Engineering PapersSearch

Engineering topics

Margolis, J. S.

Publications and source records attributed to Margolis, J. S..

At least 19 records

Atmospheric CO2 retrieved from ground-based solar spectra

The column-averaged volume mixing ration of CO2 over Kitt Peak, Arizona, has been retrieved from high-resolution solar absorption spectra obtained with the fourier transform spectrometer on the McMath telescope.

infrared remote sensing

Hydrazine Detection with a Tunable Diode Laser Spectrometer

Several instruments have been developed to measure low concentrations of hydrazine but none completely meet the sensitivity requirements while satisfying additional criteria such as quick response, stable calibration, interference free operation, online operation, reasonable cost, etc. A brief review is presented of the current technology including the electrochemical cell, the ion mobility spectrometer, the mass spectrometer, and the gas chromatograph. A review of the advantages and disadvantages of these instruments are presented here. The review also includes commercially unavailable technology such as the electronic nose and the Tunable Diode Laser (TDL) IR Spectrometer. It was found that the TDL could meet the majority of these criteria including fast response, minimum maintenance, portability, and reasonable cost. An experiment was conducted to demonstrate the feasibility of such a system using an existing (non-portable) instrument. A lead-salt tunable diode laser, cooled to 85 degrees Kelvin was used to record direct absorption and second-derivative spectra of Hydrazine at several pressures to study the sensitivity to low levels of Hydrazine. Spectra of NH3 and CO2 were used for wavelength identification of the scanned region. With a pathlength of 80 m, detection sensitivities of about 1 ppb were achieved for hydrazine in dry nitrogen at a cell pressure of 100 mbar. For spectroscopic detection of Hydrazine, spectral regions including strong Ammonia or Carbon Dioxide lines must be avoided. Strong Hydrazine absorption features were identified at 940/cm showing minimal contribution from Ammonia interferences as suitable candidates for Hydrazine gas detection. For the studies reported here, the particular laser diode could only cover the narrow regions near 962/cm and 965/cm where strong Ammonia interferences were expected. However, the high resolution (0.001/cm) of the TDL spectrometer allowed individual lines of Hydrazine to be identified away from interferences from either Ammonia or Carbon Dioxide, especially at lower pressures. A Hydrazine line was identified at 961.75/cm which was free from Ammonia absorption and would be suitable to monitor hydrazine levels. This paper also shows data on the degradation of the detectivity of Hydrazine with increasing pressure. Several design options for a portable unit are presented, including designs with near IR and Quantum Cascade laser components which do not require liquid nitrogen cooling.

Houseman, John

Empirical Line Parameters of NH(sub 3) from 4791 to 5294 cm(sup -1)

To support remote sensing of planetary atmospheres at 2??laboratory spectra of NH(sub 3) andf enriched (sup 14)NH(sub 3) and (sup 15)NH(sub 3) were recorded at 0.011 cm(sup -1) resolution with the McMath Fourier transform spectrometer (FTS) located at...

NH3 remote sensing planetary atmospheric study

Absolute absorption of ozone in the midinfrared

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1 percent using a Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared.

Pickett, H. M.

A facility for high resolution spectroscopy: Laboratory and ground based observations in support of upper atmospheric research

This research task consists of operating a facility for making spectroscopic observations in support of upper atmospheric research. The facility responds to the needs and interests of the visiting investigators. Therefore, the research objectives are not predetermined except in broad outline. The emphasis is on studies that take advantage of the particular strengths of the Fourier Transform Spectrometer on Kitt Peak: high spectral resolution combined with wide spectral range and low noise.

Brault, J. W.

Electrooptic phase modulation gas correlation spectroscopy - A laboratory demonstration

A new gas-correlation spectroscopy technique is described which uses electrooptic phase modulation (EOPM) of atmospheric emission spectra together with a reference cell to selectively detect radiatively active gases. Laboratory results demonstrate that the EOPM gas-correlation technique is a sensitive approach to species abundance measurements, and support the feasibility of an instrument for measurement of winds in the stratosphere and mesosphere using an EOPM. Through the measurement of wind-induced Doppler shifts in the spectra of atmospheric species, this instrument offers a means of monitoring the wind field in the 20-100 km altitude range from a satellite.

Rider, D. M.

Frequency-Modulation Correlation Spectrometer

New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.

Margolis, J. S.

Passive remote sensing of stratospheric and mesospheric winds

A passive infrared sensor for remote sounding of the wind field in the stratosphere and mesosphere from near earth orbital spacecraft is described. The sensor utilizes gas correlation spectroscopy and electrooptic phase-modulation techniques to measure winds in the 20-120 km altitude range, temperature, and atmospheric species concentrations. The operation of the sensor is examined. The sensitivity of the sensor is small Doppler shifts in an observed spectrum and the performance of the instrument were evaluated using laboratory simulation and numerical modeling. The data reveal that the sensor's wind measurements should have an accuracy better than 5 m/s and a spatial resolution of 5 km vertical by 150 km horizontal.

