Engineering PapersSearch

Engineering topics

Mather, J. C.

Publications and source records attributed to Mather, J. C..

At least 37 records · Page 2

Calibration of the COBE FIRAS instrument

The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite was designed to accurately measure the spectrum of the cosmic microwave background radiation (CMBR) in the frequency range 1-95/cm with an angular resolution of 7 deg. We describe the calibration of this instrument, including the method of obtaining calibration data, reduction of data, the instrument model, fitting the model to the calibration data, and application of the resulting model solution to sky observations. The instrument model fits well for calibration data that resemble sky condition. The method of propagating detector noise through the calibration process to yield a covariance matrix of the calibrated sky data is described. The final uncertainties are variable both in frequency and position, but for a typical calibrated sky 2.6 deg square pixel and 0.7/cm spectral element the random detector noise limit is of order of a few times 10(exp -7) ergs/sq cm/s/sr cm for 2-20/cm, and the difference between the sky and the best-fit cosmic blackbody can be measured with a gain uncertainty of less than 3%.

Fixsen, D. J.

Scientific results from COBE

NASA's Cosmic Background Explorer (COBE) carries three scientific instruments to make precise measurements of the spectrum and anisotropy of the cosmic microwave background (CMB) radiation on angular scales greater than 7 deg and to conduct a search for a diffuse cosmic infrared background (CIB) radiation with 0.7 deg angular resolution. Data from the Far-Infrared Absolute Spectrophotometer (FIRAS) show that the spectrum of the CMB is that of a blackbody of temperature T = 2.73 +/- 0.06 K, with no deviation from a blackbody spectrum greater than 0.25% of the peak brightness. The first year of data from the Differential Microwave Radiometers (DMR) show statistically significant CMB anisotropy. The anisotropy is consistent with a scale invariant primordial density fluctuation spectrum. Infrared sky brightness measurements from the Diffuse Infrared Background Experiment (DIRBE) provide new conservative upper limits to the CIB. Extensive modeling of solar system and galactic infrared foregrounds is required for further improvement in the CIB limits.

Bennett, C. L.

The COBE mission - Its design and performance two years after launch

The COBE mission, NASA's first space mission devoted primarily to cosmology, is described and the spacecraft concepts central to enabling the mission to achieve its scientific objectives are examined. The major components of the COBE instrument and spacecraft modules are shown and their characteristics are given. Early scientific results are summarized and plans for continuing satellite operations and data analysis are addressed.

Boggess, N. W.

Interpretation of the cosmic microwave background radiation anisotropy detected by the COBE Differential Microwave Radiometer

The large-scale cosmic background anisotropy detected by the COBE Differential Microwave Radiometer (DMR) instrument is compared to the sensitive previous measurements on various angular scales, and to the predictions of a wide variety of models of structure formation driven by gravitational instability. The observed anisotropy is consistent with all previously measured upper limits and with a number of dynamical models of structure formation. For example, the data agree with an unbiased cold dark matter (CDM) model with H0 = 50 km/s Mpc and Delta-M/M = 1 in a 16 Mpc radius sphere. Other models, such as CDM plus massive neutrinos (hot dark matter (HDM)), or CDM with a nonzero cosmological constant are also consistent with the COBE detection and can provide the extra power seen on 5-10,000 km/s scales.

Wright, E. L.

COBE differential microwave radiometers - Calibration techniques

The COBE spacecraft was launched November 18, 1989 UT carrying three scientific instruments into earth orbit for studies of cosmology. One of these instruments, the Differential Microwave Radiometer (DMR), is designed to measure the large-angular-scale temperature anisotropy of the cosmic microwave background radiation at three frequencies (31.5, 53, and 90 GHz). This paper presents three methods used to calibrate the DMR. First, the signal difference between beam-filling hot and cold targets observed on the ground provides a primary calibration that is transferred to space by noise sources internal to the instrument. Second, the moon is used in flight as an external calibration source. Third, the signal arising from the Doppler effect due to the earth's motion around the barycenter of the solar system is used as an external calibration source. Preliminary analysis of the external source calibration techniques confirms the accuracy of the currently more precise ground-based calibration. Assuming the noise source behavior did not change from the ground-based calibration to flight, a 0.1-0.4 percent relative and 0.7-2.5 percent absolute calibration uncertainty is derived, depending on radiometer channel.

