Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗

The DD Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Uranium Neutron Coincidence Collar

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques because of the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Coincidence Collar (UNCL), and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every 5–7 years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. Previously we examined the performance of Oak Ridge National Laboratory’s Large Volume Active Well Coincidence Counter modified to accept a commercially available deuterium-deuterium (DD) neutron generator to examine the potential of the DD neutron generator as an alternative to the isotopic sources [1]. That work indicated that the DD generator was a viable replacement for the AWCC applications, but because of the large dimensions of that generator, the DD/AWCC would have to be run as a delayed neutron counting system to provide equivalent measurement precision. In this work we examine the performance of a standard UNCL modified to accept the DD neutron generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium and highly enriched uranium items. The projected performance of the modified UNCL for fresh pressurized water reactor fuel assemblies operated in both traditional coincidence counting and delayed neutron counting modes is presented.

07 ISOTOPE AND RADIATION SOURCES↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DN/DG Screening of Environmental Swipe Samples: FY2016 Report

The Delayed Neutron Delayed Gamma (DNDG) technique provides a new analytical capability to the International Atomic Energy Agency (IAEA) for detecting undeclared nuclear activities. IAEA’s Long Term R&D (LTRD) plan has a stated high urgency need to develop elemental and isotopic signatures of nuclear fuel cycle activities and processes (LTRD 2.2). The new DNDG capability is used to co-detect both uranium and plutonium as an extension of a DN only method that is already being utilized by the IAEA for the analysis of swipes to inform on undeclared nuclear activities. Analytical method involving irradiation of swipe samples potentially containing trace quantities of fissile material in a thermal neutron field, followed by the counting of delayed neutrons, is a well-known technique in the field of safeguards and nonproliferation. It is used for detecting the presence of microscopic amounts of fissile material, (typically a linear combination of 233 U, 235 U, 239 Pu, and 241 Pu)and quantifying it in terms of the equivalent mass of 235U. The delayed neutron (DN) technique is very sensitive and is been routinely employed at the High Flux Isotope Reactor (HFIR) facility at Oak Ridge National Laboratory (ORNL). Both uranium and plutonium are of high safeguards value. However, the DN technique is not well suited for distinguishing between U and Pu isotopes since the decay curves overlap closely. The delayed gamma (DG) technique will help detect the presence of 239Pu in a mixture of U and Pu. Thus the DNDG approach combines the best of both worlds; the sensitivity of DN counting and the isotopic specificity of DG counting. The present work seeks to build on the delayed neutron and delayed gamma methods that have been developed at ORNL. It is recognized that the distribution profile of heavy fission products remains fairly invariant for the fissile nuclides whereas the distribution of light fission products varies from one isotope to another. That is, the ratio of the yield of a light fission fragment to a heavy fission fragments is isotope specific. Measurement of the ratio of the net full energy peak (FEP) from low/high mass fission products is an elegant way to characterize the fraction of fissile materials present in a mixture. By empirically calibrating the ratio of the net FEP as a function of known concentration of the binary mixture, one can determine the fraction of fissile isotopes in an unknown sample. In the work done in fiscal year (FY) 2016, samples of single fissile material isotopes as well as binary mixtures were irradiated in a well thermalized irradiation field in the HFIR. Delayed neutron counting was performed using the neutron counter at the HFIR Neutron Activation Analysis (NAA) laboratory. Delayed gamma counting was performed using a shielded high purity germanium (HPGe) detector. Delayed neutron decay curve results highlighted the difficulty of distinguishing between U and Pu isotopes, and the need for including the delayed gamma component. Based on delayed gamma spectrometry, twelve ratios of low mass/high fission product gamma ray FEP have been identified as valid candidates. Linearity of the ratios, as a function of 239 Pu fraction in 235 U+ 239 Pu mixtures, was confirmed for the low mass/high mass candidates that were selected. The DNDG method we are spearheading allows not only the presence of total fissile content to be detected, but whether the material is predominantly U or predominantly Pu, or a mixture. This provides additional SG relevant information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation of Spectroscopic Detectors for LEU Hold-up Measurements

