Localization of a radioactive source in an urban environment using Bayesian Metropolis methods [Bayesian Metropolis methods for source localization in an urban environment]

Here, we present a method for localizing an unknown source of radiation in an urban environment using a distributed detector network. This method employs statistical parameter estimation techniques, relying on an approximation for the response of a detector to the source based on a simplified model of the underlying transport phenomena, combined with a Metropolis-type sampler that is modified to propagate the effect of fixed epistemic uncertainties in the material macroscopic cross sections of objects in the scene. We apply this technique to data collected during a measurement campaign conducted in a realistic analog for an urban scene using a network of six mobile detectors. Our initial results are able to localize the source to within approximately 8 m over a scene of size 300 m 200 m in two independent trials with 30 min count times, including a characterization of the uncertainty associated with the poorly known macroscopic cross sections of objects in the scene. In these measurements, the nearest detectors were between 20 m to 30 m from the source, and recorded count rates between approximately 3 and 13 times background. A few detectors had line-of-sight to the source, while the majority were obscured by objects present in the scene. After extending our model to account for the orientation of the detectors and correcting for anomalies in the measurement data we were able to further improve the localization accuracy to approximately 2 m in both trials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated defect detection in spent nuclear fuel using combine Cerenkov and Gamma Emission Tomography data

Spent fuel monitoring and characterization has been a pillar of safeguards and nuclear facility monitoring for many years. The Digital Cerenkov Viewing Device (DCVD) has been used since the 1980s as a method of defect detection in spent fuel. In recent years, the accounting of large quantities of spent fuel before storage has renewed interest in this relatively quick and inexpensive method. This has an impact not only in safeguards, but also in for nuclear power facilities, as accounting can be a long and arduous process. Additionally, the DCVD demonstrates limited accuracy in more complex cases such as substitution of a fuel rod with steel, or a partial defect detection. A second method, Gamma Emission Tomography (GET) has been explored as an improved defect detection method, but is much more expensive and invasive than DCVD. This work identifies deficiencies in both methods, and proposes a combination of data gathered from each method to address these deficiencies for improved spent fuel characterization. Initial results are promising, showing 97% detection of a single missing fuel rod when the data types are combined, versus approximately 50% and 70%respectively for DCVD and GET data on their own. Finally, these classification results are obtained with algorithms derived from facial recognition and applied to this problem, yielding unique accuracy in near real-time while also maintaining the information barrier between output and measurement desired in safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Radiation Detection Using a Mixed-Effects Statistical Model for Background Variation

In this paper, we consider radiation source localization in an urban environment as an inverse problem and use Bayesian parameter estimation techniques to infer the source location and intensity. Since parameter estimation generally requires a large number of model evaluations, we employ a simplified photon transport model, as in a 2017 paper by Stefanescu, et al., to reduce computational requirements. However, the model in the 2017 paper does not account for the physical reality that background radiation varies with position within an urban locale. We incorporate statistical mixed-effects modeling into the simplified transport equation from the Stefanescu, et al. paper to reflect individual variation among the background radiation measurements at multiple detector locations. With our new model, we use a Bayesian DRAM-within-Gibbs technique, which incorporates the Delayed Rejection Adaptive Metropolis (DRAM) algorithm, to estimate the mixed-effects parameters. We note that without adequate prior information, we were unable to simultaneously estimate the set of parameters corresponding to the source intensity, source location, and individual background radiation counts. By calibrating the background in the absence of a source, we obtained narrow prior distributions, which permitted us to jointly infer the source intensity and location and the background radiation distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity Analysis of Neutron Multiplicity Counting Statistics Using First-Order Perturbation Theory and Application to a Subcritical Plutonium Metal Benchmark

