Engineering PapersSearch

Engineering topics

Mason, S.

Publications and source records attributed to Mason, S..

Integration of Optical Coherence Tomography Scan Patterns to Augment Clinical Data Suite

Vision changes identified in long duration spaceflight astronauts has led Space Medicine at NASA to adopt a more comprehensive clinical monitoring protocol. Optical Coherence Tomography (OCT) was recently implemented at NASA, including on board the International Space Station in 2013. NASA is collaborating with Heidelberg Engineering to increase the fidelity of the current OCT data set by integrating the traditional circumpapillary OCT image with radial and horizontal block images at the optic nerve head. The retinal nerve fiber layer was segmented by two experienced individuals. Intra-rater (N=4 subjects and 70 images) and inter-rater (N=4 subjects and 221 images) agreement was performed. The results of this analysis and the potential benefits will be presented.

Mason, S.

Operational Transition from the First-Generation Heidelberg Spectralis Optical Coherence Tomography [OCT("OCT1")] to the Second-Generation Heidelberg Spectralis OCT("OCT2")

The Heidelberg Spectralis "OCT2", which recently became commercially available, is going to be implemented at the Johnson Space Center Flight Medicine Clinic and on board the International Space Station. Due to the increased scan rate of the "OCT2", this upgrade will allow for significant reduction in valuable crew testing time and also allow for additional capabilities, like OCT Angiography and Multi-Color Fundus Imaging. Due to the custom scans used to monitor Space Flight-Associated Neuro-ocular Syndrome (SANS) in our crewmembers, an evaluation to assess the impacts of transitioning from "OCT1" to "OCT2" was performed. An engineering assessment (N=1) was performed to identify any potential impacts of maintaining an "OCT1" on board ISS while implementing an "OCT2" in the JSC Clinic. "OCT2" implementation will lag JSC FMC clinical implementation due to the flight certification/manifestation process. The clinical assessment was performed (n=12) to identify any impacts due to the replacement of the "OCT1" with the "OCT2" to the longitudinal OCT data across a crewmember's mission/lifetime. The qualitative results from the engineering and clinical evaluation will be reported, as well as the quantitative assessment of the clinical variables

Mason, S.

Exploratory Analysis of Carbon Dioxide Levels, Ultrasound and Optical Coherence Tomography Measures of the Eye During ISS Missions

Enhanced screening for the Visual Impairment/Intracranial Pressure (VIIP) syndrome has been implemented to better characterize the ocular and vision changes observed in some long-duration crewmembers. This includes implementation of in-flight ultrasound in 2010 and optical coherence tomography (OCT) in 2013. Potential risk factors for VIIP include cardiovascular health, diet, anatomical and genetic factors, and environmental conditions. Carbon dioxide (CO2), a potent vasodilator, is chronically elevated on the International Space Station (ISS) relative to ambient levels on Earth, and is a plausible risk factor for VIIP. In an effort to understand the possible associations between CO2 and VIIP, this study explores the relationship of ambient CO2 levels on ISS compared to inflight ultrasound and OCT measures of the eye obtained from ISS crewmembers. CO2 measurements were aggregated from Operational Data Reduction Complex and Node 3 major constituent analyzers (MCAs) on ISS or from sensors located in the European Columbus module, as available. CO2 levels in the periods between each ultrasound and OCT session are summarized using timeseries metrics, including time-weighted means and variances. Partial least squares regression analyses are used to quantify the complex relationship between specific ultrasound and OCT measures and the CO2 metrics simulataneously. These analyses will enhance our understanding of the possible associations between CO2 levels and structural changes to the eye which will in turn inform future analysis of inflight VIIP data.

Schaefer, C.

Exploratory Analysis of Carbon Dioxide Levels, Ultrasound and Optical Coherence Tomography Measures of the Eye During ISS Missions

Carbon dioxide (CO2) levels on board the International Space Station (ISS) have typically averaged 2.3 to 5.3 mmHg, with large fluctuations occurring over periods of hours and days. CO2 has effects on cerebral vascular tone, resulting in vasodilation and alteration of cerebral blood flow (CBF). Increased CBF leads to elevated intracranial pressure (ICP), a factor leading to visual disturbances, headaches, and other central nervous system symptoms. Ultrasound of the optic nerve and optical coherence tomography (OCT) provide surrogate measurements of ICP; in-flight measurements of both were implemented as enhanced screening tools for the Visual Impairment/Intracranial Pressure (VIIP) syndrome. This analysis examines the relationships between ambient CO2 levels on ISS, ultrasound and OCT measures of the eye in an effort to understand how CO2 may possibly be associated with VIIP and to inform future analysis of in-flight VIIP data.

