Exploring Oxadiazole Derivative as Anolytes for >3 V Non-Aqueous Redox Flow Battery
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Maurya, Sandipkumar.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Hydrogen production through anion-exchange membrane water electrolyzers (AEMWEs) offers cost advantages over proton-exchange membrane counterparts, mainly due to the good oxygen evolution reaction (OER) activity of platinum-group-metal-free catalysts in alkaline environments. However, the electrochemical oxidation of ionomers at the OER catalyst interface can decrease the local electrode pH, which limits AEMWE performance. Various strategies at the single-cell-level have been explored to address this issue. Here, this work reviews the current understanding of electrochemical ionomer oxidation and strategies to mitigate it, providing our perspective on each approach. Our analysis highlights the competitive adsorption strategy as particularly promising for mitigating ionomer oxidation. This Perspective also outlines future directions for advancing high-performance alkaline AEMWEs and other energy devices using hydrocarbon ionomers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A polyaromatic electrolyte for a fuel cell electrode includes a structure represented by Formula 1, wherein in Formula 1, Ar is a neutral unit represented by one of Formula 2A and Formula 2B: The fuel cell electrode may include a catalyst suspended in the polyaromatic electrolyte.
Fuel Cell R&D programs are the longest running non-weapons programs at LANL, running since 1977. The current DOE HFTO program grew out of the Los Alamos program. It is primarily polymer electrolyte membrame (PEM) technology. The cost and durability are the biggest barriers to commercialization. The program focus is on obtaining fundamental understanding to enable "knowledge-based innovation," and subsequent materials and process development.
Abstract not provided.
Explore the source record for details and available documents.
Non-hydrogen constituents in the fuel steam can cause irreversible damage to FC systems and therefore should be avoided. The objectives are: 1. Develop a low-cost fast response device (analyzer) to measure impurities in a dry hydrogen fuel stream at or above the SAE J2719 levels, 2. Develop understanding of a working mechanism and improve the analyzer by identifying the best materials and their configuration, and 3. Test the analyzer in real-world environments.
In order to improve the durability and ion selectivity of a hydrocarbon membrane for vanadium redox flow batteries (VRFBs) a polymer was rationally designed with an external hydrophobic shell and internal hydrophilic core. The polymer was designed to prevent hydrophilic polymer chain aggregation by functionalizing the external polymer shell with hydrophobic side chains and attaching acid moieties onto the polymer backbone. The hydrophobic shell is the result of pentafluorobenzoyl group functionalization on the pendent aryl rings in a Diels Alder poly(phenylene) backbone. The internal polymer chain contains sulfonic acid moieties to impart hydrophilic character. The physical and electrochemical characteristics of the membrane were systematically studied and compared with widely used Nafion-212. The synthesized membranes were found to be superior to Nafion-212 not only in terms of lower vanadium ion permeability (4.25 x 10 -8 vs. Nafion-212: 6.0 x 10 -6 cm 2 min -1 ) but also in higher VRFB performance (EE = 89% and vs. Nafion-212: 85.5% at 40 mA/cm 2 ). The membrane also showed over three times higher capacity retention than Nafion-212 (0.075 % vs. 0.25 % capacity loss per cycle respectively) and excellent ex situ and in situ chemical stability.
Non-aqueous redox flow batteries (RFBs) have been gaining increased attention in the energy storage arena. Some of their attractive features include the promise for high energy densities, wider voltage windows compared to aqueous systems, as well as wider operating temperature ranges. One of the major challenges in the development of these systems is the lack of electroactive materials that can undergo reversible redox events within the larger potential window of organic solvents. In this paper, we present the design, synthesis, and measurement of electrochemical properties of some iron-based imine- and iminopyridine complexes as promising candidates for RFB applications. Synthesized complexes afforded three reversible redox couples over a ~3 V range. The redox events were also computationally explored and are in good agreement with experimental data. Theoretical calculations show that the redox event at the positive potential can be characterized as metal-centered event corresponding to Fe 3+ → Fe 2+ reduction, while the two redox events at negative potentials are associated with the consecutive reductions of iminopyridine or diimine moieties. This work has led to the identification of a promising anolyte material, [tris(imino)pyridine)Fe][OTf] 2 (1), which is soluble in acetonitrile and is synthesized in two simple steps. This species shows outstanding performance when cycled between 1.0 V and 2.35 V, with 93% coulombic efficiency, 84% energy efficiency, and a capacity decay rate of 0.61% per cycle at 5 mA cm –2 . Further modifications to this kind of charge carrier may lead to the development of high energy density materials for grid scale energy storage applications.
