Engineering PapersSearch

Engineering topics

May, Randy D.

Publications and source records attributed to May, Randy D..

At least 19 records

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring

Five-Channel Infrared Laser Absorption Spectrometer for Combustion Product Monitoring Aboard Manned Spacecraft

Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.

Briggs, Ryan M.

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)

On the Accuracy of In Situ Water Vapor Measurements in the Troposphere and Lower Stratosphere with the Harvard Lyman-Alpha Hygrometer

In an effort to better constrain atmospheric water vapor mixing ratios and to understand the discrepancies between different measurements of water vapor in the stratosphere and troposphere, we have carefully examined data from the Harvard Lyman-alpha photofragment fluorescence hygrometer, which has flown on the NASA ER-2 aircraft from 1992 through 1998. The instrument is calibrated in the laboratory before and after each deployment, and the calibration is checked by direct absorption measurements in the troposphere. On certain flights, the ER-2 flew level tracks during which water vapor varied by up to 80 ppmv, under nearly constant atmospheric conditions. These flights provide a stringent test of our calibration via direct absorption and indicate agreement to within 3%. During the 1997 Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) mission, our Lyman-alpha instrument was compared with a new diode laser hygrometer from the Jet Propulsion Laboratory. Overall agreement was 5% during the June/July deployment and 1% for potential temperatures of 490 to 540 K. The accuracy of our instrument is shown to be +/-5 %, with an additional offset of at most 0.1 ppmv. Data from this instrument, combined with simultaneous measurements of CH4, and H2, are therefore ideal for studies of the hydrogen budget of the lower stratosphere.

Hintsa, Eric J.

The nu(sub 6), nu(sub 7), nu(sub 8), and nu(sub 10) Bands of HO2NO2

Two new fundamental vibration-rotation bands have been observed for HO2NO2 and assigned. They are nu(sub 7) at 648 1/cm and nu(sub 8) at 466 1/cm. On the basis of these assignments the previously observed bands at 722, 801.5, and 919 1/cm are assigned to nu(sub 10), nu(sub 7) + nu(sub 12), and 2 nu(sub 8), respectively. A partial rotational analysis of the atmospherically relevant nu(sub 6) band has been carried out, and the effects of tunneling, Coriolis interactions, and hot bands on the rotational structure have been characterized.The band origin derived from this analvsisis 8O2.54(sub 3) 1/cm.

Friedl, Randall R.

Data processing and calibration for tunable diode laser harmonic absorption spectrometers

Data processing and calibration methods are described for tunable diode laser absorption spectrometers which produce harmonic absorption spectra as raw data for measuring gas mixing ratios down to parts-per-trillion levels at a variety of pressures. The methods, which take advantage of modern computer speed, memory, and data storage capabilities, are applicable to the detection of weakly absorbing gases in quantitative industrial monitoring, in addition to aircraft and balloon atmospheric measurements for which they were designed. Algorithms for calibration and data analysis, including rejection of erroneous spectra, variation of effective integration time, spectral alignment prior to averaging, and plotting and archiving of results, have been tested on actual stratospheric laser spectra recorded by the Aircraft Laser Infrared Absorption Spectrometer (ALIAS) spectrometer in numerous flights of NASA's ER-2 aircraft.

May, Randy D.

Line intensities and collisional-broadening parameters for the nu4 and nu6 bands of carbonyl fluoride

Line intensities, air- and self-broadening parameters have been measured for selected lines in the nu4 (1243/cm) and nu6 (774/cm) bands of carbonyl fluoride at 296 and 215 K using a tunable diode-laser spectrometer. Measured line intensities are in good agreement +/- 6 percent with recently reported values derived from rotational analyses of the nu4 and nu6 bands. The measured average air-broadening coefficient at 296 K also agrees well (+/- 5 percent) with N2-broadening coefficients determined from microwave studies, while the average self-broadening coefficient reported here is smaller than a previously reported value by 45 percent.

May, Randy D.

Correlation-based technique for automated tunable diode laser scan stabilization

A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.

May, Randy D.

In situ stratospheric measurements of CH4, (C-13)H4, N2O, and OC(O-18) using the BLISS tunable diode laser spectrometer

Simultaneous in situ measurements of stratospheric CH4, (C-13)H4, N2O, OC(O-18), pressure, and temperature have been made from Palestine, Texas (32 deg N) in September 1988 with the JPL Balloon-borne Laser In Situ Sensor. Measurements of CH4 and N2O in the altitude range 30-35 km agree well with other measurements, except for an anomalously high value for the N2O at 31 km. Measurements of CH4 support earlier observations of fold in the vertical profile. A ratio for stratospheric (C-13)H4/CH4 of 0.0105 +/- 0.0010 implies an enrichment of delta(C-13) = -45 +/- 92 parts per thousand over the PDB value, in agreement with previous measurements in the troposphere. A large mixing ratio of 1.9 +/- 0.2 ppmv for OC(O-18) is measured, corresponding to an enrichment of delta(O-18) = 280 +/- 50 parts per thousand for the (O-18) isotopic species over the SMOW value.

Webster, Christopher R.

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.

Computer Processing Of Tunable-Diode-Laser Spectra

Tunable-diode-laser spectrometer measuring transmission spectrum of gas operates under control of computer, which also processes measurement data. Measurements in three channels processed into spectra. Computer controls current supplied to tunable diode laser, stepping it through small increments of wavelength while processing spectral measurements at each step. Program includes library of routines for general manipulation and plotting of spectra, least-squares fitting of direct-transmission and harmonic-absorption spectra, and deconvolution for determination of laser linewidth and for removal of instrumental broadening of spectral lines.

May, Randy D.

Absolute linestrengths in the H2O2 nu6 band

Absolute linestrengths at 295 K have been measured for selected lines in the nu6 band of H2O2 using a tunable diode-laser spectrometer. H2O2 concentrations in a flowing gas mixture were determined by ultraviolet (uv) absorption at 254 nm using a collinear infrared (ir) and uv optical arrangement. The measured linestrengths are approx. 60 percent larger than previously reported values when absorption by hot bands in H2O2 is taken into account.

May, Randy D.