The hold-up measurement of low-enriched uranium materials may require use of alternate detector types relative to the measurement of highly enriched uranium. This is in part due to the difference in process scale (i.e., the components are generally larger for low-enriched uranium systems), but also because the characteristic gamma-ray lines from 235 U used for assay of highly enriched uranium will be present at a much reduced intensity (on a per gram of uranium basis) at lower enrichments. Researchers at Oak Ridge National Laboratory examined the performance of several standard detector types, e.g., NaI(Tl), LaBr3(Ce), and HPGe, to select a suitable candidate for measuring and quantifying low-enriched uranium hold-up in process pipes and equipment at the Portsmouth gaseous diffusion plant. Detector characteristics, such as energy resolution (full width at half maximum) and net peak count rates at gamma ray energies spanning a range of 60–1332 keV, were measured for the above-mentioned detector types using the same sources and in the same geometry. Uranium enrichment standards (Certified Reference Material no. 969 and Certified Reference Material no. 146) were measured using each of the detector candidates in the same geometry. The net count rates recorded by each detector at 186 keV and 1,001 keV were plotted as a function of enrichment (atom percentage). Background measurements were made in unshielded and shielded configurations under both ambient and elevated conditions of 238 U activity. The highly enriched uranium hold-up measurement campaign at the Portsmouth plant was performed on process equipment that had been cleaned out. Therefore, in most cases, the thickness of the uranium deposits was less than the “infinite thickness” for the 186 keV gamma rays to be completely self-attenuated. Because of this, in addition to measuring the 186 keV gamma, the 1,001 keV gamma ray from 234m Pa—a daughter of 238 U in secular equilibrium with its parent—will also need to be measured. Based on the performance criteria of detection efficiency, energy resolution, peak-to-continuum ratios, minimum detectable limits, and the weight of the shielded probe, a shielded (0.5 in. thick lead shield) 2 × 2 in. NaI(Tl) detector is recommended for use. The recommended approach is to carry out analysis using data from both 186 keV and 1,001 keV gamma rays, and select a best result based on propagated uncertainty estimates. It is also highly recommended that a two-point gain stabilization scheme based on an 241 Am seed embedded in the probe be implemented. Shielding configurations to reduce the impact of background interference on the measurement of 1,001 keV gamma-ray are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel

The potential performance of a notional active coincidence collar for assaying uranium fuel based on segmented detectors constructed from the new PSD plastic fast organic scintillator with pulse shape discrimination capability was investigated in simulation. Like the International Atomic Energy Agency's present Uranium Neutron Collar for LEU (UNCL), the PSD plastic collar would also function by stimulating fission in the 235 U content of the fuel with a moderated 241 Am/Li neutron source and detecting instances of induced fission via neutron coincidence counting. In contrast to the moderated detectors of the UNCL, the fast time scale of detection in the scintillator eliminates statistical errors due to accidental coincidences that limit the performance of the UNCL. However, the potential to detect a single neutron multiple times historically has been one of the properties of organic scintillator detectors that has prevented their adoption for international safeguards applications. Consequently, as part of the analysis of simulated data, a method was developed by which true neutron-neutron coincidences can be distinguished from inter-detector scatter that takes advantage of the position and timing resolution of segmented detectors. Then, the performance of the notional simulated coincidence collar was evaluated for assaying a variety of fresh fuels, including some containing burnable poisons and partial defects. In these simulations, particular attention was paid to the analysis of fast mode measurements. In fast mode, a Cd liner is placed inside the collar to shield the fuel from the interrogating source and detector moderators, thereby eliminating the thermal neutron flux that is most sensitive to the presence of burnable poisons that are ubiquitous in modern nuclear fuels. The simulations indicate that the predicted precision of fast mode measurements is similar to what can be achieved by the present UNCL in thermal mode. For example, the statistical accuracy of a ten-minute measurement of fission coincidences collected in fast mode will be approximately 1% for most fuels of interest, yielding a ~1.4% error after subtraction of a five minute measurement of the spontaneous fissions from 238 U in the fuel, a ~2% error in analyzed linear density after accounting for the slope of the calibration curve, and a ~2.9% total error after addition of an assumed systematic error of 2%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance evaluation of the ORNL multi-elemental XRF analysis algorithms