Metal pyrophosphates (MPPs) in general, and tin pyrophosphate (TPP) in particular, have received significant interest in the last decade due to their potential as proton conductors for electrolyte application in intermediate temperature (IT)-fuel cells. However, for MPP based electrolytes, despite high reported proton conductivities, achieving good fuel cell performance and high open circuit voltage (OCV) remains a challenge with synthesis methods playing a crucial role in determining the final proton conductivity. Here we report the role of phosphate precursor in determining the TPP proton conductivity by examining five different precursors: (1) phosphoric acid (TPP-PA), (2) ammonium hydroxide + phosphoric acid (TPP-NH 4 OH), (3) diammonium phosphate (TPP-DAP), (4) tetramethylammonium sulphate + phosphoric acid (TPP-TMAP), and (5) tetrabutylammonium phosphate (TPP-TBAP), where a maximum conductivity of 88 mS cm -1 at 200 °C was obtained for TPP prepared from the TBAP precursor. TPP prepared from all of the different precursors formed the crystalline cubic Pa-3 with combining macron] phase after sintering at 650 °C for 2.5 hours. Furthermore, TPP-TBAP/Nafion® composite membranes prepared with a 90 : 10 ratio exhibited an OCV of 0.98 V and produced a maximum peak power density (PPD) of 630 mW cm -2 at an operating temperature of 220 °C. Our results demonstrate the significant impact of the TPP precursor on proton conductivity and fuel cell performance.
The operation of fuel cells under low relative humidity (RH) conditions gives substantial cost and performance benefits. Nonetheless, it is not currently feasible to operate anion exchange membrane fuel cells (AEMFCs) at low RH conditions because current materials for membrane electrode assembly cannot provide sufficient water for the oxygen reduction reaction. In this work, we synthesized polyfluorene ionomers with different ammonium concentrations for anode and cathode to control water management. We designed several asymmetric electrodes that enable high performance under low RH conditions via not only conventional backward water diffusion (anode to cathode) but also forward diffusion (cathode to anode). The AEMFCs using optimized asymmetric electrodes exhibited high H 2 /CO 2 -free air performance (rated power density of circa 540 mW cm -2 at 90 °C under 75% (anode) and 50% RH (cathode) conditions), which is comparable to those of state-of-the-art AEMFCs under nearly water-saturated conditions. The durability of the AEMFCs is excellent, generating 0.6 A cm -2 for >900 h at 80 °C under 50% RH (cathode) conditions. This study demonstrates that high-performance and durable AEMFCs under low RH and high current generating conditions are possible.
The durability of alkaline anion exchange membrane fuel cells (AEMFCs) is a critical requirement for implementing this technology in cost-effective energy conversion. However, the lifetime of current AEMFCs is short, ca. < 1,000 h and the cause of the performance loss over time is poorly understood. Here, we investigate the origin of AEMFC unrecoverable performance loss. We diagnosed the recoverable performance loss induced by carbonation and anode flooding during an extended-term test with transient operating conditions. Multiple extended-term tests under current densities and the electrochemical and analytical analyses suggest that the most prominent permanent performance loss of AEMFCs occurs by phenol formation as a result of electrochemical phenyl oxidation of cathode ionomeric binder. The produced phenol is acidic and neutralizes the quaternary ammonium group to lower the local pH. Finally, the impact of this degradation pathway is discussed to explain the reported lifetime performance of current AEMFCs.
Explore the source record for details and available documents.
We report that addition of flow fields to carbon paper electrodes in a vanadium redox flow battery (VRFB) can improve the peak power density through uniform distribution of electrolyte in the electrodes. However, it is unclear whether flow fields have a similar effect with graphite felt electrodes, as VRFBs with felt electrodes reported in literature show a large anomaly in obtained power density. In this work, we evaluate three flow fields; viz. serpentine, interdigitated and conventional (without flow pattern) type with felt electrodes and compare their performance with a serpentine flow field using carbon paper electrodes under identical experimental conditions. The conventional flow field provides highest energy efficiency (75%) followed by serpentine (64%) and interdigitated (55%) at 0.2 A cm -2 attributable to the deteriorating electrolyte distribution in the electrodes. Computation fluid dynamic simulations confirm the experimental finding of worsening electrolyte distribution (conventional < serpentine < interdigitated). A power density of 0.51 W cm -2 at 60 mL min -1 flow rate is obtained for serpentine and conventional flow fields with felt electrodes; comparable to the highest power density reported in literature for high performing zero-gap flow field architecture. Finally, this paper gives comprehensive insights on flow fields for VRFBs that can be extended to other flow batteries.