Schaefer, C.

Exploration Analysis of Carbon Dioxide Levels and Ultrasound Measures of the Eye During ISS Missions

Enhanced screening for the Visual Impairment/Intracranial Pressure (VIIP) Syndrome, including in-flight ultrasound, was implemented in 2010 to better characterize the changes in vision observed in some long-duration crewmembers. Suggested possible risk factors for VIIP include cardiovascular changes, diet, anatomical and genetic factors, and environmental conditions. As a potent vasodilator, carbon dioxide (CO (sub 2)), which is chronically elevated on the International Space Station (ISS) relative to typical indoor and outdoor ambient levels on Earth, seems a plausible contributor to VIIP. In an effort to understand the possible associations between CO (sub 2) and VIIP, this study analyzes the relationship between ambient CO (sub 2) levels on ISS and ultrasound measures of the eye obtained from ISS fliers. CO (sub 2) measurements will be pulled directly from Operational Data Reduction Complex for the Lab and Node 3 major constituent analyzers (MCAs) on ISS or from sensors located in the European Columbus module, as available. CO (sub 2) measures between ultrasound sessions will be summarized using standard time series class metrics in MATLAB including time-weighted means and variances. Cumulative CO (sub 2) exposure metrics will also be developed. Regression analyses will be used to quantify the relationships between the CO (sub 2) metrics and specific ultrasound measures. Generalized estimating equations will adjust for the repeated measures within individuals. Multiple imputation techniques will be used to adjust for any possible biases in missing data for either CO (sub 2) or ultrasound measures. These analyses will elucidate the possible relationship between CO (sub 2) and changes in vision and also inform future analysis of inflight VIIP data.

Young, M.

Exploratory Analysis of Carbon Dioxide Levels and Ultrasound Measures of the Eye During ISS Missions

Carbon dioxide (CO2) levels on ISS have typically averaged 2.3 to 5.3mm Hg, with large fluctuations occurring over periods of hours and days. CO2 has effects on cerebral vascular tone, resulting in vasodilation and alteration of cerebral blood flow(CBF). Increased CBF leads to elevated intracranial pressure(ICP), which is a factor leading to visual disturbance, headaches, and other central nervous system symptoms. Ultrasound of the optic nerve provides a surrogate measurement of ICP. Inflight ultrasounds were implemented as an enhanced screening tool for the Visual Impairment/Intracranial Pressure (VIIP) Syndrome. This analysis examines the relationships between ambient CO2 levels on ISS and ultrasound measures of the eye in an effort to understand how CO2 may be associated with VIIP and to inform future analysis of inflight VIIP data. Results as shown in Figure2, there was a large timeframe where CO2 readings were removed due to sensor fault errors(see Limitations), from June 2011 to January 2012. After extensive cleaning of the CO2 data, metrics for all of the data were calculated (Table2). Preliminary analyses showed possible associations between variability measures of CO2 and AP diameter (Figure3),and average CO2 exposure and ONSD(Figure4). Adjustments for multiple comparisons were not made due to the exploratory nature of the analysis.

Schaefer, C.

The Relationship Between CO2 Levels and CO2 Related Symptoms Reported on the ISS

Medical Operations, Toxicology, and the Lifetime Surveillance of Astronaut Health collaborated to assess the association of CO2 levels on board the International Space Station and USOS crew reported symptoms inflight, i.e. headache and vision changes. Private Medical Conference (PMC) documents and the weekly Space Medicine Operations Team (SMOT) Notes were used to provide a robust data set of inflight medical events. All events and non‐events were documented independent of CO2 levels and other potential contributors. Average (arithmetic mean) and single point maximum ppCO2 was calculated for the 24 hours and 7 days prior to the PMC or SMOT date and time provided by LSAH. Observations falling within the first 7 days of flight (147) were removed from the datasets analyzed to avoid confounding with Space Adaptation Syndrome. The final analysis was based on 1716 observations. For headache, 46 headaches were observed. CO2 level, age at launch, time inflight, and data source were all significantly associated with headache. In particular, for each 1 mmHg increase in CO2, the odds of a crewmember reporting a headache doubled. For vision changes, 29 reports of vision changes were observed. These observations were not found to be statistically associated with CO2 levels as analyzed. While the incidence of headache has was not high (~3%), headaches may be an indicator of underlying increases in intracranial pressure, which may result likely from the synergy between CO2‐induced cerebral vasodilatation and decreased venous drainage in microgravity. Vision changes were inconsistently reported and as a result did not align appropriately with the CO2 levels. Further analysis is needed. Our results support ongoing efforts to lower the CO2 exposure limits in spacecraft.