It is frequently important to estimate the uncertainty and sensitivity of measured and computed detector responses in subcritical experiments and simulations. These uncertainties arise from the physical construction of the experiment, uncertainties in the transport parameters, and counting uncertainties. Perturbation theory enables sensitivity analysis (SA) and uncertainty quantification on integral quantities like detector responses. Here the aim of our work is to apply SA to the statistics of subcritical neutron multiplicity counting distributions. Current SA methods have only been applied to mean detector responses and the keff eigenvalue. For multiplicity counting experiments, knowledge of the higher-order counting moments and their uncertainties are essential for a complete SA. We apply perturbation theory to compute the sensitivity of neutron multiplicity counting moments to arbitrarily high order. Each moment is determined by solving an adjoint transport equation with a source term that is a function of the adjoint solutions for lower-order moments. This enables moments of arbitrarily high order to be sequentially determined, and it shows that each moment is sensitive to the uncertainties of all lower-order moments. To close our SA of the moments, we derive forward transport equations that are functions of the forward flux and lower-order moment adjoint fluxes. We verify our calculations for the first three moments by comparison with multiplicity counting measurements of a subcritical plutonium metal sphere. For the first three moments, the most influential parameters are ranked, and the validity of first-order perturbation theory is demonstrated by examining the series truncation error. This enables a detailed SA of subcritical multiplicity counting measurements of fissionable material based on transport theory.

42 ENGINEERING↗

Hybrid optimization and Bayesian inference techniques for a non-smooth radiation detection problem

In this paper, we propose several algorithms to recover the location and intensity of a radiation source located in a simulated 250 × 180 m block of an urban center based on synthetic measurements. Radioactive decay and detection are Poisson random processes, so we employ likelihood functions based on this distribution. Owing to the domain geometry and the proposed response model, the negative logarithm of the likelihood is only piecewise continuous differentiable, and it has multiple local minima. To address these difficulties, we investigate three hybrid algorithms composed of mixed optimization techniques. For global optimization, we consider simulated annealing, particle swarm, and genetic algorithm, which rely solely on objective function evaluations; that is, they do not evaluate the gradient in the objective function. By employing early stopping criteria for the global optimization methods, a pseudo-optimum point is obtained. This is subsequently utilized as the initial value by the deterministic implicit filtering method, which is able to find local extrema in non-smooth functions, to finish the search in a narrow domain. These new hybrid techniques, combining global optimization and implicit filtering address, difficulties associated with the non-smooth response, and their performances, are shown to significantly decrease the computational time over the global optimization methods. To quantify uncertainties associated with the source location and intensity, we employ the delayed rejection adaptive Metropolis and DiffeRential Evolution Adaptive Metropolis algorithms. Finally, marginal densities of the source properties are obtained, and the means of the chains compare accurately with the estimates produced by the hybrid algorithms.

42 ENGINEERING↗

Validation and uncertainty of DRF's for a 1"×2" NaI collimated detector for radioisotope holdup measurements

Detector response functions (DRFs) have become the subject of increasing scientific interest for the last thirty years in several industrial applications of radiation detection. These applications include gamma-ray, prompt gamma-ray, and X-ray spectrometry for elemental analysis and location as applied to mining, radio-tracing in medicine, and holdup source characterization. However, it is difficult to create a rigorous mathematical formulation of the DRF. Therefore, semi-empirical and stochastic approaches have been developed instead to construct detector and application specific DRFs. A DRF can be considered to be a function that converts the energy-dependent incidence of incoming source particles onto a detector into a detector response spectrum that simulates the experimental response. The DRF can also be used in the reverse sense in an inverse problem setting, as a step in the process of predicting the physical characteristics of an unknown source (e.g. the holdup problem and library spectra). Much of the recent work on DRFs has been performed by Gardner. He has developed accurate DRF models through semi-empirical curve fitting and Monte Carlo simulation. His DRFs for 3" X 3" NaI detectors have been developed with the experimental measurements taken by Heath and for 6"x6" bare (unshielded) NaI(Tl) detector data with single-energy sources centered on the detector face at a distance of 10 cm. There was agreement with the Heath benchmark detector measurements within two Poisson standard deviations of the measured data. DRFs have also been developed for other detectors such as high purity Germanium detectors and Si(Li) for the same geometries as NaI. Other than a few artifacts such as backscatter peaks, there was good agreement between simulated responses and the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