Engineering PapersSearch

Engineering topics

Markham, Brian

Publications and source records attributed to Markham, Brian.

25 records · Page 2

Landsat 4 Thematic Mapper Calibration Update

The Landsat-4 Thematic Mapper collected imagery of the Earth's surface from 1982 to 1993. Although largely overshadowed by Landsat 5, which was launched in 1984, Landsat 4 TM imagery extends the Thematic Mapper-based record of the Earth back to 1982 and also substantially supplements the image archive collected by Landsat 5. To provide a consistent calibration record for the TM instruments, Landsat 4 TM was cross-calibrated to Landsat 5 using nearly simultaneous overpass imagery of pseudo-invariant calibration sites (PICS) in the time period of 1988 through 1990. To determine if the radiometric gain of Landsat 4 had changed over its lifetime, time series from two PICS locations, a Saharan site known as Libya 4 and a site in southwest North America, commonly referred to as the Sonoran Desert PICS, were developed. Results indicated that Landsat 4 had been very stable over its lifetime with no discernible degradation in sensor performance in all the reflective bands except band 1. In contrast, band 1 exhibited a 12% decay in responsivity over the lifetime of the instrument. Results from this work have been implemented at USGS EROS, which enables users of Landsat TM data sets to obtain consistently calibrated data from Landsat 4 and 5 TM as well as Landsat 7 ETM+ instruments.

Helder, Dennis

Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

Markham, Brian

Advanced Land Imager Assessment System

The Advanced Land Imager Assessment System (ALIAS) supports radiometric and geometric image processing for the Advanced Land Imager (ALI) instrument onboard NASA s Earth Observing-1 (EO-1) satellite. ALIAS consists of two processing subsystems for radiometric and geometric processing of the ALI s multispectral imagery. The radiometric processing subsystem characterizes and corrects, where possible, radiometric qualities including: coherent, impulse; and random noise; signal-to-noise ratios (SNRs); detector operability; gain; bias; saturation levels; striping and banding; and the stability of detector performance. The geometric processing subsystem and analysis capabilities support sensor alignment calibrations, sensor chip assembly (SCA)-to-SCA alignments and band-to-band alignment; and perform geodetic accuracy assessments, modulation transfer function (MTF) characterizations, and image-to-image characterizations. ALIAS also characterizes and corrects band-toband registration, and performs systematic precision and terrain correction of ALI images. This system can geometrically correct, and automatically mosaic, the SCA image strips into a seamless, map-projected image. This system provides a large database, which enables bulk trending for all ALI image data and significant instrument telemetry. Bulk trending consists of two functions: Housekeeping Processing and Bulk Radiometric Processing. The Housekeeping function pulls telemetry and temperature information from the instrument housekeeping files and writes this information to a database for trending. The Bulk Radiometric Processing function writes statistical information from the dark data acquired before and after the Earth imagery and the lamp data to the database for trending. This allows for multi-scene statistical analyses.

Chander, Gyanesh

Parameters Describing Earth Observing Remote Sensing Systems

The Earth science community needs to generate consistent and standard definitions for spatial, spectral, radiometric, and geometric properties describing passive electro-optical Earth observing sensors and their products. The parameters used to describe sensors and to describe their products are often confused. In some cases, parameters for a sensor and for its products are identical; in other cases, these parameters vary widely. Sensor parameters are bound by the fundamental performance of a system, while product parameters describe what is available to the end user. Products are often resampled, edge sharpened, pan-sharpened, or compressed, and can differ drastically from the intrinsic data acquired by the sensor. Because detailed sensor performance information may not be readily available to an international science community, standardization of product parameters is of primary performance. Spatial product parameters described include Modulation Transfer Function (MTF), point spread function, line spread function, edge response, stray light, edge sharpening, aliasing, ringing, and compression effects. Spectral product parameters discussed include full width half maximum, ripple, slope edge, and out-of-band rejection. Radiometric product properties discussed include relative and absolute radiometry, noise equivalent spectral radiance, noise equivalent temperature diffenence, and signal-to-noise ratio. Geometric product properties discussed include geopositional accuracy expressed as CE90, LE90, and root mean square error. Correlated properties discussed include such parameters as band-to-band registration, which is both a spectral and a spatial property. In addition, the proliferation of staring and pushbroom sensor architectures requires new parameters to describe artifacts that are different from traditional cross-track system artifacts. A better understanding of how various system parameters affect product performance is also needed to better ascertain the utility of existing datasets and products as well as to specify the performance of new sensors and products. Examples of simulations performed for the Landsat Data Continuity Mission illustrate how various parameters affect system and product performance. Specific examples include the effects of ground sample distance, MTF, and band-to-band registration on various products.