Mccleese, D. J.

Correlation spectrometer having high resolution and multiplexing capability

A correlation spectrometer permanently incorporates a reference cell and an electro-optical phase modulator (EOPM) in the light path between a sample cell and a detector. The effect of the EOPM is such that its frequency modulates all of the monochromatic component of the incoherent radiation passing through it. The EOPM is adjusted so that when it is ON all of the energy in the monochromatic components is thrown into sidebands differing from the original frequencies by integral multiples of the modulation frequency with the total amount of energy absorbed from the original radiation remaining constant. When there is no coincidence between the constituents in the two cells, the detector's output is the same when the EOPM is ON and when it is OFF. However, when there is coincidence the detector's output changes when the EOPM is switched between its two states. The change in the detector's output is related to the quantity of the constituents in the sample cell.

Margolis, J. S.

Obtaining Pulses From a CW Laser

Two acousto-optic modulators operate in tandem. System generates pulses from output of continuous wave laser. Duration and repetition rate of pulses controlled.

Margolis, J. S.

Measurements of Doppler shifts by gas correlation spectroscopy

IR gas correlation spectroscopy is a sensitive technique for the measurement of small Doppler shifts in spectra. This technique also exhibits several important advantages over alternative methods in the remote sensing of stratospheric and mesospheric winds from spacecraft. Attention is presently given to laboratory tests demonstrating gas correlation spectroscopy's quantitative measurement of small Doppler shifts in spectra, whose close agreement with theoretical predictions suggests that measurements of the change in the radiant flux through a gas correlation spectrometer can be used to measure the relative velocity between gas and instrument for a moving parcel of gas.

Mccleese, D. J.

Remote sensing of stratospheric and mesospheric winds by gas correlation electrooptic phase-modulation spectroscopy

A method is developed for directly measuring atmospheric winds in the 20-120 km altitude interval from a spacecraft. The wind sensor measures the Doppler shift between the spectral absorption lines of a gas in a cell within the instrument and the thermal emission lines of the same gas in the atmosphere. The wind measurements are performed using a spacecraft-borne gas correlation spectrometer viewing the limb of the atmosphere. The wind-induced Doppler shift between the two spectra, and thus the magnitude of the wind itself, is obtained by phase modulating the incoming thermal radiation (equivalent to frequency modulation) by means of an electrooptically active crystal to determine the frequency shift required to reestablish exact correlation between the lines in the cell and the lines from the atmosphere. Results of numerical simulations of the wind-sensor performance indicate that the noise-equivalent-wind is between 1-5 m/s over most of the stratosphere and mesosphere.

Mccleese, D. J.

N2 broadening parameters of ozone at 9.6 microns

Pressure-broadening coefficients were determined for 156 O3 absorption lines made with the Fourier-transform spectrometer at the McMath Solar Telescope of the Kitt Peak National Observatory in the 9-micron region, with a resolution of 0.005/cm. O3 prepared from O2 by silent arc discharge and collected on cold silica gel was held at stable concentrations over 50 percent in a glass or stainless-steel cell with a rock-salt window, and broadened with dry N2. Interferograms were made in several scans of the interferometer during 30 min. The pressure-broadening coefficients were calculated by an iterative least-squares approach, a synthetic spectrum was constructed and compared to the actual spectrum, and the parameters were varied to achieve the best fit. It is shown that the estimated precision of the values reported is about 7 percent, and that the deviation from the theoretical calculations of Tejwani and Yeung (1975) averaged 7.6 percent (a small number of large discrepancies having been excluded).

Margolis, J. S.

The ground state far infrared spectrum of NH3

The NH3 far infrared spectrum is particularly useful for the study of planetary composition and atmospheric dynamics. Studies of this spectrum were conducted by Dowling (1969), Helminger et al. (1971), and Urban et al. (1981). Sattler et al. (1981) have reported measurements of a few nu2 lines with tunable diode lasers. By using simple sum rules, these lines and accurate ground state inversion lines considered by Poynter and Kakar (1975) have been employed in the present investigation to deduce a few of the far infrared ground state transitions. An extensive set of high signal/noise, high resolution (0.0048 per cm) scans of the nu2 bands of NH3 from about 600 per cm through about 1300 per cm ait a series of low pressures have been made in order to accurately determine both the line positions and strengths. The obtained data provide line positions with an absolute accuracy of about 0.0001 per cm in the more favorable cases.

Poynter, R. L.