Engineering Papers⌕ Search

Engineering topics

Mayer, Tyler

Publications and source records attributed to Mayer, Tyler.

Advanced Data Structures for Improved Cyber Resilience and Awareness in Untrusted Environments: LDRD Report

This report summarizes the work performed under the project "Advanced Data Structures for Improved Cyber Resilience and Awareness in Untrusted Environments." The goal of the project was to design, analyze, and test new data structures for cybersecurity applications. We had two major thrusts: 1) using new/improved write-optimized data structures and/or algorithms to better man- age and analyze high-speed massive-volume cyberstreams, and 2) adding security features to data structures at minimum cost. Write optimization allows data structures to better use secondary memory to store and search a larger amount of useful information. Secondary memory is large compared to main memory, but data movement to and from secondary memory must be carefully managed to run quickly enough to keep up with fast streams. The first thrust included managing cyberstreams in parallel, both multi-threaded and distributed, and improving the benchmarking infrastructure for testing new streaming data structures. We considered both (near) real-time discovery of particular patterns, and improved logging for improved forensics. We considered two kinds of security-feature problem. The first was high-performance history- independent external-memory data structures. These provide certain protections to data if a disk is stolen. We also prove some trade-offs between speed and security in this setting. The second data-security problem is more secure data look-up in secret-shared data bases. This report summarizes the project's major accomplishments, with the background to under- stand these accomplishments. It gathers the abstracts and references for the six refereed publications that have appeared as part of this work. We summarize several accomplishments that will be submitted for publication. We then archive one piece of partial work that is not likely to be published in the near future: validation of history-independent data structure implementations.

97 MATHEMATICS AND COMPUTING↗

Aquantis 2.5 MW Ocean Current Generation Device - Scaled Tank Test Design and Results

Aquantis 2.5 MW Ocean Current Generation Device, Tow Tank Dynamic Rig Structural Analysis Results. This is the detailed documentation for scaled device testing in a tow tank, including models, drawings, presentations, cost of energy analysis, and structural analysis. This dataset also includes specific information on drivetrain, roller bearing, blade fabrication, mooring, and rotor characteristics.

16 TIDAL AND WAVE POWER↗

Novel Low Cost, High Reliability Wind Turbine Drivetrain

Clipper Windpower, in collaboration with United Technologies Research Center, the National Renewable Energy Laboratory, and Hamilton Sundstrand Corporation, developed a low-cost, deflection-compliant, reliable, and serviceable chain drive speed increaser. This chain and sprocket drivetrain design offers significant breakthroughs in the areas of cost and serviceability and addresses the key challenges of current geared and direct-drive systems. The use of gearboxes has proven to be challenging; the large torques and bending loads associated with use in large multi-MW wind applications have generally limited demonstrated lifetime to 8-10 years. The large cost of gearbox replacement and the required use of large, expensive cranes can result in gearbox replacement costs on the order of $\$$1M, representing a significant impact to overall cost of energy (COE). Direct-drive machines eliminate the gearbox, thereby targeting increased reliability and reduced life-cycle cost. However, the slow rotational speeds require very large and costly generators, which also typically have an undesirable dependence on expensive rare-earth magnet materials and large structural penalties for precise air gap control. The cost of rare-earth materials has increased 20X in the last 8 years representing a key risk to ever realizing the promised cost of energy reductions from direct-drive generators. A common challenge to both geared and direct drive architectures is a limited ability to manage input shaft deflections. The proposed Clipper drivetrain is deflection-compliant, insulating later drivetrain stages and generators from off-axis loads. The system is modular, allowing for all key parts to be removed and replaced without the use of a high capacity crane. Finally, the technology modularity allows for scalability and many possible drivetrain topologies. These benefits enable reductions in drivetrain capital cost by 10.0%, levelized replacement and O&M costs by 26.7%, and overall cost of energy by 10.2%. This design was achieved by: (1) performing an extensive optimization study that deter-mined the preliminary cost for all practical chain drive topologies to ensure the most competitive configuration; (2) conducting detailed analysis of chain dynamics, contact stresses, and wear and efficiency characteristics over the chain's life to ensure accurate physics-based predictions of chain performance; and (3) developing a final product design, including reliability analysis, chain replacement procedures, and bearing and sprocket analysis. Definition of this final product configuration was used to develop refined cost of energy estimates. Finally, key system risks for the chain drive were defined and a comprehensive risk reduction plan was created for execution in Phase 2.

17 WIND ENERGY↗

Full Life Wind Turbine Gearbox Lubricating Fluids

Industrial gear box lubricants typically are hydrocarbon based mineral oils with considerable amounts of additives to overcome the lack of base fluid properties like wear protection, oxidation stability, load carrying capacity, low temperature solidification and drop of viscosity at higher temperatures. For today's wind turbine gearboxes, the requirements are more severe and synthetic hydrocarbon oils are used to improve on this, but all such hydrocarbon based lubricants require significant amounts of Extreme Pressure (EP) additives to meet performance requirements. Perfluoropolyether (PFPE) fluids provide load carrying capacity as an inherent property. During the course of the project with the main tasks of 'Establish a Benchmark', 'Lubricant Evaluation', 'Full Scale Gearbox Trial' and 'Economic Evaluation', the PAO Reference oil exhibited significant changes after laboratory gear testing, in service operation in the field and full scale gearbox trial. Four hydrocarbon base oils were selected for comparison in the benchmarking exercise and showed variation with respect to meeting the requirements for the laboratory micro-pitting tests, while the PFPE fluid exceeded the requirements even with the material taken after the full scale gear box trial. This is remarkable for a lubricant without EP additives. Laboratory bearing tests performed on the PFPE fluids before and after the full scale gear box trial showed the results met requirements for the industry standard. The PFPE fluid successfully completed the full scale gear box test program which included baseline and progressive staged load testing. The evaluation of gears showed no micro-pitting or objectionable wear. By the final stage, lubricant film thickness had been reduced to just 21% of its original value, this was by design and resulted in a lambda ratio of well below 1.

17 WIND ENERGY↗