Bennett, C. L.

Preliminary spectral observations of the Galaxy with a 7 deg beam by the Cosmic Background Explorer (COBE)

The FIR absolute spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) has carried out the first all-sky spectral line survey in the FIR region, as well as mapping spectra of the Galactic dust distribution at below 100 microns. Lines of forbidden C I, C II, and N II, as well as of CO are all clearly detected. The mean line intensities are interpreted in terms of the heating and cooling of the multiple phases of the interstellar gas. In addition, an average spectrum of the galaxy is constructed and searched for weak lines. The spectrum of the galaxy observed by FIRAS has two major components: a continuous spectrum due to interstellar dust heated by starlight, and a line spectrum dominated by the strong 158-micron line from singly ionized carbon, with a spatial distribution similar to the dust distribution, and a luminosity of 0.3 percent of the dust luminosity. There are in addition moderately strong 122- and 205.3-micron lines, identified as coming from singly-ionized nitrogen. Maps of the emission by dust and forbidden C II and N II are presented.

Wright, E. L.

Early results from the Cosmic Background Explorer (COBE)

Data obtained with the FIR Absolute Spectrophotometer, Differential Microwave Radiometers, and Diffuse IR Background Experiment (DIRBE) on the COBE satellite since its launch in November 1989 are briefly characterized. The COBE spacecraft and its 900-km 99-deg orbit are described; the scientific goals and capabilities of the instruments are reviewed; and sample DIRBE data are presented in a map and graph. Upper limits on the Comptonization parameter (y less than 0.001) and the chemical potential (mu less than 0.01 at the 3sigma level) are determined, and the spectrum of the dipole anisotropy is shown to be that of a Doppler-shifted blackbody. The DIRBE 100-micron sky brightness values at the ecliptic poles are found to be significantly lower than those measured by IRAS.

Mather, J. C.

Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)

The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.

Mather, J. C.

Early results from the Cosmic Background Explorer (COBE)

The Cosmic Background Explorer, launched 18 Nov. 1989, has nearly completed its first full mapping of the sky with all three of its instruments: A Far Infrared Absolute Spectrometer (FIRAS) covering 0.1 to 10 mm, a set of Differential Microwave Radiometers (DMR) operating at 3.3, 5.7, and 9.6 mm, and a diffuse Infrared Background Experiment (DIRBE) spanning 1 to 300 microns in ten bands. A preliminary map of the sky derived from DIRBE data is presented. Initial cosmological implications include: a limit on the comptonization parameter of 0.001, on the chemical potential parameter of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy has the spectrum expected from a Doppler shift of a blackbody. There are no significant anisotropies in the microwave sky detected, other than from our own galaxy and a cos theta dipole anisotropy whose amplitude and direction agree with previous data. At shorter wavelengths, the sky spectrum and anisotropies are dominated by emission from local sources of emission within our Galaxy and Solar System. Preliminary comparison of IRAS (Infrared Astronomical Satellite) and DRIBE sky brightnesses toward the ecliptic poles shows the IRAS values to be significantly higher than found by DRIBE at 100 microns. The presence of gain and zero point errors in the IRAS total brightness data is suggested. The spacecraft, instrument designs, and data reduction methods are described.

Mather, J. C.

A preliminary measurement of the cosmic microwave background spectrum by the Cosmic Background Explorer (COBE) satellite

A preliminary spectrum is presented of the background radiation between 1 and 20/cm from regions near the north Galactic pole, as observed by the FIRAS instrument on the COBE satellite. The spectral resolution is 1/cm. The spectrum is well fitted by a blackbody with a temperature of 2.735 + or - 0.06 K, and the deviation from a blackbody is less than 1 percent of the peak intensity over the range 1-20/cm. These new data show no evidence for the submillimeter excess previously reported by Matsumoto et al. (1988) in the cosmic microwave background. Further analysis and additional data are expected to improve the sensitivity to deviations from a blackbody spectrum by an order of magnitude.

Mather, J. C.

