Engineering Papers⌕ Search

Engineering topics

Mayer, Michael F.

Publications and source records attributed to Mayer, Michael F..

At least 19 records

Watchmen 3.3.0 Release Notes

This document describes the changes to Watchmen. This includes improvements to stability, search features, display of more detailed sample information and user access via authentication.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.3.0 User Guide: Revision 9

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Phase II testing of Xenon International on Mount Schauinsland, Germany

Station RN33 on Mount Schauinsland near Freiburg, Germany, is part of the International Monitoring System monitoring radioxenon in air ( 131m Xe, 133 Xe, 133m Xe, and 135 Xe) for verification of the Comprehensive Nuclear Test Ban Treaty. Here, we present data from phase II testing of a new system, Xenon International at RN33, July 14th, 2021 to Jan 22nd, 2022, together with SPALAX data from the same time period. Radioxenon could be detected in 473 of 719 samples, among them many multiple isotope detections. Activity concentrations of spiked and selected environmental samples were verified by laboratory reanalysis. Finally, the sensitivity of Xenon International for radioxenons is up to one order of magnitude better for the metastable isotopes than that of the SPALAX, with a shorter sampling duration of 6 h.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Watchmen v3.2.0 Release Notes

This document describes the changes to Watchmen. This includes improvements to stability, search features, display of more detailed sample information and user access via authentication.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 User Guide: Revision 8

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Method for calculating radon activity and radon rejection using a beta-gamma detector

Radon interferes with concentration measurements used by atmospheric radioxenon systems. We demonstrate a method to quantify the amount of radon that is present in the detectors, the impact of radon activity on the minimum-detectable-concentrations, and how to determine the needed radon rejection levels. An example calculation shows a radon rejection level of 10 5 is sufficient to limit impact on the detector sensitivity. We anticipate this method will give analysist a better understanding of radon present in their measurements and allow system designers to tailor their systems’ radon rejection better for its location.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Argon-39 from locations near historic underground nuclear explosions

Measurement of radioactive gas seepage from an underground nuclear explosion is one of the primary methods to confirm whether an event was nuclear in nature. Radioactive noble gas indicators that are commonly targeted by such measurements (e.g. 133Xe, 37Ar) have half-lives of 35 days or less. Argon-39, an activation product similar to 37Ar, is produced by the interaction between neutrons and potassium in the surrounding geology and has a half-life of 269 years. Measurements taken at three sites near three historic underground nuclear test locations at the Nevada National Security Site have all shown highly elevated levels of 39Ar in subsurface air decades after the test events. Elevated levels of 39Ar (30-50 times background) were also detected in atmospheric air collected roughly 30 cm above ground level near two of these sites, and outside the entrance of the one tunnel site. These measurements demonstrate that 39Ar has the potential to be a long-term signature of an underground nuclear event which can be reliably detected at the surface or in the shallow subsurface. This radionuclide detection of an underground nuclear event decades after the event takes place is in contrast to the commonly held assumption that detecting underground nuclear events via radionuclides at the surface needs to be done in a matter of months. Depending upon what further studies show about the robustness of this signature in a variety of geological settings, it may in fact be easy to detect underground nuclear events at the surface for a very long time post-detonation.

Johnson, Christine M.↗

Analysis methods for quantifying Xe-127 samples from the UNESE project

In the Underground Nuclear Explosions Signatures Experiment (UNESE) radioactive 37 Ar and 127 Xe were used as tracers in subsurface migration experiments. As part of the experiment, methods were developed to quantify 127 Xe via β-γ coincidence spectroscopy. Later examination of the results highlighted a weakness of this analysis method in samples with no 127 Xe present, so a reanalysis of samples was performed to identify those which were falsely identified as having 127 Xe present. Ongoing work to develop a new analysis method with targeted regions of interest is also described. Measurements were also performed to quantify the concentration of 127 Xe and 37 Ar which were injected as part of UNESE Phase 2. A best value for the concentration of 37 Ar and 127 Xe was determined and reported here for use in future analyses of the UNESE Phase 2 results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beta-Gamma Data Viewer v2.2.34 User's Manual

This document provides an overview, and procedures, for operating the beta-gamma data viewer for 7 regions of interest (7 ROI) data. The Beta-Gamma 7 ROI Data Viewer is a set of software tools that allow for viewing and analysis of IMS 2.0 Pulse Height Data (PHD) / Pulse Beta Gamma (PBG) files, state of health (SoH) files, and event log files. This is an upgrade from previous release of the tool that includes calibration tools.