VanBaalen, M.

Missing Data and Multiple Imputation: An Unbiased Approach

The default method of dealing with missing data in statistical analyses is to only use the complete observations (complete case analysis), which can lead to unexpected bias when data do not meet the assumption of missing completely at random (MCAR). For the assumption of MCAR to be met, missingness cannot be related to either the observed or unobserved variables. A less stringent assumption, missing at random (MAR), requires that missingness not be associated with the value of the missing variable itself, but can be associated with the other observed variables. When data are truly MAR as opposed to MCAR, the default complete case analysis method can lead to biased results. There are statistical options available to adjust for data that are MAR, including multiple imputation (MI) which is consistent and efficient at estimating effects. Multiple imputation uses informing variables to determine statistical distributions for each piece of missing data. Then multiple datasets are created by randomly drawing on the distributions for each piece of missing data. Since MI is efficient, only a limited number, usually less than 20, of imputed datasets are required to get stable estimates. Each imputed dataset is analyzed using standard statistical techniques, and then results are combined to get overall estimates of effect. A simulation study will be demonstrated to show the results of using the default complete case analysis, and MI in a linear regression of MCAR and MAR simulated data. Further, MI was successfully applied to the association study of CO2 levels and headaches when initial analysis showed there may be an underlying association between missing CO2 levels and reported headaches. Through MI, we were able to show that there is a strong association between average CO2 levels and the risk of headaches. Each unit increase in CO2 (mmHg) resulted in a doubling in the odds of reported headaches.

Foy, M.

Challenges in Evaluating Relationships Between Quantitative Data (Carbon Dioxide) and Qualitative Data (Self-Reported Visual Changes)

Understanding the nuances in clinical data is critical in developing a successful data analysis plan. Carbon dioxide (CO2) data are collected on board the International Space Station (ISS) in a continuous stream. Clinical data on ISS are primarily collected via conversations between individual crewmembers and NASA Flight Surgeons during weekly Private Medical Conferences (PMC). Law, et.al, 20141 demonstrated a statistically significant association between weekly average CO2 levels on ISS and self-reported headaches over the reporting period from March 14, 2001 to May 31, 2012. The purpose of this analysis is to describe the evaluation of a possible association between visual changes and CO2 levels on ISS and to discuss challenges in developing an appropriate analysis plan. METHODS & PRELIMINARY RESULTS: A first analysis was conducted following the same study design as the published work on CO2 and self-reported headaches1; substituting self-reported changes in visual acuity in place of self-reported headaches. The analysis demonstrated no statistically significant association between visual impairment characterized by vision symptoms self-reported during PMCs and ISS average CO2 levels over ISS missions. Closer review of the PMC records showed that vision outcomes are not well-documented in terms of clinical severity, timing of onset, or timing of resolution, perhaps due to the incipient nature of vision changes. Vision has been monitored in ISS crewmembers, pre- and post-flight, using standard optometry evaluations. In-flight visual assessments were limited early in the ISS program, primarily consisting of self-perceived changes reported by crewmembers. Recently, on-orbit capabilities have greatly improved. Vision data ranges from self-reported post-flight changes in visual acuity, pre- to postflight changes identified during fundoscopic examination, and in-flight progression measured by advanced on-orbit clinical imaging capabilities at predetermined testing intervals. In contrast, CO2 data are recorded in a continuous stream over time; however, for the initial analysis this data was categorized into weekly averages.

Mendez, C. M.

Linear arrays of InGaAs/InP avalanche photodiodes for 1.0-1.7 micron

Separate absorption and multiplication InGaAs/InP avalanche photodiodes (SAM-APDs) with a floating guard ring structure that is well-suited to array applications have been successfully demonstrated. Individual APDs have breakdown voltages greater than 80 V, multiplications over 40 at 100 nA dark current, and uniform spatial gain profiles. Uniform I-V characteristics and gains have been measured over linear dimensions as large as 1.2 cm. Gains over 10 at low multiplied dark currents were measured on 21 consecutive devices at the wafer level.

Ackley, D. E.

Infrared spectra and interstellar reddening of anonymous type II OH/IR stars

Infrared positions and multicolor infrared photometry for a sample of type II OH/IR stars are reported. The infrared colors and 11.4-micron silicate optical depths of the confirmed sources in this group increase as a function of distance, suggesting that interstellar reddening must be taken into account in assessing their infrared energy distributions and physical characteristics.

Gehrz, R. D.