Engineering Papers⌕ Search

Engineering topics

Markert, T. H.

Publications and source records attributed to Markert, T. H..

At least 19 records

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗

Proportional counter windows for the Bragg Crystal Spectrometer on AXAF

A Bragg Crystal Spectrometer (BCS) using a gas flow proportional counter as its primary detector is among the instruments under development for AXAF. The BCS will employ windows of 1-micron-thick polyimide coated on both sides with 200 A of Al; this window composition, while X-ray transmitting, will leak gas at a lower rate than the polypropylene film-based windows formerly employed. Accounts are given of the results obtained with additional innovative X-ray window materials currently under development, including diamond and Si-enriched Si3N4.

Markert, T. H.↗

A comparison of three regions of Puppis A

High resolution X-ray spectral observations of Puppis A were performed with the FPCS on the Einstein Observatory at three regions of the remnant: the shock front, the bright eastern knot, and the interior. Plasma diagnostics of lines from OVII and OVIII constrain the values of electron temperature, ionization timescale, and hydrogen column density. Results of the diagnostics for these three regions are compared. A nonequilibrium analysis of previously published fluxes of oxygen lines shows that the interior has not yet reached ionization equilibrium.

Fischbach, K. F.↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

Transmission grating spectroscopy and the Advanced X-ray Astrophysics Facility (AXAF)

The use of transmission gratings with grazing-incidence telescopes in celestial X-ray astrononmy is reviewed. The basic properties of transmission grating spectrometers and the use of 'phased' gratings to enhance the diffraction efficiency are outlined. The fabrication of the gratings is examined, giving special attention to the AXAF High Energy Transmission Grating. The performance of finite-period thick gratings is briefly discussed, and the performance of the transmission grating spectrometers planned for SPECTROSAT and AXAF are examined.

Schattenburg, M. L.↗

The MIT spectroscopy investigations on AXAF and the study of supernova remnants

The MIT High Resolution X-Ray Spectroscopy experiment on the AXAF, which will study physical conditions in celestial sources by means of detailed measurements of emission and absorption features in their spectra, involves two complementary dispersive instruments: Bragg Crystal Spectrometer (BCS) and High Energy Transmission Grating (HETG). This paper discusses the principles of operation of BCS and HETG and the results that will be obtained by these instruments. Measurements of individual line strengths obtained by the AXAF spectrometers will allow the application of plasma diagnostic techniques to a study of the detailed physical conditions in celestial objects, particularly in the optically thin plasma of supernova remnants, which is particularly well suited to the application of plasma diagnostics.

Canizares, C. R.↗

High-resolution X-ray spectroscopic evidence of nonequilibrium conditions in the Cygnus Loop

High-resolution spectroscopic X-ray observations of a portion of the Cygnus Loop made with the Focal Plane Crystal Spectrometer aboard the Einstein Observatory are reported. Emission lines for O VII, O VIII, and Ne IX are measured, and upper limits are set to other transitions in O VII and O VIII. The detected emission line fluxes are consistent with emission from an equilibrium plasma with an electron temperature of about 3 x 10 to the 6th K, a value similar to that obtained by numerous previous observers. The absence of any O VII forbidden line emission strongly suggests that the emitting plasma is not in collisional ionization equilibrium. This is shown to be the case using several line diagnostics formed from the observed emission lines and a simple model describing the X-ray emission from an ionizing nonequilibrium plasma.

Vedder, P. W.↗

The Bragg crystal spectrometer for AXAF

The goal of MIT's high resolution X-ray spectrometry investigation on the Advanced X-ray Astrophysics Facility is to study the physical conditions in celestial sources by means of detailed measurements of their X-ray spectra. The investigation involves two complimentary dispersive instruments, a Bragg crystal spectrometer (BCS) and a high energy transmission grating spectrometer. Particular attention is given to the BCS which will be used to measure the strengths of individual lines from both point and extended objects in order to apply plasma diagnostic techniques to the study of cosmic X-ray sources.

