from previous years, is used to estimate the stratospheric contribution to the Rocky Mountain region. Results suggest that a large amount of stratospheric air is residing in the troposphere in the summertime near Ft. Collins, CO. The results also indicate that warmer tropopauses are correlated with an increase in stratospheric air below the tropopause in the Rocky Mountain Region.

Sullivan, John T.↗

AROTAL Ozone and Temperature Vertical Profile Measurements from the NASA DC-8 during the SOLVE II Campaign

The AROTAL instrument (Airborne Raman Ozone Temperature and Aerosol Lidar) - a collaboration between scientists at NASA Goddard Space Flight Center, and Langley Research Center - was flown on the NASA DC-8 during the SOLVE II Campaign during January and February, 2003. The flights were flown from the Arena Arctica in Kiruna, Sweden. We report measurements of temperature and ozone profiles showing approximately a 600 ppbv loss in ozone near 17.5 km, over the time frame of the aircraft campaign. Comparisons of ozone profiles from AROTAL are made with the SAGE III instrument.

McGee, Thomas J.↗

Mobile Lidar Operations at GSFC

Since the last meeting, the GSFC Stratospheric Ozone Lidar has participated in two campaigns at MLO - an ozone and temperature comparison and a water vapor comparison. The trailer has been returned to GSFC to begin transfer into a sea container, before deployment to Reunion Island in Spring, 2004.

McGee, Thomas J.↗

An Assessment of the Ozone Loss During the 1999-2000 SOLVE Arctic Campaign

Ozone observations from ozonesondes, the lidars aboard the DC-8, in situ ozone measurements from the ER-2, and satellite ozone measurements from Polar Ozone and Aerosol Measurement III (POAM) were used to assess ozone loss during the Sage III Ozone Loss and Validation Experiment (SOLVE) 1999-2000 Arctic campaign. Two methods of analysis were used. In the first method a simple regression analysis is performed on the ozonesonde and POAM measurements within the vortex. In the second method, the ozone measurements from all available ozone data were injected into a free running diabatic trajectory model and carried forward in time from December 1 to March 15. Vortex ozone loss was then estimated by comparing the ozone values of those parcels initiated early in the campaign with those parcels injected later in the campaign. Despite the variety of observational techniques used during SOLVE, the measurements provide a fairly consistent picture. Over the whole vortex, the largest ozone loss occurs between 550 and 400 K potential temperatures (approximately 23-16 km) with over 1.5 ppmv lost by March 15, the end of the SOLVE mission period. An ozone loss rate of 0.04-0.05 ppmv/day was computed for March 15. Ozonesondes launched after March 15 suggest that an additional 0.5 ppmv or more ozone was lost between March 15 and April 1. The small disagreement between ozonesonde and POAM analysis of January ozone loss is found to be due to biases in vortex sampling. POAM makes most of its solar occultation measurements at the vortex edge during January 2000 which bias samples toward air parcels that have been exposed to sunlight and likely do experience ozone loss. Ozonesonde measurements and the trajectory technique use observations that are more distributed within the interior of the vortex. Thus the regression analysis of the POAM measurements tends to overestimate mid-winter vortex ozone loss. Finally, our loss calculations are broadly consistent with other loss computations using ER-2 tracer data and MLS satellite data, but we find no evidence for the 1992 high mid-January loss reported using the Match technique.

Schoeberl, Mark R.↗

Retrieval of Polar Stratospheric Cloud Microphysical Properties From Lidar Measurements: Dependence on Particle Shape Assumptions

