Engineering Papers⌕ Search

Engineering topics

Martindale, W. R.

Publications and source records attributed to Martindale, W. R..

22 records · Page 2

Experimental and theoretical aerodynamic heating and flow field analysis of a space shuttle orbiter

The results of work on the McDonnell Douglas delta wing orbiter are summarized and compared to other data and theories where applicable. The tests were conducted in the continuous hypersonic Tunnel B at Mach 8 and in the hypervelocity hotshot Tunnel F at Mach 10.5. Photographic data are used to illustrate the regions of peak heating on the lee-side and to show the vortical nature of the flow. Windward centerline data include measurements of shock angle, surface pressure, flow field pitot pressure and total temperature, and heat transfer rate coefficient distributions. Shock angles, surface pressures, and local Mach number distributions are compared with tangent cone theory over an angle of attack range from 10 to 60 deg. The measured heat transfer rate coefficient distributions are compared to both laminar and turbulent theories and boundary layer transition data are compared to the McDonnell Douglas criteria.

Matthews, R. K.↗

Space shuttle: Heat transfer rate measurements of North American Rockwell orbiter (161B) at nominal Mach number of 8

Plots and tables which determine detailed heat transfer distributions on phase B space shuttle configurations are presented. A thin-skinned thermocouple was used to measure the reentry events of the delta wing orbiter. Data was obtained at a nominal Mach number of 8 and free stream Reynolds numbers ranging from 0.83 x 10 to the 6th power to 3.76 x 10 to the 6th power per foot. Angle of attack was varied from -5 to 50 degrees.

Warmbrod, J. D.↗

Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) and North American Rockwell orbiter (161B) at nominal Mach number of 8

Plotted and tabulated data from the thin-skin thermocouple phase of an experimental test program are presented. These data are representative of three events of simulated flight and are described as booster-orbiter ascent heating data, booster reentry heating data, and orbiter reentry heating data. The test was conducted in a 50-inch hypersonic tunnel b at a nominal Mach number of 8 and free-stream Reynolds number range of 700,000 to 3,700,000 per foot. The model employed was a 0.009 scale replica of the Convair B-15B-2 booster and North American Rockwell 161B orbiter.

Warmbrod, J. D.↗

Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) at nominal Mach number of 8

Plotted and tabulated data on heat transfer from a thin-skin thermocouple are presented. The data is representative of the reentry event of the booster alone configuration. The data were generated during wind tunnel tests of the B-15B-2 delta wing booster at Mach 8. Thermocouple measurements are reduced to heat transfer coefficient ratio and the data are presented as plotted variations versus longitudinal, lateral, and vertical local model positions.

Warmbrod, J. D.↗