Engineering PapersSearch

Engineering topics

Matteson, J.

Publications and source records attributed to Matteson, J..

The INTEGRAL scatterometer SPI

The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.

Mandrou, P.

Compton-backscattered annihilation radiation from the Galactic Center region

On 1989 May 22, the High Energy X-ray and Gamma-ray Observatory for Nuclear Emissions, a balloon-borne high-resolution germanium spectrometer with an 18-deg FOV, observed the Galactic Center (GC) from 25 to 2500 keV. The GC photon spectrum is obtained from the count spectrum by a model-independent method which accounts for the effects of passive material in the instrument and scattering in the atmosphere. Besides a positron annihilation line with a flux of (10.0 +/- 2.4) x 10 exp -4 photons/sq cm s and a full width at half-maximum (FWHM) of (2.9 + 1.0, -1.1) keV, the spectrum shows a peak centered at (163.7 +/- 3.4) keV with a flux of (1.55 +/- 0.47) x 10 exp -3 photons/sq cm s and a FWHM of (24.4 +/- 9.2) keV. The energy range 450-507 keV shows no positronium continuum associated with the annihilation line, with a 2-sigma upper limit of 0.90 on the positronium fraction. The 164 keV feature is interpreted as Compton backscatter of broadened and redshifted annihilation radiation, possibly from the source 1E 1740.7-2942.

Smith, D. M.

BATSE observations of gamma-ray burst spectra. I - Spectral diversity

We studied the time-averaged gamma-ray burst spectra accumulated by the spectroscopy detectors of the Burst and Transient Source Experiment. The spectra are described well at low energy by a power-law continuum with an exponential cutoff and by a steeper power law at high energy. However, the spectral parameters vary from burst to burst with no universal values. The break in the spectrum ranges from below 100 keV to more than 1 MeV, but peaks below 200 keV with only a small fraction of the spectra breaking above 400 keV; it is therefore unlikely that a majority of the burst spectra are shaped directly by pair processes, unless bursts originate from a broad redshift range. The correlations among burst parameters do not fulfill the predictions of the cosmological models of burst origin. No correlations with burst morphology or the spatial distribution were found. We demonstrate the importance of using a complete spectral description even if a partial description (e.g., a model without a high-energy tail) is statistically satisfactory.

Band, D.

BATSE spectroscopy detector calibration

We describe the channel-to-energy calibration of the Spectroscopy Detectors of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (GRO). These detectors consist of NaI(TI) crystals viewed by photomultiplier tubes whose output in turn is measured by a pulse height analyzer. The calibration of these detectors has been complicated by frequent gain changes and by nonlinearities specific to the BATSE detectors. Nonlinearities in the light output from the NaI crystal and in the pulse height analyzer are shifted relative to each other by changes in the gain of the photomultiplier tube. We present the analytical model which is the basis of our calibration methodology, and outline how the empirical coefficients in this approach were determined. We also describe the complications peculiar to the Spectroscopy Detectors, and how our understanding of the detectors' operation led us to a solution to these problems.

Band, D.

Spectral evolution of gamma-ray bursts

BATSE's Spectral Detectors provide a series of high resolution spectra over the duration of a gamma-ray burst; fits to these spectra show the evolution of the continuum as the burst progresses. The burst continuum can usually be fit by the spectral form AE sup alpha exp(-E/kT) from around 25 keV to more than 3 MeV, with varying trends in the value and evolution of the spectral parameters. As a result of limited statistics for E greater than 1 - 2 MeV in the individual spectra, a high energy power law is not required. Only long duration strong bursts can be studied by fitting a series of spectra, and therefore our conclusions concern only this class of burst. The bursts we analyzed tend to be characterized by a hard-to-soft trend both for individual intensity spikes and for the burst as a whole: the hardness leads the count rate in spectra which resolve the temporal variations, while the hardness of successive spikes decreases. We also summarize the performance of the Spectral Detectors and the development of analysis tools to date.

Band, D.

An observation of annihilation radiation from the Galactic center region

Results are reported from observations of the 511 MeV annihilation gamma-ray line from the Galactic center, made on May 22, 1989 with a high-resolution gamma-ray spectrometer on board a balloon launched from Alice Springs (Australia). The observations were made at about 4 gm/sq cm atmospheric depth for 6 hrs in a series of target and background pointings lasting 20 min each. The results obtained from multiparameter Gaussian fits to the data were as follows: 511 keV flux = 0.00089 + or - 0.00027 ph/sq cm per sec-rad, line width of about 1.1 keV, and less than 3.2 keV FWHM at 95 percent confidence.

Matteson, J.

An observation of the Galactic center region with the HEXAGONE high resolution gamma-ray spectrometer

The Galactic center region was observed for 6 hours on May 22, 1989 from a high altitude balloon with the HEXAGONE high resolution gamma-ray spectrometer. The instrument had a 285 sq/cm array of cooled germanium detectors with an energy resolution of 2.2 keV at 511 keV and an 18 deg FWHM field of view. The 511 keV gamma-rays from electron-positron annihilation and 1809 keV gamma-rays from the radioactive decay of Al-26 were observed to have fluxes of 8.9 x 10 exp -4 and 1.9 x 10 exp -4 ph/cm-s, respectively. Continuum emission was detected from 20 to 800 keV and preliminary results have been obtained for the spectrum. Below 120 keV this is well described by power law with a slope of -2.6. In the 120-250 keV band the spectrum contains a broad linelike feature. This is interpreted as the result of Compton backscattering of about 511 keV photons from a compact source of electron-positron annihilation radiation.

Matteson, J.

A-4 scientific results

Observations of galactic sources, extragalactic sources and gamma bursts with the A-4 instrument at energy 1 energies of between 0.1 to 10 MeV are discussed. Aximuthal scans are presented. The Crab Nebula and its spectrum and the spectrum of Cygnus Z-1 are described.

Matteson, J.