X-ray Source Characteristics from July 2020 SGEMP Experiments at the National Ignition Facility

This report details the measured x-ray characteristics radiating from laser targets on 7 shots at Lawrence Livermore National Laboratory's National Ignition Facility performed June 30 - July 2, 2020. Generally, the x-ray sources were designed to serve as meaningful drivers of a variety of Radiation Effects Sciences response experiments. Specifically, on these 7 shots, the measured x-ray output characteristics and the response experiments serve as a useful data set for validating performance and informing further development of Sandia National Laboratories' EMPIRE code. We present x-ray measurements and analyses relevant to simulating the System-Generated Electro Magnetic Pulse experiments that also occurred on these shots (described elsewhere). Sufficient detail is provided so that a motivated, but novice, x-ray source user could produce some of these analysis results from raw data on similar x-ray shots.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sample test array and recovery (STAR) platform at the National Ignition Facility

We have developed the Sample Test Array and Recovery (STAR) platform for the National Ignition Facility (NIF) for studying the thermal and hydrodynamic responses of materials in extreme environments. The STAR platform expands the range of obtainable fluences and quadruples the rate that materials experiments can be conducted at the NIF. Example configurations are demonstrated for fluences spanning 0.56–34 J/cm 2 with environmental isolation for post-shot material recovery and inspection and up to 1740 J/cm 2 without isolation, with surface heating rates of up to 2 × 10 14 K/s. Lastly, an example experiment involving thermally driven shock and spallation of aluminum alloy 7075 is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD-240 Neutron Detection Efficiency and Sensitivity Calibration

The neutron detection efficiency of the MHD-240 scintillation detector was measured at Ohio University Edwards Accelerator Laboratory. Pulsed broad-spectrum sources from the 27 Al(d,n) and 9 Be(d,n) reactions were used to produce the neutrons. The neutron time-of-flight technique was used to make an energy-differential efficiency measurement. The measurements were made in a low rate pulse mode. The pulse height distribution was also recorded, and the data were used to derive a neutron sensitivity that would be applicable in a high rate environment such as a critical assembly where the detector would be expected to operate in a current mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