Engineering Papers⌕ Search

Engineering topics

McGee, T.

Publications and source records attributed to McGee, T..

Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofısica de Andalucıa (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

MIPAS validation↗

Lidar Measurements of Stratospheric Ozone, Aerosols and Temperature during the SAUNA Campaign at Sodankyla, Finland

The Sodankyla Total Column Ozone Intercomparison (SAUNA) campaign took place at the Finnish Meteorological Institute Arctic Research Center (FMI-ARC) at Sodankyla, Finland (67.37 N) in two separate phases during early spring 2006, and winter 2007. These campaigns has several goals: to determine and improve the accuracy of total column ozone measurements during periods of low solar zenith angle and high total column ozone; to determine the effect of ozone profile shape on the total column retrieval; and to make validate satellite ozone measurements under these same conditions. The GSFC Stratospheric Ozone Lidar (STROZ), which makes profile measurements of ozone temperature, aerosols and water vapor participated in both phases of the campaign. During the deployments, more than 30 profile measurements were made by the lidar instrument, along with Dobson, Brewer, DOAS, ozonesonde, and satellite measurements. The presentation will concentrate on STROZ lidar results from the second phase of the campaign and comparisons with other instruments will be discussed. This will include both ground-based and satellite comparisons.

McGee, T.↗

The Water Vapor Variability - Satellite/Sondes (WAVES) Field Campaigns

Three NASA-funded field campaigns have been hosted at the Howard University Research Campus in Beltsville, MD. In each of the years 2006, 2007 and 2008, WAVES field campaigns have coordinated ozonesonde launches, lidar operations and other measurements with A-train satellite overpasses for the purposes of satellite validation. The unique mix of measurement systems, physical location and the interagency, international group of researchers and students has permitted other objectives, such as mesoscale meteorological studies, to be addressed as well. We review the goals and accomplishments of the three WAVES missions with the emphasis on the nonsatellite validation component of WAVES, as the satellite validation activities have been reported elsewhere.

Whiteman, D. N.↗

SAUNA Ozone Profile Comparison: SBUV/2 and MLS versus Sondes and Lidar

The Sodankyla Total Column Ozone Intercomparison (SAUNA) was held in Sodankyla, Finland in March-April 2006 and February-March 2007 in support of Aura validation. The purpose of SAUNA was to assess the comparative performance of the ground-based instruments and algorithms when measuring total column ozone at large solar zenith angles and high total column ozone amounts. Results showed that the ozone profiles from the satellite instruments (MLS on Aura and SBUV/2 on NOAA 16) generally agreed with profiles from the ground-based instruments (lidar and sondes) within 10%. The largest differences were seen in the profile below 20 km, consistent with our conclusion that spatial variability in the lower stratosphere and upper troposphere is a significant source of disagreement in these comparisons. The total column ozone comparison shows that SBUV/2 and OMI agree well with the double Brewer instruments provided the scenes are carefully matched.

McPeters, R. D.↗

Non-coincident Inter-instrument Comparisons of Ozone Measurements Using Quasi-conservative Coordinates

Ozone measurements from ozonesondes, AROTAL, DIAL, and POAM III instruments during the SOLVE-2/VINTERSOL period are composited in a time-varying, flow-following quasi-conservative (PV-6) coordinate space; the resulting composites from each instrument are mapped onto the other instruments locations and times. The mapped data are then used to intercompare data from the different instruments. Overall, the four data sets are found to be in good agreement. AROTAL shows somewhat lower values below 16 km, and DIAL has a positive bias at the upper limits of its altitude range. These intercomparisons are consistent with those obtained from more conventional near-coincident profiles, where available. Although the PV-theta mapping technique entails larger uncertainties of individual profile differences compared to direct near-coincident comparisons, the ability to include much larger numbers of comparisons can make this technique advantageous.

Lait, L. R.↗

Vapor Measurements from the GSFC Stratospheric Ozone Lidar

Water vapor measurements from the GSFC Stratospheric Ozone Lidar were made for the first time during a campaign at NOAA's Mauna Loa Observatory. Comparisons were made among the GSFC lidar, the NOAA Lidar and water vapor sondes which were flown from the observatory at times coincident with the lidar measurements.

