Engineering Papers⌕ Search

Engineering topics

Martin, R. B.

Publications and source records attributed to Martin, R. B..

Effects of chair restraint on the strength of the tibia in rhesus monkeys

To determine the effects of the relative inactivity and unloading on the strength of the tibias of monkeys, Macaca mulatta, we used a non-invasive test to measure bending stiffness, or EI (Nm2), a mechanical property. The technique was validated by comparisons of in vivo measurements with standard measures of EI in the same bones post-mortem (r2 = 0.95, P < 0.0001). Inter-test precision was 4.28+/-1.4%. Normative data in 24 monkeys, 3.0+/-0.7 years and 3.6+/-0.6 kg, revealed EI to be 16% higher in the right than left tibia (4.4+/-1.6 vs. 3.7+/-1.6 Nm2, P < 0.05). Five monkeys, restrained in chairs for 14 days, showed decreases in EI. There were no changes in EI in two chaired monkeys that lost weight during a 2-week space flight. The factors that account for both the decreases in bone mechanical properties after chair restraint at 1 g and lack of change after microgravity remain to be identified. Metabolic factors associated with body weight changes are suggested by our results.

NASA Discipline Musculoskeletal↗

Noninvasive Determination of Bone Mechanical Properties using Vibration Response: A Refined Model and Validation in vivo

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical Response Tissue Analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(MRTA) and theoretical EI values for padded aluminum rods was R(exp 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal Bone Mineral Density (BMD) measurements were also made. The relationship between E(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(exp 2) = 0.947) and better than that using the older model (R(exp 2) = 0.645). EI(MRTA) and BMD are also highly correlated (R(exp 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(exp 2) = 0.915 and R(exp 2) = 0.894, respectively). This is the first biological validation of a non-invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Roberts, S. G.↗

Determinants of the mechanical properties of bones

The mechanical properties of bones are governed by the same principles as those of man-made load-bearing structures, but the organism is able to adapt its bone structure to changes in skeletal loading. In this overview of the determinants of the strength and stiffness of bone, a continuum approach has been taken, in which the behavior of a macroscopic structure depends on its shape and size, and on the mechanical properties of the material within. The latter are assumed to depend on the composition (porosity and mineralization) and organization (trabecular or cortical bone architecture, collagen fiber orientation, fatigue damage) of the bone. The effects of each of these factors are reviewed. Also, the possible means of non-invasively estimating the strength or other mechanical properties of a bone are reviewed, including quantitative computed tomography, photon absorptiometry, and ultrasonic measurements. The best estimates of strength have been obtained with photon absorptiometry and computed tomography, which at best are capable of accounting for 90% of the strength variability in a simple in vitro test, but results from different laboratories have been highly variable.

Non-NASA Center↗

Fragility and composition of growing rat bone after one week in spaceflight

To gain some insight into the early effects of spaceflight on skeletal metabolism, we quantified the major chemical constituents and a noncollagenous protein, osteocalcin, in the third-lumbar vertebrae and humeri from 8-wk-old rats that were part of the 7-day NASA Spacelab 3 flight experiments. The ratio of calcium to hydroxyproline in the humeral diaphysis increased from 8.5 in preflight to 9.8 in ground simulation control and only to 8.9 in flight bones. There was no demonstrable change in the fraction of nonmineralized collagen. Osteocalcin content was reduced in the humerus and vertebra. Reduced accumulation of mineral and osteocalcin with no associated decrease in collagen in flight animals suggests that both mineralization and collagen metabolism are impaired in growing animals during spaceflight within a few days after launch. Strength tests of the humeri of flight rats showed substantial deficits that appeared to be related, not only to the reduced bone mass, but also to the composition and quality of new bone formed.

STS-51B Shuttle Project↗

Osteocalcin as an indicator of bone metabolism during spaceflight

The effect of microgravity on osteocalcin (OC) is investigated in rats flown on Spacelab 3. Serum, Ca, Pi, total protein, alkaline phosphatase, and OC contents, and the breaking strength of the humerus of control and Spacelab rats are calculated; the procedures utilized for these analyses are described. It is detected that the OC is reduced, and the serum and alkaline phosphatase are unaffected by microgravity.

Patterson-Buckendahl, P. E.↗

Integrated atmosphere revitalization system description and test results

The design and operation of several air revitalization subsystems are described, along with the testing of these subsystems separately and integrated in an air revitalization system for use in space stations. The subsystems are: one that generates O2 by water electrolysis, one that removes and concentrates CO2 using an electrochemical technique, and one that reduces concentrated CO2 by the Sabatier process. Results of the integrated testing include the observations that liquid cooling should be baselined for recovery of the CO2 reduction subsystem product water, continuous CO2 injection into the air supply unit is preferable, small changes in the current CO2 removal subsystem inlet PCO2 are detectable as changes in the CO2 reduction subsystem reactor temperatures, and hardwired shutdown of critical parameters is vital if computer-based controllers are not redundant. Several block diagrams are provided.

Martin, R. B.↗

Sprayed Coating Renews Butyl Rubber

Damaged butyl rubber products are renewed by spray technique originally developed for protective suits worn by NASA workers. A commercial two-part adhesive is mixed with Freon-113 (or equivalent) trichlorotrifluoroethane to obtain optimum viscosity for spraying. Mix is applied with an external-air-mix spray gun.

Martin, R. B.↗

Development status of a preprototype water electrolysis subsystem

A preprototype water electrolysis subsystem was designed and fabricated for NASA's advanced regenerative life support program. A solid polymer is used for the cell electrolyte. The electrolysis module has 12 cells that can generate 5.5 kg/day of oxygen for the metabolic requirements of three crewmembers, for cabin leakage, and for the oxygen and hydrogen required for carbon dioxide collection and reduction processes. The subsystem can be operated at a pressure between 276 and 2760 kN/sq m and in a continuous constant-current, cyclic, or standby mode. A microprocessor is used to aid in operating the subsystem. Sensors and controls provide fault detection and automatic shutdown. The results of development, demonstration, and parametric testing are presented. Modifications to enhance operation in an integrated and manned test are described. Prospective improvements for the electrolysis subsystem are discussed.

Martin, R. B.↗