Canizares, C. R.↗

Observations of four nearby galaxies with the Einstein Observatory

Four nearby galaxies, NGC 205, NGC 6822, the dwarf elliptical galaxy in Uras Major, and Maffei 1, were studied with the imaging instruments on the Einstein Observatory, and the results are reported. Fifteen X-ray sources were discovered, eight of which may not be associated with the target galaxies. No X-ray source was found in NGC 205, and one was found in NGC 6822, probably the optical supernova remnant Hodge 12. There are at most three sources in the Ursa Minor galaxy. There is probably an extended source associated with the Maffei 1 galaxy.

Markert, T. H.↗

High spectral resolution observations of the coronal X-ray emission from the RS CVn binary Sigma Corona Borealis

The results of high-resolution observations of the RS CVn binary star Rho Cr B are reported. The observations were carried out using the Focal Plane Crystal Spectrometer (FPCS) onboard the Einstein Observatory satellite. A spectral scan in the interval 800-840 eV shows clear evidence of an X-ray emission line at 826 eV identified with 1S(0)-1P(1) transition of Fe XVII. A prominent peak at 1007 eV in the scan band 986-1014 eV was attributed to a blend of lines produced by highly ionized iron. On the basis of the observed fluxes of the lines and the theoretical calculations of Raymond and Smith (1977), best-fit values of corona temperature and volume emission measures of 6.92 (+0.84 or -0.75) x 10 to the 6th K, and 1.74 (+0.55 or -0.69) x 10 to the 35th are derived, respectively. Some implications of the results are briefly discussed.

Agrawal, P. C.↗

X-ray observations of M33 with the high resolution imager on the Einstein Observatory

Three observations, separated by 6 months, of the Local Group galaxy M33 using the high resolution imager (HRI) on the Einstein Observatory are reported. Eight X-ray sources with luminosites ranging from 8 x 10 to the 36th to 1.2 x 10 to the 39th ergs/s have been detected. For seven of these sources, finding charts with positions accurate to less than 5 arcsec are provided. The X-ray properties and possible identifications are discussed for the eight HRI-detected sources and for two other sources, previously described by Long et al. (1981), for which upper limits are provided. It is found that most of the sources are associated with Population I markers. One source may be coincident with an optical supernova remnant. The most luminous source (by a factor of at least 25) is that associated with the optical nucleus. Because the X-ray flux from the nucleus decreased by a factor of 1/2 between the first and second observations, it is most likely that a single, compact object is responsible for the X-ray emission. It is possible that this source may be an active galactic nucleus, a massive binary X-ray source, or a low-mass X-ray binary such as are found in globular clusters within the Galaxy.

Markert, T. H.↗

X-ray spectroscopy of the galaxy M87 - Radiative accretion of the hot plasma halo

Canizares et al. (1979) have reported the detection of the O VIII Lyman-alpha line from the vicinity of the giant elliptical galaxy M87 in the Virgo cluster. The detection is based on high-resolution X-ray spectroscopy studies performed with the Focal Plane Crystal Spectrometer on the Einstein Observatory. The presence of a strong O VIII line indicates the existence of some material which is cooler than the bulk of the X-ray emitting gas surrounding M87. The result is interpreted as favoring models which call for radiative accretion of the hot gas onto M87. The present investigation is concerned with further high-resolution X-ray spectroscopy of M87. Seven additional emission line blends due primarily to ionized iron have been detected. These data make it possible to derive the approximate distribution of the quantity of emitting material over more than a decade in temperature for the central part of the M87 source. The obtained results are in excellent agreement with expectations for radiative, pressure driven accretion.

Canizares, C. R.↗

X-ray spectroscopy and imagery of supernova remnants with the Einstein Observatory

The two complementary spectroscopic instruments of the Einsten Observatory make possible X-ray spectroscopy of SNRs with considerably increased sensitivity and spectral resolution. The Solid State Spectrometer is a cryogenically cooled detector with 160 eV resolution, which suffices not only for the separation of lines due to different elements, but also the resolution of H-like, He-like and neutral lines from the same element for Si and above. The Focal Plane Crystal Spectrometer uses Bragg crystals to achieve excellent spectral resolution, but at the expense of sensitivity. Both instruments operate over most of the 0.2-4 keV energy band of the Einstein telescope, and are able to detect most of the important X-ray lines except the K lines of Fe and Ni.

