Engineering Papers⌕ Search

Engineering topics

Martineau, Richard Charles

Publications and source records attributed to Martineau, Richard Charles.

BIGHORN Computational Fluid Dynamics Theory, Methodology, and Code Verification & Validation Benchmark Problems

This document presents the theoretical background for a hybrid finite-element / finite-volume fluid flow solver, namely BIGHORN, based on the Multiphysics Object Oriented Simulation Environment (MOOSE) computational framework developed at the Idaho National Laboratory (INL). An overview of the numerical methods used in BIGHORN are discussed and followed by a presentation of the formulation details. The document begins with the governing equations for the compressible fluid flow, with an outline of the requisite constitutive relations. A second-order finite volume method used for solving the compressible fluid flow problems is presented next. A Pressure-Corrected Implicit Continuous-fluid Eulerian (PCICE) formulation for time integration is also presented. The multi-fluid formulation is being developed. Although multi-fluid is not fully-developed, BIGHORN has been designed to handle multi-fluid problems. Due to the flexibility in the underlying MOOSE framework, BIGHORN is quite extensible, and can accommodate both multi-species and multi-phase formulations. This document also presents a suite of verification & validation benchmark test problems for BIGHORN. The intent for this suite of problems is to provide baseline comparison data that demonstrates the performance of the BIGHORN solution methods on problems that vary in complexity from laminar to turbulent flows. Wherever possible, some form of solution verification has been attempted to identify sensitivities in the solution methods, and suggest best practices when using BIGHORN.

97 MATHEMATICS AND COMPUTING↗

Analysis of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

Determination of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

RELAP-7 Theory Manual

This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Demonstration of Advanced Safety Analysis Tools and Methods Applied to Large Break LOCA and Fuel Analysis for PWRs

The U.S. Nuclear Regulatory Commission (NRC) is currently proposing a rulemaking designated as 10 CFR 50.46c to revise the loss-of-coolant accident (LOCA)/emergency core cooling system acceptance criteria to include the effects of higher burnup on fuel/cladding performance. We propose a demonstration problem of a representative four-loop PWR plant to study the impact of this new rule in the US nuclear fleet. Within the scope of evaluation for the 10 CFR 50.46c rule, aspects of safety, operations, and economics are considered in the industry application demonstration presented in this paper. An advanced safety analysis approach is used, by integrating the probabilistic element with deterministic methods for LOCA analysis, a novel approach to solving these types of multi-physics, multi-scale problems.

LOCA RIMM RISMC RELAP-7↗

IMPLEMENTATION AND VALIDATION OF A FULLY IMPLICIT ACCUMULATOR MODEL IN RELAP-7

This paper presents the implementation and validation of an accumulator model in RELAP-7 under the framework of preconditioned Jacobian free Newton Krylov (JFNK) method, based on the similar model used in RELAP5. RELAP-7 is a new nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 is a fully implicit system code. The JFNK and preconditioning methods used in RELAP-7 is briefly discussed. The slightly modified accumulator model is summarized for completeness. The implemented model was validated with LOFT L3-1 test and benchmarked with RELAP5 results. RELAP-7 and RELAP5 had almost identical results for the accumulator gas pressure and water level, although there were some minor difference in other parameters such as accumulator gas temperature and tank wall temperature. One advantage of the JFNK method is its easiness to maintain and modify models due to fully separation of numerical methods from physical models. It would be straightforward to extend the current RELAP-7 accumulator model to simulate the advanced accumulator design.

Accumulator↗

RELAP-7 Development Updates

RELAP-7 is a nuclear systems safety analysis code being developed at the Idaho National Laboratory, and is the next generation tool in the RELAP reactor safety/systems analysis application series. RELAP-7 development began in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway of the Light Water Reactor Sustainability (LWRS) program. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support nuclear power safety analysis. The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). The initial development goal of the RELAP-7 approach focused primarily on the development of an implicit algorithm capable of strong (nonlinear) coupling of the dependent hydrodynamic variables contained in the 1-D/2-D flow models with the various 0-D system reactor components that compose various boiling water reactor (BWR) and pressurized water reactor nuclear power plants (NPPs). During Fiscal Year (FY) 2015, the RELAP-7 code has been further improved with expanded capability to support boiling water reactor (BWR) and pressurized water reactor NPPs analysis. The accumulator model has been developed. The code has also been coupled with other MOOSE-based applications such as neutronics code RattleSnake and fuel performance code BISON to perform multiphysics analysis. A major design requirement for the implicit algorithm in RELAP-7 is that it is capable of second-order discretization accuracy in both space and time, which eliminates the traditional first-order approximation errors. The second-order temporal is achieved by a second-order backward temporal difference, and the one-dimensional second-order accurate spatial discretization is achieved with the Galerkin approximation of Lagrange finite elements. During FY-2015, we have done numerical verification work to verify that the RELAP-7 code indeed achieves 2nd-order accuracy in both time and space for single phase models at the system level.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convergence study of Rattlesnake solutions for the two-dimensional C5G7 MOX benchmark

This paper presents the convergence study of a specific transport scheme, self-adjoint angular flux (SAAF) formulation with the discrete ordinates (SN) method and continuous finite element method (CFEM), implemented with Rattlesnake, on solving the well known two-dimensional C5G7 MOX benchmark. Both the convergence in space and angle are studied. Numerical results show the convergence of the spatial and angular refinements.

Benchmark↗

RELAP-7 Theory Manual

This document summarizes the physical models and mathematical formulations used in the RELAP-7 code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES

The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoid overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety system components such as the safety relief valve (SRV), the RCIC system, the wet well, and the dry well. The results show reasonable system behaviors while exhibiting rich dynamics such as variable flow rates through RCIC turbine and pump during the SBO transient. The model has the potential to resolve the Fukushima RCIC mystery after adding the off-design two-phase turbine operation model and other additional improvements.

RCIC↗

RELAP-7 User's Guide

The document contains a user's guide on how to run the RELAP-7 code. The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory. RELAP-7 will become the main reactor systems simulation toolkit for the LWRS (Light Water Reactor Sustainability) program’s RISMC (Risk Informed Safety Margin Characterization) effort and the next generation tool in the RELAP reactor safety/systems analysis application series. RELAP-7 is written with object oriented programming language C++. A number of example problems and their associated input files are presented in this document to guide users to run the RELAP-7 code starting with simple pipe problems to problems with increasing complexity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