Capabilities of the cosmic background explorer

The cosmic background explorer, now being redesigned for a launch on a Delta rocket in 1989, will carry three instruments to measure the cosmic infrared and microwave background radiation and other diffuse sources from 1 micron to 1 cm wavelength. These instruments will be orders of magnitude more sensitive and accurate than previous equipment and will help determine the structure of the early universe. The instruments are (1) an absolute spectrophotometer, covering 100 microns to 1 cm, (2) an absolute infrared radiometer covering 1 to 300 microns, and (3) differential microwave radiometers at 32, 53, and 90 GHz. They will measure the large scale anisotropy and the spectrum of the 3 K cosmic background, and search for the extragalactic infrared background, to a sensitivity limited by the astrophysical environment. The first two instruments require liquid helium cooling, limiting their lifetime to about 14 months.

Mather, J. C.

Heat trap with flare as multimode antenna

A heat trap, also called a Winston cone or compound parabolic concentrator, has been designed and built to serve as the beam defining optic for the far-infrared absolute spectrophotometer on the Cosmic Background Explorer satellite. This quasi-optical multimode antenna is coupled to a flared entrance section shaped like a trumpet bell to reduce response to off-axis radiation. The antenna has very low sidelobes over a two-decade frequency range from 1 to 100/cm. Fabrication is described, and stray light data are presented and compared to theory. A novel optical figure test for concentrators is presented.

Mather, J. C.

Submillimeter and millimeter wave characterization of absorbing materials

Several microwave absorbers have been characterized in terms of transmittance and reflectance at frequencies between 35 GHz and 3 THz. The materials studied were a series of iron-loaded cast epoxy absorbers known as Eccosorb. Measurements show that reflectance and absorption coefficient increase with the iron density. A dramatic decrease, by as much as a factor of 2, in absorption coefficient was observed when the samples were cooled from ambient to cryogenic temperatures. A blackbody calibrator to be operated at liquid helium temperature was constructed using the measured optical constants for these absorbers. The measured absorption coefficient for cold Eccosorb CR-110 is within 20 percent of that reported recently by Peterson and Richards.

Hemmati, H.

Michelson interferometer with separated inputs and outputs, double pass, and compensation

A novel configuration is proposed for a Michelson interferometer spectrometer, which will be insensitive to tilts or displacements, and which employs separated inputs and outputs and double passing for higher resolution. The great advantage of such a compensated design is a relaxation of mechanical tolerances, which is especially beneficial for instruments in hostile environments. The Atmospheric Trace Molecule Spectroscopy project, which must work reliably after being subjected to the vibrations of a Space Shuttle launch, would benefit from the use of such an instrument.

Mather, J. C.

Thermal detectors as single photon X-ray spectrometers

In a thermal detector employed for X-ray spectroscopy applications, the energy of an X-ray is converted to heat in a small mass, and the energy of that X-ray inferred from the size of the temperature rise. The present investigation is concerned with the possibility to make an extremely low heat capacity calorimeter which can be employed as a thermal detector. Several types of calorimeters were fabricated and tested at temperatures as low as approximately 0.05 K. The obtained devices make use of thermistors constructed of melt-doped silicon, nuclear transmutation doped (NTD) germanium, and ion-implanted silicon with a variety of materials for the support and electrical leads. The utility of these microcalorimeters as X-ray spectrometers could be verified.

Moseley, S. H.

Submillimeter wavelength survey of the galactic plane from l = -5 deg to l = +62 deg - Structure and energetics of the inner disk

Observational results are presented from a new large-scale survey of the first quadrant of the galactic plane at wavelengths of 150, 250, and 300 microns, with a 10 x 10 arcmin beam. The emission detected in the survey arises from compact sources, most of which are identified with known peaks of 5 GHz or CO emission, or both, and from an underlying diffuse background with a typical angular width of about 0.9 deg (FWHM) which accounts for most of the emission. A total of 80 prominent discrete sources are identified and characterized, of which about half have not previously been reported at far-infrared wavelengths. The total infrared luminosity within the solar circle is about 1 to 2 x 10 to the 10th solar luminosity, and is probably emitted by dust that resides in molecular clouds.

Hauser, M. G.

Electrical self-calibration of nonideal bolometers

An analytical method for determining the absorbed energy calibration of an IR bolometer from purely electrical measurements is presented. The technique is targeted at detectors with purely electrical nonlinearities. It is shown that the responsivity can be derived from the I-V plot if the limiting high-frequency impedance is measured. The electrical nonlinearity is then the difference between the impedance and the dc resistance. The model is used for designing a circuit for measuring the relative impedance parameters. The results are applicable to studies of IR sources and the detection of energy pulses with bolometers.

Mather, J. C.

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.