Zanoni, Vicki

First Look at Landsat-7 Mission Performance: Technical and Operational Results to Date

A primary goal of the current Landsat-7 mission, launched on April 15, 1999, is to acquire and refresh on a seasonal basis, calibrated ata sets of multispectral digital imagery of the landmass of the Earth The Enhanced Thematic Mapper Plus (ETM+) imager flown on Landsat-7 provides ground spatial resolutions in the panchromatic, reflective and emissive bands of 15, 30 and 60 meters, respectively, for a nominal scene 183 km wide by 170 km long. This mission not only builds on the invaluable 27-year continuous archive of thematic images of the Earth provided by previous Landsat satellites, it also inaugurates a new era of robust data acquisition with an emphasis on global change science. The newly developed Long Term Acquisition Plan (LTAP) is being used to optimize the systematic collection of data from all parts of the globe, populating the U.S.-held archive at the USGS EROS Data Center (EDC) with over 90,000 Landsat scene per year . An additional 73,000 Images are expected to be acquired each year by several international ground stations, for a total downlink of Landsat7 data in excess of 100 terabytes per year. Nearly 20,000 scan of Landsat-7 ETM+ data have already been acquired in the first 100 days of the mission. Early results derived from assessments of the ETM+ instrument, the spacecraft, and the ground processing systems indicate that the image quality is outstanding, clearly the best ever provided by any Landsat mission. Sensor radiometric background stability after the first 100 days in orbit is approximately 0.1 percent. Stability of the Full Aperture Solar Calibrator is approximately 0.3 percent, and mid-scale per pixel noise is approximately 0.6 percent. A ground processing system has been implemented at EDC which is capable of capturing, processing and archiving 250 Landsat scenes 9 per day, and delivering 100 scene products to seems each day. The cost of a systematically-processed Level 1 product has been dropped dramatically to $600, end there is no longer any copyright protection an the data. The net result is that the use of Landsat ETM+ data is expected to grow dramatically, and this growth is expected to benefit all facets of the land remote sensing community.

Williams, Darrel L.

Aerosol optical depth retrievals over the Konza Prairie

The aerosol optical depth over the Konza Prairie, near Manhattan, Kansas, was recorded at various locations by five separate teams. These measurements were made in support of the First ISLSCP Field Experiment (FIFE) and used to correct imagery from a variety of satellite and aircraft sensors for the effects of atmospheric scattering and absorption. The results from one instrument are reported here for 26 days in 1987 and for 7 in 1989. Daily averages span a range of 0.05 to 0.28 in the midvisible wavelengths. In addition, diurnal variations are noted in which the afternoon optical depths are greater than those of the morning by as much as 0.07. A comparison between instruments and processing techniques used to determine these aerosol optical depths is provided. The first comparisons are made using summer 1987 data. Differences of as much as 0.05 (midvisible) are observed. Although these data allow reasonable surface reflectance retrievals, they do not agree to within the performance limits typically associated with these types of instruments. With an accuracy goal of 0.02 a preseason calibration/comparison experiment was conducted at a mountain site prior to the final field campaign in 1989. Good calibration data were obtained, and good agreement (0.01, midvisible) was observed in the retrieved optical depth acquired over the Konza. By comparing data from the surface instruments at different locations, spatial inhomogeneities are determined. Then, data from the airborne tracking sunphotometer allow one to determine variations as a function of altitude. Finally, a technique is proposed for using the in situ data to establish an instrument calibration.

Bruegge, Carol J.