McGee, T.↗

Ozone Loss From Quasi-Conservative Coordinate Mapping During the 1999-2000 SOLVE Campaign

During the winter of 1999-2000, the Sage III Ozone Loss and Validation Experiment (SOLVE) field experiment took place in Kiruna, Sweden. The purpose of SOLVE was to examine ozone depletion mechanisms in the Arctic stratosphere (from about 10 to 50 km altitude) during the winter and early spring, when a band of strong winds (the 'polar vortex') circle the pole. Measurements of stratospheric ozone were made by several different kinds of instruments in different meteorological situations. We analyzed these data using the 'quasi-conservative coordinate mapping' technique, in which the measurements are analyzed in terms of meteorological properties ('potential temperature' and 'potential vorticity') which tend not to change very much over a few days. This technique reduces or removes the changes that are associated with the polar vortex moving around. Over longer time periods, potential temperature and potential vorticity change as air cools and descends within the polar vortex. We account for these changes by calculating the trajectories of air parcels, and this enables us to extend the analysis over a ten-week period from January 10 to March 17, 2000. Using data from the NASA ER-2 aircraft, from the DIAL and AROTEL laser sounders on the NASA DC-8 aircraft, and balloon-borne ozonesondes, our analysis reveals changes in ozone which, because we have removed the effects of polar vortex motion and the descending air, indicate chemical destruction of ozone in early 2000. We find a peak decline rate of approximately 0.03 ppmv/day near 470 K of potential temperature (near 20 km) in mid-January which sinks in altitude to around 440 K (near 18 km) in mid-March.

Lait, L. R.↗

An Assessment of the Ozone Loss During the 1999-2000 SOLVE Campaign

Ozone observations from ozonesondes, the DIAL and AROTEL lidars aboard the DC-8, in situ ozone measurements from the ER-2 and satellite ozone measurements from POAM were used to assess ozone loss during the SOLVE 1999-2000 campaign. We compare three different methods of computing the ozone loss. The first method simply compares the time sequence of ozonesondes taken at the same station inside the vortex from December through the end of March. In the second method, ozonesondes from a variety of stations are compared using a variant on the Match technique. This method uses short (approx. 5-10 day) forward diabatic trajectories to connect various sonde launches. In the third method, the measurements are simply injected into a diabatic trajectory model and carried forward in time from December 1 to March 16. Over 60,000 individual measurements were used in the last calculation. Again, ozone loss is estimated by comparing vortex interior measurements made early in the campaign with those made later in the campaign. The diabatic nature of the second and third methods calculation presumably corrects for the normal increase in ozone within the vortex due to downward advection. The three methods agree that the largest ozone loss occurs between 400 and 460 K potential temperatures (approx. 16-20 km) with slightly over 1.5 ppmv lost over the winter period. Between 460 K and 500 K (approx. 22 km) net ozone loss is less than 0.8 ppmv. From 500K to 600K (26 km) net loss is less than 0.5 ppmv.

Schoeberl, M. R.↗

Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)

In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.

McPeters, R. D.↗

Results of the NY-Alesund ozone measurements intercomparison NAOMI

Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

Steinbrecht, W.↗

Low gravity transfer line chilldown

A code has been developed that solves for the transfer line chilldown time and flow and heat transfer characteristics in one-g environment. The code solves the transient, one dimensional, space averaged mass, momentum and energy conservation equations for liquid-vapor two-phase flow in tubes. The physical configuration solved is that appropriate for bottom coolant injection in a vertically supported heated tube. Four distinct regions are considered consecutively: fully liquid. inverted annular. dispersed and fully vapor flow. The conservation equations for both the liquid and the vapor are solved in each region separately. Also, in each region the mass and energy transport between each phase as well as the energy and momentum transport between the tube wall and the fluid are accounted for. A finite wall thickness is also considered.

Antar, B. N.↗