Engineering Papers⌕ Search

Engineering topics

Marinelli, W. J.

Publications and source records attributed to Marinelli, W. J..

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

Contamination detection NDE for cleaning process inspection

In the joining of multilayer materials, and in welding, the cleanliness of the joining surface may play a large role in the quality of the resulting bond. No non-intrusive techniques are currently available for the rapid measurement of contamination on large or irregularly shaped structures prior to the joining process. An innovative technique for the measurement of contaminant levels in these structures using laser based imaging is presented. The approach uses an ultraviolet excimer laser to illuminate large and/or irregular surface areas. The UV light induces fluorescence and is scattered from the contaminants. The illuminated area is viewed by an image-intensified CCD (charge coupled device) camera interfaced to a PC-based computer. The camera measures the fluorescence and/or scattering from the contaminants for comparison with established standards. Single shot measurements of contamination levels are possible. Hence, the technique may be used for on-line NDE testing during manufacturing processes.

Marinelli, W. J.↗

Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

Kessler, W. J.↗

Arcing of negatively biased solar cells in a plasma environment. I - Experimental observations

A variety of experiments have been performed which identify key factors contributing to the arcing of negatively biased high voltage solar cells operating in a low earth orbit plasma environment. These efforts have led to a reduction of greater than a factor of 100 in the arc frequency of a single cells following proper remeditation procedures. Experiments naturally led to and focused on the adhesive/encapsulating that is used to bond the protective cover slip to the solar cell. An image-intensified CCD camera system recorded UV emission from arc events which occurred exclusively along the interfacial edge between the cover slip and the solar cell. Microscopic inspection of this interfacial region showed a bead of encapsulant along this entire edge. Elimination of this encapsulant bead reduced the arc frequency by two orders of magnitude.

Upschulte, B. L.↗

Studies of non-equilibrium radiation signatures behind hypersonic shock fronts

A new electric arc-driven shock tube facility is described. The radiative diagnostics include two optical multichannel analyzers, which can provide spectrally resolved snapshots of ultraviolet and visible shock fluorescence in both nonequilibrium and equilibrium regions behind the incident shock, as well as a bank of six filtered radiometers which allow temporal monitoring of key spectral features. Preliminary measurements of the radiative signatures behind low pressure shocks in air and nitrogen are presented for the shock velocity range of 6 to 12 km/s.

Donohue, K.↗

Solar cell arcing: The role of outgassing and contamination

The effect of outgassing, venting, and thruster firing events on spacecraft system performance has been a long standing issue. Recent laboratory measurements on negatively biased high voltage solar cells at Physical Sciences Inc. (PSI) suggest that some currently designed and certainly future space power systems must address/re-evaluate this issue. Our observations show that exposing these cells to moderate levels (10 exp -3 torr-min) of H2O vapor enhances the arcing frequency, while heating to 85 C to remove water vapor significantly reduces the arc frequency. The interaction of the adhesive used to attach the cover glass to the solar cell with ambient water vapor is the key factor in determining arcing rates. Elimination of adhesive exposed to the environmental plasma reduces the arc frequency more than two orders of magnitude, and eliminates any sensitivity to H2O exposure. The adhesive may also become a source of spacecraft contamination. Macroscopic amounts were observed to blow off some arc events, and (we assume) electrostatically precipitate at other negatively biased locations. Data, analysis, and potential impact for future space platforms are discussed.

Marinelli, W. J.↗

Arcing of negatively biased solar cells in low earth orbit

A set of experiments is described in which the arcing of negatively biased solar cells is examined and characterized in terms of the primary factors that cause such behavior. The experiments are conducted in an ultrahigh vacuum chamber, and an image-intensified CCD camera is employed to monitor UV emission from arc events at the interfacial edge between the cover slip and the solar cell. A bead of encapsulant along the interfacial edge is noted which can be removed to reduce arc frequency, and water contamination is found to further enhance arcing. Frequency of arcing is found to vary indirectly with temperature and directly with exposure to H2O, but no other significant correlations are noted. The sensitivity to H2O vapor is eliminated by simply removing the adhesive/encapsulant, and the corresponding arc-rate performance is low.

Upschulte, B. L.↗

Arcing in space structures in low Earth orbit

This report describes results of an experimental and theoretical program to investigate arcing of structures containing dielectric and conducting materials when they are biased negatively with respect to a plasma. An argon ion source generated Ar(+) ions of directed energy 20 to 40 eV and density approximately 10(exp 7) cm(exp -3) that impinged upon samples containing a dielectric material on top of a negatively biased Kovar plate. Arcing events were studied for bias voltages between -300 and -1000V with respect to the ion beam. The samples were Dow Corning 93-500 adhesive on Kovar, fused silica cover slips bonded on Kovar, and silicon solar cells mounted on Kovar. Measurements of discharge current, Kovar plate voltage, and radiation from the arc versus time were carried out. Microsecond duration exposure images and optical spectra in the 0.24 to 0.40 micron band were also acquired during arcing events. Arcing events were found to be associated with exposed adhesive and means were found to eliminate arcing altogether. The charging of a silica cover plate and the fields around the plate were calculated using a particle-in-cell code. Models were developed to explain the ignition of the arc and the physical processes occurring during the discharge.