Hybrid K-Edge Densitometer (HKED) systems integrate both K-Edge Densitometry (KED) and X-Ray Fluorescence (XRF) analyses to provide accurate rapid, assay results of the uranium and plutonium content of dissolver solution samples from nuclear fuel reprocessing facilities. Introduced for international safeguards applications in the late 1980s, the XRF component of the hybrid analyses is limited to quantification of U and Pu over a narrow range of U:Pu concentration ratios in the vicinity of ≈100. The analysis was further limited regarding the presence of minor actinide components where only a single minor actinide (typically Am) is included in the analysis and then only treated as an interference. The evolving nuclear fuel cycle has created the need to assay more complex dissolver solutions where uranium may no longer be the dominant actinide in the solution and the concentrations of the so called minor actinides (e.g., Th, Np, Am, and Cm) are sufficiently high that they can no longer be treated as impurities and ignored. Extension of the traditional HKED Region of Interest (ROI) based analysis to include these additional actinides is not possible due to the increased complexity of the XRF spectra. Oak Ridge National Laboratory (ORNL) has developed a spectral fitting approach to the HKED XRF measurement with an enhanced algorithm set to accommodate these complex XRF spectra. This report provides a summary of the spectral fitting methodology and examines the performance of these algorithms using data obtained from the ORNL HKED system, as well as data provided by the International Atomic Energy Agency (IAEA) on actual dissolver solutions.

97 MATHEMATICS AND COMPUTING↗

Comparison of Hybrid K-Edge Densitometer (HKED) Performance Operating with the Canberra Lynx MCA and the Canberra ICB-NIM Electronics

From the 1991 until 2008 the Canberra Hybrid K-Edge Densitometer systems were provided with ICB-NIM (Integrated Control Bus – Nuclear Instrument Module) acquisition electronics. Newer electronics modules, such as the Lynx, were not supported under the VMS based operating system. The LYNX module was provided as the standard acquisition electronics following the release of the Windows based CHKED software. This report compares the electronics dead-time, gain shifts, detector resolution and measurement performance of the HKED system operated with the two types of acquisition modules. The comparison was performed using measurements obtained with the ORNL HKED system. The original intent of this study was to take advantage of both the timing and energy outputs from the HPGE detector to acquire data with both sets of electronics in parallel. Although this approach has been applied successfully with other systems, in this case we found the timing output produced a significant amount of noise such that a comparison between the electronics would be invalid. So the comparative measurements were performed sequentially. The ICB-NIM data was acquired over the course of 12 months with 255 measurements while the LYNX data was acquired over a period of 10 months with 75 measurements. To simplify the comparison, all data used in this study was acquired using the Canberra CHKED (V1.0) software package. The performance analysis was based primarily on the peak locations, peak widths and concentration values reported by the CHKED software. The raw spectra from the XRF measurements were also examined to extract additional 109Cd peak location and width data for the hybrid measurements (the standard hybrid report template does not report these values).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Energy Approach for Neutron Interrogation of Uranium Items

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the high penetrability of neutrons, providing the ability to quickly and accurately measure effective uranium masses in large, dense configurations. These active techniques employ an external neutron source to induce fission in the uranium and subsequently measure emitted prompt fission or delayed neutrons. Unfortunately, the emitted neutrons from 235U and 238U are, for all practical purposes, indistinguishable; therefore, common systems such as the Active Well Coincidence Counter and other systems based on measurement of prompt or delayed fission neutrons require many representative calibration standards or known isotopic information to interpret the results, thus limiting the application of these techniques for safeguards purposes. This paper presents the motivation for a multi-energy neutron interrogation technique which aims to improve the accuracy of these NDA techniques through the use of multiple neutron interrogation sources. Potentially, the dual measurement approach will allow the mass values of the isotopes in the item to be independently determined while minimizing the number of representative standards needed and/or eliminating the need for prior knowledge of the isotopic information. This work examines the change in fission rates with differing interrogating neutron energy and, therefore, the potential of this new technique to independently measure the masses of 235U and 238U in the measurement item. Initial simulation and measurement results will be presented.

Hayward, Jason P.↗

3 He Alternatives Summary Report

Most of the 3 He consumed by neutron-based safeguards assay systems is used in neutron coincidence and neutron multiplicity counting systems. Detection methods for the limited number of total neutron counting applications are not considered in this report, but it is believed that the boron-lined tubes [1, 2] already developed for portal monitoring applications will serve as a suitable replacement for those measurements. In this report, we discuss the potential replacement technologies that are most suitable for use in safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