Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

The EGS Collab Project: Status and Accomplishments

The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed.

EGS Collab↗

Field Experiments and Model Validation: The EGS Collab Project

Implementing enhanced geothermal systems (EGS) will require improvements in understanding stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The US Department of Energy (DOE) is addressing these and other challenges at multiple scales. The EGS Collab project, addressed here, is performing tests and modeling at the 10 m scale. The FORGE project is performing tests at the full reservoir scale. The EGS Collab team created an underground testbed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently building a second testbed at SURF at a depth of about 1.25 km aimed at investigating shear stimulation (Experiment 2). In Experiment 1, we drilled eight boreholes in a well-characterized phyllite and installed geophysical sensors in six of them to create a well-instrumented testbed to allow careful monitoring of stimulation events and flow tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results both in near-real-time and in detailed process studies. Stimulations performed in this testbed allowed quantification of processes occurring during stimulation and the examination of dynamic flow occurrences. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Our second testbed, targeted at shear stimulation, is currently being built at the SURF Facility at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1.

artificial intelligence↗