Engineering Papers⌕ Search

Engineering topics

Martino, A.

Publications and source records attributed to Martino, A..

The Wide-Field Imaging Interferometry Testbed: Progress and Plans

We describe the technique of wide field mosaic imaging for optical/IR interferometers and present early experimental results from a laboratory instrument designed to validate, experiment with, and refine the technique. A conventional single-detector stellar interferometer operating with narrow bandwidth at center wavelength lambda is limited in its field of view to the primary beam of the individual telescope apertures, or approx. lambda/D(sub tel) radians, where is the telescope diameter. Such a field is too small for many applications; often one wishes to image extended sources. We are developing and testing a technique analogous to the mosaic method employed in millimeter and radio astronomy, but applicable to optical/IR Michelson interferometers, in which beam combination is done in the pupil plane. An N(sub pix) x N(sub pix) detector array placed in the image plane of the interferometer is used to record simultaneously the fringe patterns from many contiguous telescope fields, effectively multiplying the field size by N(sub pix)/2, where the factor 2 allows for Nyquist sampling. This mosaic imaging technique will be especially valuable for far IR and submillimeter interferometric space observatories such as the Space Infrared Interferometric Telescope (SPIRIT) and the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). SPIRIT and SPECS will be designed to provide sensitive, high angular resolution observations of fields several arcminutes in diameter, and views of the universe complementary to those provided by HST, NGST, and ALMA.

Rinehart, S. A.↗

Acquisition and tracking performance measurements for a high speed area array detector system

A proof-of-concept (POC) demonstration system has been developed which demonstrates acquisition, tracking and point-ahead angle sensing for a space optical communications terminal utilizing a single high speed area array detector. The detector is the 128 x 128 pixel Kodak HS-40 photodiode array. It has 64 parallel readout channels and can operate at frames rates up to 40,000 frames/sec with rms readout noise of 20 photoelectrons. A windowing scheme and special purpose digital signal processing electronics are employed to implement acquisition and tracking algorithms. The system operates at greater than 1 kHz sample (frame) rates. Acquisition can be performed in as little as 30 milliseconds with less than 1 picowatt of 0.85 micron beacon power on the detector. At the same power level, the rms tracking accuracy is approximately 1/16 pixel. Results of system analysis and measurements using the POC system are presented.

Short, R. C.↗