Knowledge of particle sizes and number densities of polar stratospheric clouds (PSCs) is highly important, because they are critical parameters for the modeling of the ozone chemistry of the stratosphere. In situ measurements of PSC particles are rare. the main instrument for the accumulation of PSC data are lidar systems. Therefore the derivation of some microphysical properties of PSCS from the optical parameters measured by lidars would be highly beneficial for ozone research. Inversion of lidar data obtained in the presence of PSCs formed from crystalline particles type 11 and the various nitric acid tri Ydrrate (NAT) types cannot be easily accomplished, because a suitable scattering theory for small faceted crystals has not been readily available tip to now. As a consequence, the T-matrix method is commonly used for the interpretation of these PSC lidar data. Here the assumption is made that the optical properties of an ensemble of spheroids resemble those of crystalline PSCs, and microphysical properties of the PSC are inferred from the optical signatures of the PSC at two or more wavelengths. The problem with the T-matrix approach is that the assumption of spheroidal instead of faceted particles can lead to dramatically wrong results: Usually cloud particle properties are deduced from analysis of lidar profiles of backscatter ratio and depolarization ratio. The particle contribution to the backscatter ratio is given by the product of the particle number density and the backscattering cross section. The latter is proportional to the value of the particle's scattering phase function at 180 degrees scattering angle. At 180 degrees however, the phase functions of rough, faceted crystals and of spheroids with same maximum dimension differ by a factor of 6. From this it follows that for a PSC consisting of faceted crystals, the particle number density is underestimated by roughly the same factor if spheroidal particles are unrealistically assumed. We are currently developing a retrieval technique for determining the microphysical parameters of crystalline PSCs that takes into account the faceted shape of the PSC particles. This approach utilizes finite-difference time-domain (FDTD) calculations of particle optical properties. The accuracy and the free choice of the shape of the scattering particle make the FDTD technique a promising tool for the inversion of PSC lidar data. A first comparison of FDTD and T-matrix calculations will be presented.

Reichardt, Susanne↗

Microphysical Interpretation of Cirrus Measurements With Lidar

Cirrus measurements obtained with a ground-based polarization Raman lidar at 67.9 N in January 1997 reveal a strong correlation between the particle optical properties, specifically depolarization ratio delta and extinct ion-to-backscatter ratio S, for ambient cloud temperatures above approximately -45 C (delta less than approximately 40%), and an anti-correlation for colder temperatures (delta greater than approximately 40%). Over the length of the measurements (4-7.5 hours) the particle properties vary systematically: Initially, delta approximately equal to 60% and S approximately equal to 10sr are observed. Then, with decreasing delta, S first increases to approximately 27 sr(delta approximately equal to 40%) before decreasing to values around 10 sr again (delta approximately equal to 20%). The particle optical properties distinctly depend on the ambient temperature. For the microphysical analysis of the lidar observations. ray-tracing computations of particle scattering properties and a size-distribution resolving cirrus model with explicit microphysics have been used. The theoretical studies show that the optical properties and their temporal evolution can be interpreted in terms of size, shape, and growth of the cirrus particles: Near the cloud top in the early stage of the cirrus development, light scattering by small hexagonal columns with aspect ratios close to one is dominant. Over time the cloud base height extends to lower altitudes with warmer temperatures, the ice particles grow and get morphologically diverse (the scattering contributions of hexagonal columns and plates are roughly the same for large S and depolarization values of approximately 40%). In the lower ranges of the cirrus clouds, light scattering is predominantly by plate-like or complex ice particles. Mid-latitude cirrus data measured with the same instrument at 53.4 N between 1994 and 1996 follow closely the correlation between delta and S found in the warmer regions of the Arctic cirrus clouds (delta less than approximately 40%). Cirrus clouds with higher depolarization ratios are rarely observed, even for very cold ambient temperatures. Atmospheric parameters other than temperature, e.g., the availability of water vapor, are also important for the growth and the morphology of cirrus particles.

Reichardt, Jens↗

A Comparison of Co-located Ozonesonde and Lidar Measurements

As part of the NDSC, the GSFC mobile Ozone Lidar instrument has participated in numerous validation campaigns around the world. During all of these campaigns, ozonesondes were flown as part of the intercomparisons. This poster summarizes the results of these campaigns, and indicates that there are some biases between the sonde and lidar measurements.

McGee, Thomas J.↗

An Intercomparison of Lidar Ozone and Temperature Measurements From the SOLVE Mission With Predicted Model Values

Temperature profiles acquired by Goddard Space Flight Center's AROTEL lidar during the SOLVE mission onboard NASA's DC-8 are compared with predicted values from several atmospheric models (DAO, NCEP and UKMO). The variability in the differences between measured and calculated temperature fields was approximately 5 K. Retrieved temperatures within the polar vortex showed large regions that were significantly colder than predicted by the atmospheric models.

Burris, John↗