Upschulte, B. L.↗

Aerothermodynamic radiation studies

We have built and made operational a 6 in. electric arc driven shock tube which alloys us to study the non-equilibrium radiation and kinetics of low pressure (0.1 to 1 torr) gases processed by 6 to 12 km/s shock waves. The diagnostic system allows simultaneous monitoring of shock radiation temporal histories by a bank of up to six radiometers, and spectral histories with two optical multi-channel analyzers. A data set of eight shots was assembled, comprising shocks in N2 and air at pressures between 0.1 and 1 torr and velocities of 6 to 12 km/s. Spectrally resolved data was taken in both the non-equilibrium and equilibrium shock regions on all shots. The present data appear to be the first spectrally resolved shock radiation measurements in N2 performed at 12 km/s. The data base was partially analyzed with salient features identified.

Donohue, K.↗

Significant reduction in arc frequency biased solar cells: Observations, diagnostics, and mitigation technique(s)

A variety of experiments were performed which identify key factors contributing to the arcing of negatively biased high voltage solar cells. These efforts have led to reduction of greater than a factor of 100 in the arc frequency of a single cell following proper remediation procedures. Experiments naturally lead to and focussed on the adhesive/encapsulant that is used to bond the protective cover slip to the solar cell. An image-intensified charge coupled device (CCD) camera system recorded UV emission from arc events which occurred exclusively along the interfacial edge between the cover slip and the solar cell. Microscopic inspection of this interfacial region showed a bead of encapsulant along this entire edge. Elimination of this encapsulant bead reduced the arc frequency by two orders of magnitude. Water contamination was also identified as a key contributor which enhances arcing of the encapsulant bead along the solar cell edge. Spectrally resolved measurements of the observable UV light shows a feature assignable to OH(A-X) electronic emission, which is common for water contaminated discharges. Experiments in which the solar cell temperature was raised to 85 C showed a reduced arcing frequency, suggesting desorption of H2O. Exposing the solar cell to water vapor was shown to increase the arcing frequency. Clean dry gases such as O2, N2, and Ar show no enhancement of the arcing rate. Elimination of the exposed encapsulant eliminates any measurable sensitivity to H2O vapor.

Upschulte, B. L.↗

Collisional quenching of atoms and molecules on spacecraft thermal protection surfaces

Preliminary results of a research program to determine energy partitioning in spacecraft thermal protection materials due to atom recombination at the gas-surface interface are presented. The primary focus of the research is to understand the catalytic processes which determine heat loading on Shuttle, Aeroassisted OTV, and NASP thermal protection surfaces in nonequilibrium flight regimes. Highly sensitive laser diagnostics based on laser-induced fluorescence and resonantly-enhanced multiphoton ionization spectroscopy are used to detect atoms and metastable molecules. At low temperatures, a discharge flow reactor is employed to measure deactivation/recombination coefficients for O-atoms, N-atoms, and O2. Detection methods are presented for measuring O-atoms, O2 and N2, and results for deactivation of O2 and O-atoms on reaction-cured glass and Ni surfaces. Both atom recombination and metastable product formation are examined. Radio-frequency discharges are used to produce highly dissociated beams of atomic species at energies characteristic of the surface temperature. Auger electron spectroscopy is employed as a diagnostic of surface composition in order to accurately define and control measurement conditions.

Marinelli, W. J.↗

Spectral identification/elimination of molecular species in spacecraft glow

Computer models of molecular electronic and vibrational emission intensities were developed. Known radiative emission rates (Einstein coefficients) permit the determination of relative excited state densities from spectral intensities. These codes were applied to the published spectra of glow above shuttle surface and to the Spacelab 1 results of Torr and Torr. The theoretical high-resolution spectra were convolved with the appropriate instrumental slit functions to allow accurate comparison with data. The published spacelab spectrum is complex but N2+ Meinel emission can be clearly identified in the ram spectrum. M2 First Positive emission does not correlate well with observed features, nor does the CN Red System. Spectral overlay comparisons are presented. The spectrum of glow above shuttle surfaces, in contrast to the ISO data, is not highly structured. Diatomic molecular emission was matched to the observed spectral shape. Source excitation mechanisms such as (oxygen atom)-(surface species) reaction product chemiluminescence, surface recombination, or resonance fluorescent re-emission will be discussed for each tentative assignment. These assignments are the necessary first analytical step toward mechanism identification. Different glow mechanisms will occur above surfaces under different orbital conditions.

Green, B. D.↗