SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance.

60 APPLIED LIFE SCIENCES↗

SU-E-I-24: Method for CT Automatic Exposure Control Verification

Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomex electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-25: A Dosimetric Comparison of Three-Dimension Conformal and Intensity-Modulated Radiation Therapy in Esophageal Cancer

Purpose: dosimetric comparison of 3DCRT and IMRT in 9 esophageal cancer. The aim of this paper is to know which of these two techniques is dosimetrically more favorable dosimetrically at both the CTV coverage and dose obtained in the relevant organs at risk, in this case, lungs and heart, as the spinal cord received in all cases below 45 Gy. Methods: we chose 9 patients from our center (CHN) with the same type of esophageal cancer and in which the prescribed dose was the same, 54 Gy. For these treatments we have used the same fields and the same angles (AP (0 °), OPD (225°–240°) and OPI (125°–135°)).All plans have been implemented using Eclipse (version 11.0) with AAA( Analytical Anisotropic Algorithm )(Version 11.0.31). Results: To analyze the coverage of the CTV, we have evaluated the D99% and found that the average dose received by 99% of CTV with IMRT is 53.8 ± 0.4 Gy (99.6% of the prescribed dose) and the mean value obtained with 3DCRT is 52.3 ± 0.6 Gy (96.8% of the prescribed dose).The last data analyzed was the D2% of PTV, a fact that gives us information on the maximum dose received by our PTV. D2% of the PTV for IMRT planning is 55.4 ± 0.4 Gy (102.6% of the prescribed dose) and with 3DCRT is 56.8 ± 0.7 Gy (105.2% of the prescribed dose).All parameters analyzed at risk organs (V30, V40, V45 and V50 for the case of heart and V5, V10, V15 and V20 for the case of the lungs) provide us irradiated volume percentages lower in IMRT than 3DCRT. Conclusion: IMRT provides a considerable improvement in the coverage of the CTV and the doses to organs at risk.

60 APPLIED LIFE SCIENCES↗

SU-E-T-485: In Vivo Dosimetry with EBT3 Radiochromic Films for TBI Treatments

Purpose: Total body irradiation (TBI) is a technique that requires special equipment to control “in vivo” the dose to the patient because it is a complex technique performed in extraordinary conditions. There are several devices to perform this task (diodes, TLDs, ionization chambers, MOSFET). In this paper we study the possibility of performing these measurements with radiochromic films EBT3 properly calibrated. This method has been compared to the PTW diodes system for TBI. Methods: Once made the TC to the patients, we measured different thicknesses of the relevant areas of the body (head, neck, chest with or without arms, umbilicus area, knees and ankles); for each of these thicknesses we measured dose rate (cGy / UM) in RW3 phantom, in TBI conditions, with ionization chamber in the center; in turn, the input diode and the output of each configuration is placed to assign dose to each set of diodes. Movie calibration is performed according to manufacturer’s recommendations but TBI conditions. The dose at the center of each thickness compared to a linear interpolation of the dose at the entrance and exit, resulting in an adequate approximation. Finally in each session for each patient put a piece of film (2×2 cm2) at the entrance and another at the exit in each area, obtaining these readings and interpolating the estimated center dose, as with the diodes. Results: These results show a greater homogeneity in the distribution for use with film and validate the use of the same for this task and, if necessary, to avoid purchasing diode group if they have not. Conclusion: By using radiochromic films for this technique gives us a proper calculation of the dose received by the patient in the absence of other methods, or gives us a second additional track that already used normally.

60 APPLIED LIFE SCIENCES↗

Laser Microperforated Biodegradable Microbial Polyhydroxyalkanoate Substrates for Tissue Repair Strategies: An Infrared Microspectroscopy Studey

Flexible and biodegradable film substrates prepared by solvent casting from poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBHV) solutions in chloroform were microperforated by ultraviolet laser ablation and subsequently characterized using infrared (IR) microspectroscopy and imaging techniques and scanning electron microscopy (SEM). Both transmission synchrotron IR microspectroscopy and attenuated total reflectance microspectroscopy measurements demonstrate variations in the polymer at the ablated pore rims, including evidence for changes in chemical structure and crystallinity. SEM results on microperforated PHBHV substrates after cell culture demonstrated that the physical and chemical changes observed in the biomaterial did not hinder cell migration through the pores.