97 MATHEMATICS AND COMPUTING↗

UNESE Phase 2: Injection and measurement of gaseous tracers at U-12p Tunnel

In June 2018 radioactive ( 37 Ar and 127 Xe) and stable (SF 6 ) tracers were injected into the chimney of the Disko Elm underground nuclear explosion, located in the U-12p tunnel complex. After the injection sampling was performed from locations within the tunnel, a borehole drilled from the surface, and from the surface of the mesa. Additionally, the 127 Xe activity within the chimney was continuously monitored for two months after the injection. While none of the injected radiotracers were detected in the monitoring borehole, elevated levels of 39 Ar (an activation product produced by underground nuclear explosions) were detected and quantified in each sample.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Migration of noble gas tracers at the site of an underground nuclear explosion at the Nevada National Security Site

As part of an underground gas migration study, two radioactive noble gases and two stable tracer gases were injected into a nuclear explosion test chimney and allowed to migrate naturally. Soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 meters) to deeper levels (~160 meters) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.

Johnson, Christine M.↗

Optimization of lithium-glass fibers with lithium depleted coating for neutron detection

Neutron-detecting scintillating glass uses 6 Li to capture thermal neutrons to produce an a and triton particle, which have $a$ range of 6 $µm$ and 36 $µm$, respectively. Captures on the surface of the glass can cause one of the particles to not deposit their energy in the glass causing the neutron to not be detected. This effect can be mitigated in lithium glass scintillators by coating lithium- glass fibers with lithium depleted scintillating glass. Thus, the scintillator’s efficiency will be increased. Results from this work show that a 20-60% increase in neutron efficiency depending on core size can be achieved with scintillating glass coatings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$\beta-\gamma$ Absolute Calibration (Rev. 1)

Identification of nuclear events rely on accurate measurement of radioxenon releases. Measurement of radioxenon relies on accurately knowing the detection efficiency for each isotope. Four xenon isotopes are of interest: 135 Xe, 133 Xe, 133 mXe, and 131 mXe. Each isotope has a unique signature; however, there is overlap between each signature. A series of ratio terms, called interference ratios, helps account for the challenges created by the overlap. The ratio and detection efficiency terms are all determined during the initial detector calibration. Additional spectra are needed for a complete calibration: the radon daughter 214 Pb/ 214 Bi, the detector background, and the 137 Cs quality control (QC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Silicon Beta Cell Design

Silicon detectors have the potential to significantly improve the sensitivity limits for radioxenon detection. While silicon has beneficial attributes like improved energy resolution and memory effect, the sensitivity improvements will not occur without a properly designed beta cell that utilizes silicon detectors. This report details the key parameters that have been incorporated into the design of a silicon beta cell. Parameters that have the potential to change as a prototype silicon beta cell is developed and during the future commercialization process are also discussed. The design of the silicon beta cell has focused primarily on simulations and analytical models to optimize the mechanical properties. Additionally, a team of experts provided guidance and potential alternatives for the silicon detectors and electronics fabrication. A conceptual design for a silicon beta cell was completed, with an emphasis on the modularity of the system. The modularity allows for any potential changes that may be of interest during the prototyping phase or future spiral development to be implemented with minimal impact on the complete system. The impact of the silicon based beta cell is discussed in the conclusions, along with potential next steps. Mechanical design drawings for the beta cell could be used to manufacture a prototype beta cell and are available in an appendix document.

36 MATERIALS SCIENCE↗

Development of a multidimensional gamma-spectrometer

A high-sensitivity multidimensional gamma-spectrometer is being developed within the shallow underground laboratory at Pacific Northwest National Laboratory (PNNL, USA). The system consists of two Broad Energy Germanium (BEGe) detectors, inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, with reductions in the cosmic background by 49.6% and Compton suppression of 6.5%. For selected radionuclides this provides an overall MDA improvement of 52.7%. Utilizing both detectors for simultaneous measurements of thermally irradiated highly enriched uranium (HEU) increased peak identification and reduced uncertainty by 27.6%. The design uses commercially off-the-shelf (COTS) components, for which the configuration is described, to provide a practical and powerful solution for low-level nuclear measurements.

Compton suppression↗