Optimizing Umkehr Ozone Profile Retrievals

NOAA Dobson Umkehr ozone profile records have been collected since the 1970s. Umkehr ozone profiles are used to monitor stratospheric ozone recovery predicted to occur by the 2050s. Current operational Dobson Umkehr profile algorithms produce data that have uncertainty on the order of ~ 5 % in the stratosphere. However, when large volcanic eruptions inject aerosols into the stratosphere, the errors can be as large as 70 %. In order to evaluate Umkehr records for aerosol-related and instrumental artifacts, we compare observations with a Hindcast simulation of the NASA Merra-2 Global Modeling Initiative (GMI) Replay (M2GMI, Orbe et al, 2017; Wargan et al, 2018) and Chemistry Transport Model (GMI CTM, Strahan et al, 2013, Strahan et al, 2016). The biases found between the models and observations are summarized for each Dobson calibration and volcanic eruption period, thus providing a reference tool for homogenization of the Umkehr time series and removal of volcanic aerosol errors.

Petropavlovskikh, I.↗

Comparison of Ozone Retrievals from the Pandora Spectrometer System and Dobson Spectrophotometer in Boulder, Colorado

A comparison of retrieved total column ozone (TCO) amounts between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado, NOAA building. This paper, part of an ongoing study, covers a 1-year period starting on 17 December 2013. Both the standard Dobson and Pandora TCO retrievals required a correction, TCO(sub corr) = TCO (1 + C(T)), using a monthly varying effective ozone temperature, T(sub E), derived from a temperature and ozone profile climatology. The correction is used to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T(sub E)) are C(sub Pandora) = 0.00333(T(sub E) - 225) and C(sub Dobson) = -0.0013(T(sub E) - 226.7) per degree K. After the applied corrections removed most of the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r(exp 2) = 0.97 and an average offset of 1.1 +/- 5.8 DU. In addition, the Pandora TCO data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).

Herman, J.↗