36 MATERIALS SCIENCE↗

Picosecond carrier lifetimes in dilute GaInNAs grown on InP substrate

We study the carrier relaxation dynamics in Ga{sub 1-y}In{sub y} N{sub 0.03}As{sub 0.97} layers grown on InP substrate by molecular beam epitaxy. This dilute nitride semiconductor is a potential candidate for ultrafast components such as photoconductive terahertz devices driven at 1.55 {mu}m wavelength. Carrier lifetimes are measured by pump-probe experiments at 1550 nm wavelength and the shortest carrier lifetime is 2.6 ps under photoexcitation with {approx}4.2 {mu}J/cm{sup 2}. We observe two contributions in the differential transmittance decay. These contributions are discussed in terms of photocarrier recombination processes.

36 MATERIALS SCIENCE↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strongly enhanced incorporation of oxygen into barium titanate based multilayer ceramic capacitors using water vapor

The reoxidation of sintered BaTiO{sub 3}-based multilayer ceramic capacitors (MLCCs) is currently an empirically determined, but poorly understood, procedure. In this work, the incorporation of oxygen into BaTiO{sub 3}-based MLCCs has been studied by means of isotope exchange annealing ({sup 18}O{sub 2}/{sup 16}O{sub 2}, {sup 1}H{sub 2}{sup 18}O/{sup 1}H{sub 2}{sup 16}O or {sup 2}H{sub 2}{sup 16}O/{sup 1}H{sub 2}{sup 16}O) and subsequent determination of the isotope profiles in the solid by secondary ion mass spectrometry. Oxygen isotope profiles in the barium titanate dielectric can be described by a bulk diffusion coefficient D* and a surface exchange coefficient k*. The values obtained for k* indicate that oxygen incorporation from H{sub 2}O is much faster than from dry O{sub 2}; it thus plays the key role in the reoxidation process.

36 MATERIALS SCIENCE↗

On the ammonolysis of Ga{sub 2}O{sub 3}: An XRD, neutron diffraction and XAS investigation of the oxygen-rich part of the system Ga{sub 2}O{sub 3}-GaN

We investigated the ammonolysis of beta-Ga{sub 2}O{sub 3} at elevated temperatures by means of ex situ X-ray diffraction, ex situ neutron diffraction and in situ X-ray absorption spectroscopy. Within the detection limits of these methods, we can rule out the existence of a crystalline or amorphous oxynitride phase that is not derived from wurtzite-type GaN. No evidence for a beta-Ga{sub 2}O{sub 3} related oxynitride phase was found, and the nitrogen solubility in beta-Ga{sub 2}O{sub 3} was found to be below the detection limit of about 2-3 at% in the anionic sublattice. These findings were obtained by monitoring the anionic occupancy factors and the lattice parameters of the beta-Ga{sub 2}O{sub 3} phase obtained from total diffraction pattern refinement with the Rietveld method and by linear combination fitting of the X-ray absorption spectra that were recorded during the ammonolysis. - Graphical abstract: The ammonolysis of beta-Ga{sub 2}O{sub 3} powders forming GaN at temperatures of 600-780 deg. C was monitored by means of XRD, neutron diffraction and X-ray absorption spectroscopy in order to identify the possible intermediates and the solubility limit of nitrogen in the oxide lattice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Epitaxial growth and picosecond carrier dynamics of GaInAs/GaInNAs superlattices

We study GaInAs/GaInNAs superlattice structures grown on InP substrate as potential candidates for photoconductive terahertz devices or saturable absorbers working at 1.55 {mu}m wavelength. The N-rich GaInNAs layers are flat, with no three-dimensional islanding, and act as trapping layers where carriers can recombine rapidly. The carrier lifetime in GaInAs/GaInNAs superlattice was measured for various growth parameters using time-resolved differential transmission experiments at 1.55 {mu}m wavelength. The carrier lifetime is found to depend strongly on N content and can be reduced down to 3.8 ps for samples with 14% of N. The mechanisms involved in the capture process of photocarriers are discussed.

