Engineering Papers⌕ Search

Engineering topics

McFarlane, Nicole

Publications and source records attributed to McFarlane, Nicole.

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