Winkler, P. F.↗

Two X-ray supernova remnants - G296.1 - 0.7 and 1E 1149.4 - 6209

Using the imaging X-ray detectors on the Einstein Observatory, what appear to be two overlapping galactic supernova remnants are discovered, one of which is clearly identified with the previously cataloged radio remnant G296.1-0.7. The other feature has no radio or optical counterpart. It is a nearly complete ring with a diameter of 20-25 arcmin, designated 1E 1149.4-6209. Because of its morphology, because there is evidence for supernova events in the vicinity, and because there seems to be no plausible alternative, 1E 1149.4-6209 is classified as a supernova remnant. This remnant and others like it, which may be found first in X-rays rather than radio or optical waves, may have important implications regarding the evolution of supernova remnants and the rate of supernovae in our Galaxy.

Markert, T. H.↗

A survey of X-ray line emission from the supernova remnant Puppis A

Initial results from the first high-resolution study of the X-ray spectrum of a supernova remnant are reported. The spectrum of Puppis A between 500 and 1100 eV has been surveyed with the Focal Plane Crystal Spectrometer on the Einstein Observatory and the flux in eight lines and three line blends from various transitions of highly ionized nitrogen, oxygen, neon, and iron has been measured. The spectrum resembles that of active regions in the solar corona, but the neon lines seem enhanced relative to the oxygen lines, and both are enhanced relative to iron. The observed line strengths serve as diagnostics of the physical conditions in the emitting material. Without a priori assumptions, the ionization temperatures of O (2.2 million K) and Ne (4 million K) and the dominant ionization stage of Fe (Fe XVII) are deduced. Isothermal equilibrium plasmas or homogeneous nonequilibrium plasmas as descriptions of the source are ruled out. It is concluded that Puppis A must contain plasma over a temperature range 2-million to 5-million K with an intervening absorption column of 4 x 10 to the 21st/sq cm.

Winkler, P. F.↗

X-ray line emission from the Puppis A supernova remnant - Oxygen lines

Six prominent X-ray emission lines of O VII and O VIII have been detected from a portion of the Puppis A supernova remnant in observations with the Einstein Observatory Focal Plane Crystal Spectrometer. The lines are sufficiently well resolved to serve as diagnostics of the emitting plasma. From the relative intensities of the lines, it is inferred that the population of O VIII is about 1.5 times that of O VII, and that electron collisions are the dominant excitation mechanism in the plasma. A locus of allowed electron temperatures and interstellar-absorption column densities is derived: 1.5 x 10 to the 6th K, and (2-6) x 10 to the 21st per sq cm. The data are consistent with either a thin plasma source in equilibrium at a temperature of 2.2 x 10 to the 6th K with a column density of 4 x 10 to the 21st per sq cm, or with a nonequilibrium source in which the electrons have been shock-heated to a higher temperature and oxygen is underionized.

Winkler, P. F.↗

X-ray emission from supernova remnants near gamma-ray sources

It is noted that the imaging proportional of the Einstein Observatory has been used to search for X-ray emission from eight radio supernova remnants which are near three of the Cos-B unidentified gamma-ray sources: 2CG 311-01, CG 327-0, and CG 333+0. Emissions are observed from three of the remnants and upper limits on the remainder which are consistent with the luminosity expected from a simple blast-wave heated plasma model of the process. Thus none of the remnants are superluminous as might be expected if the pattern of the Crab Nebula were followed. It is thought that the remnant RCW 103 may be Vela-like. It is noted that another of the remnants, Kes 27, has centrally peaked X-ray emission which is unlike the shell-like emission seen for many remnants and which does not correlate well with its asymmetric radio emission.

Lamb, R. C.↗