36 MATERIALS SCIENCE↗

A Comparison of Rapid-Scanning X-Ray Fluorescence Mapping And Magnetic Resonance Imaging to Localize Brain Iron Distribution

The clinical diagnosis of many neurodegenerative disorders relies primarily or exclusively on observed behaviors rather than measurable physical tests. One of the hallmarks of Alzheimer disease (AD) is the presence of amyloid-containing plaques associated with deposits of iron, copper and/or zinc. Work in other laboratories has shown that iron-rich plaques can be seen in the mouse brain in vivo with magnetic resonance imaging (MRI) using a high-field strength magnet but this iron cannot be visualized in humans using clinical magnets. To improve the interpretation of MRI, we correlated iron accumulation visualized by X-ray fluorescence spectroscopy, an element-specific technique with T1, T2, and susceptibility weighted MR (SWI) in a mouse model of AD. We show that SWI best shows areas of increased iron accumulation when compared to standard sequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms involved in HBr and Ar cure plasma treatments applied to 193 nm photoresists

In this article, we have performed detailed investigations of the 193 nm photoresist transformations after exposure to the so-called HBr and Ar plasma cure treatments using various characterization techniques (x-ray photoelectron spectroscopy, Fourier transformed infrared, Raman analyses, and ellipsometry). By using windows with different cutoff wavelengths patched on the photoresist film, the role of the plasma vacuum ultraviolet (VUV) light on the resist modifications is clearly outlined and distinguished from the role of radicals and ions from the plasma. The analyses reveal that both plasma cure treatments induce severe surface and bulk chemical modifications of the resist films. The synergistic effects of low energetic ion bombardment and VUV plasma light lead to surface graphitization or cross-linking (on the order of 10 nm), while the plasma VUV light (110-210 nm) is clearly identified as being responsible for ester and lactone group removal from the resist bulk. As the resist modification depth depends strongly on the wavelength penetration into the material, it is found that HBr plasma cure that emits near 160-170 nm can chemically modify the photoresist through its entire thickness (240 nm), while the impact of Ar plasmas emitting near 100 nm is more limited. In the case of HBr cure treatment, Raman and ellipsometry analyses reveal the formation of sp{sup 2} carbon atoms in the resist bulk, certainly thanks to hydrogen diffusion through the resist film assisted by the VUV plasma light.

36 MATERIALS SCIENCE↗

Suppression of High-p{sub T} Neutral Pion Production in Central Pb+Pb Collisions at {radical}(s{sub NN})=17.3 GeV Relative to p+C and p+Pb Collisions

Neutral pion transverse momentum spectra were measured in p+C and p+Pb collisions at {radical}(s{sub NN})=17.4 GeV at midrapidity (2.3 < or approx. {eta}{sub lab} < or approx. 3.0) over the range 0.7 < or approx. p{sub T} < or approx. 3.5 GeV/c. The spectra are compared to {pi}{sup 0} spectra measured in Pb+Pb collisions at {radical}(s{sub NN})=17.3 GeV in the same experiment. For a wide range of Pb+Pb centralities (N{sub part} < or approx. 300), the yield of {pi}{sup 0}'s with p{sub T} > or approx. 2 GeV/c is larger than or consistent with the p+C or p+Pb yields scaled with the number of nucleon-nucleon collisions (N{sub coll}), while for central Pb+Pb collisions with N{sub part} > or approx. 350, the {pi}{sup 0} yield is suppressed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